Cleaning; Daily; To Remove Salt And Amines Forma琀椀Ons; To Remove Esters Of 2, 4-D And Mcpa Forma琀椀Ons - Fast UT3P25 Owner's Manual

Utility sprayer
Table of Contents

Advertisement

Cleaning

Daily

At the end of the working day, clean the
system using this procedure:
1. After the chemical solution has been
completely sprayed out through the
booms, add 20 gallons (75 liters)
clear water to the tank.
2. Run the agitation pump for 5 minutes.
3. Spray the rinse lightly over previously
sprayed crop.
4. Clean the screen and nozzles.
5. Drain the tank and let it dry.
To
Remove
Salt
Formations
Perform this cleaning cycle when changing
chemicals and/or annually.
1. Follow
the
procedure
cleaning.
2. Remove all screens and nozzles and
wash them separately.
3. Add 50 gallons (200 liters) of clean
water to the tank.
4. Add 1/2 gallon (2 liters) of household
ammonia
to
ammonia to 100 parts water).
5. Run the agitation pump for 5 minutes.
6. Spray half of the solution out of the
booms.
7. Let the balance sit for a minimum of
8 hours; overnight is best.
8. Run the agitation pump for 10
minutes.
9. Spray solutions out of booms on the
appropriate crop.
10. Rinse the system thoroughly with
clean water and flush out the booms.
11. Drain the entire system and let it dry.
LUBRICATION & MAINTENANCE Utility Sprayer 25' / 30' / 40' / 45'
LUBRICATION & MAINTENANCE
and
Amines
for
daily
the
tank.
(1-part
To Remove Esters of 2, 4-D and MCPA
Formations
Perform this cleaning cycle when changing
chemicals or annually:
1. Complete the
daily
2. Remove the nozzles and screens
and wash them separately.
3. Add 50 gallons (200 liters) of clean
water to the- main tank.
4. Add dishwasher detergent to the tank
(2 lbs. detergent to 50 gallons of
water (1 kg:300 L)).
5. Run the agitation pump for 10
minutes.
6. Spray the solution out of the booms
on appropriate crops and drain
thoroughly.
7. Add 50 gal (200 L) of clean water to
the tank.
8. Add 1/2 gal. (2 L) of household
ammonia to the tank (1-part ammonia
to 100 parts water).
9. Run the agitation pump for 10
minutes.
10. Spray half of the solution out of the
booms.
11. Let the balance sit for a minimum of
8 hours; overnight is best.
12. Run the agitation pump for 10
minutes.
13. Spray out of the booms on the
appropriate crop.
14. Rinse the system thoroughly with
clean water and flush out the booms.
15. Drain the entire system and let it dry.