Open Center System (Open)
Select a motor size closest to tractor's
hydraulic system capacity. Regulate oil flow
with the motor NEEDLE VALVE.
(Do not use restrictor orifice or flow limiter.)
Figure 5: Closing the Needle Valve
Setup Instructions:
1. Shut off sprayer boom and agitation
valves.
2. Loosen jam nut on motor and back
out needle valve 3 or 4 turns
counterclockwise.
3. Set
tractor
throttle
operating speed.
4. Move
hydraulic
"Lower/Retract"
pump.
5. Screw needle valve clockwise until
sprayer
(deadhead)
within
the
parameters and lock the jam nut.
6. Open the sprayer agitation valve to
get desired injection pressure.
HYDRAULIC FLOW
to
sprayer
lever
to
position
to
start
pressure
is
pump's
operating
Utility Sprayer 25' / 30' / 40' / 45'
HYDRAULIC FLOW