Technical Data; General; Cu 800I, Cu 800I /460 - Fronius CU 1100i Operating Instructions Manual

Cooling unit
Hide thumbs Also See for CU 1100i:
Table of Contents

Advertisement

Technical data

General

The cooling capacity of a cooling unit depends on
-
-
-
CU 800i,
CU 800i /460 V
Mains voltage
Mains voltage tolerance
Grid frequency
Current consumption
Cooling capacity at
Q = 1 l/min + 25 °C (77 °F)
Q = 1l / min + 40 °C (104 °F)
Q = max. + 25 °C (77 °F)
Q = max. + 40 °C (104 °F)
Max. delivery head
Max. delivery rate
Max. pump pressure
Pump
Pump service life
Coolant capacity
Degree of protection
Dimensions l/w/h
Weight (without coolant)
Flow monitoring*
(sensor)
Coolant temperature monitoring*
Level sensor*
(functionality depends on the options
installed in the device)
Mark of conformity
Ambient temperature
Delivery head
Flow rate Q (l/min) - The flow rate Q depends on the length of the interconnecting
hosepack and the diameter of the hose.
Centrifugal pump
approx. 10,000 hrs
706/260/219 mm
27.8/10.24/8.62 in.
Warning between 1 and 0.7 l/min (0.26 -
error message below 0.7 l/min (0.18 gal./
Warning above 68 °C (154.4 °F),
error message above 70 °C (158 °F)
Warning or error message
CU 800i
400 V AC
-10% / +10%
50/60 Hz
0.7 A
800 W
500 W
1160 W
730 W
35 m
114 ft 9.95 in.
3.5 l/min
0.92 gal./min
4.2 bar
60.92 psi
4.5 l
1.19 gal.
IP 23
11.2 kg
24.69 Ib
0.18 gal./min),
min)
CE
63

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cu 800iCu 1400iCu 1100i /460 vCu 1100i /mvCu 1100i /mv rvpCu 1400i pro ... Show all

Table of Contents