Technical Data; General; Fk 4000 R, Fk 4000 R Fc - Fronius FK 4000 Operating Instructions Manual

Cooling unit
Table of Contents

Advertisement

Technical data

General

The cooling capacity of a cooling unit depends on
-
-
-
FK 4000
Mains voltage
Mains voltage tolerance
Mains frequency
Current consumption
Cooling power at
Q = 1 l/min + 25°C (77°F)
Q = 1 l/ min + 40°C (104°F)
Max. delivery head
Max. delivery rate
Max. pump pressure
Pump
Pump service life
Coolant quantity
Protection class
Dimensions l/w/h
Weight (without coolant)
Mark of conformity
FK 4000 R, FK
Mains voltage
4000 R FC
Mains voltage tolerance
Mains frequency
Current consumption
Cooling power at
Q = 1 l/min + 25°C (77°F)
Q = 1 l/ min + 40°C (104°F)
Max. delivery head
48
Ambient temperature
Delivery head
Flow rate Q (l/min) - The flow rate Q depends on the length of the interconnecting
hosepack and the diameter of the hose.
3 x 230 / 400 V AC
-10% / +10%
50 / 60 Hz
0.9 A / 0.6 A
1120 W
700 W
5 m
16 ft. 5 in.
1.6 l/min
0.42 gal./min [US]
4 bar
58 psi
Oscillating armature pump
approx. 3,000 hrs
5.5 l
1.45 gal. [US]
IP 23
725/290/230 mm
28.54/11.42/9.06 in.
14.1 kg
31.09 Ib.
CE
3 x 400 V AC
-10% / +10%
50 / 60 Hz
0.6 A
1360 W
870 W
33 m
108 ft. 3.24 in.