Before Installation And Commissioning; Safety; Setup Regulations - Fronius CU 1100i Operating Instructions Manual

Cooling unit
Hide thumbs Also See for CU 1100i:
Table of Contents

Advertisement

Before installation and commissioning

Safety

Danger due to incorrect operation and incorrectly performed work.
This can result in severe personal injury and damage to property.

Setup regulations

Danger from machines falling or toppling over.
This can result in serious injury and damage to property.
Danger from electric current.
An electric shock can be fatal.
The device is tested to IP 23 protection, meaning:
-
-
Cooling air
The system must be set up in such a way that the cooling air can flow unimpeded
through the slots in the side panels. Ensure that there is always an all-round clearance of
0.5 m (1 ft 7.69 in.) around the device.
Risk from insufficient cooling air supply.
This can result in serious damage to property.
Dust
Ensure that any metallic dust, for example from grinding work, is not sucked into the sys-
tem by the fan.
Outdoor operation
The device can be set up and operated outdoors in accordance with degree of protection
IP23. Avoid direct wetting (e.g. from rain).
WARNING!
All the work and functions described in this document must only be carried out and
used by trained and qualified personnel.
Fully read and understand this document.
Fully read and understand all the Operating Instructions for the system components,
especially the safety rules.
WARNING!
Place all system components on a solid, level surface in such a way that they
remain stable.
WARNING!
Ensure the cooling unit is properly insulated.
Always ensure that there is no electrically conductive connection between the base
plate of the cooling unit and the surface.
Before installing the cooling unit, remove all electrically conductive parts between
the base plate of the cooling unit and the surface.
Protection against penetration by solid foreign bodies with diameters > 12.5 mm
(0.49 in.)
Protection against spraywater at any angle up to 60° to the vertical
CAUTION!
Air inlets and outlets must never be covered, not even partially.