Opt Cu Coolant Filter; Opt/I Cu Level Sensor; Opt Cu Front Coolant Connections; Opt/I Cu Torch Deflate - Fronius CU 1100i Operating Instructions Manual

Cooling unit
Hide thumbs Also See for CU 1100i:
Table of Contents

Advertisement

OPT CU coolant
This option is available for all cooling units in the CU series.
filter
The coolant filter is equipped with a CrNi screen; its function is to filter dirt particles
above 100 micrometres in size from the coolant. This ensures that no coarse dirt
particles can pass into the coolant circuit. The coolant filter is fitted to the coolant return
connection on the cooling unit.
The option is included as standard on the CU 1100i /MV RVP cooling unit.
OPT/i CU level
This option is available with the following devices:
sensor
-
-
-
-
-
The option is included as standard on the CU 1400i Pro/MC cooling unit.
The level sensor monitors the level of coolant in the cooling unit.
If both the OPT/i CU flow temperature sensor and the OPT/i CU level sensor options
are installed in the cooling unit, the level sensor works as follows:
-
If just the OPT/i CU level sensor option is installed in the cooling unit, the level sensor
works as follows:
-
OPT CU front
This option is available for the following devices:
coolant connec-
-
tions
-
-
-
-
-
When the front coolant connection option is fitted, the cooling unit can be operated with
the following power sources:
-
-
-
OPT/i CU Torch
Function for emptying / filling the torch hosepack, e.g. when changing the torch body
deflate
The power source does not have to be switched off during this process.
This option is available for the following devices:
CU 800i, 1100i
CU 800i /460 V, 1100i /460 V
CU 1100i /MV
CU 1100i /MV RVP
CU 800i Pro, 1400i Pro
If the coolant drops below the minimum level:
the power source outputs a warning
the welding current is not interrupted
the cooling unit remains operational
If the coolant drops below the minimum level:
the power source outputs an error message
the level sensor interrupts the welding current
the cooling unit is switched off
CU 1100i
CU 1100i /460 V
CU 1100i /MV
CU 1100i /MV RVP
CU 1400i Pro
CU 1400i Pro /MC
TPS 320i C
TransTig 300i - 500i
MagicWave 300i - 500i
25