CU 1400i Pro,
If a TPS 320i C power source is used with a CU 1400i Pro or CU 1400i Pro /MC
CU 1400i Pro /MC
cooling unit, the cooling unit will not benefit from the maximum pump power.
Supply voltage
Current consumption
Cooling capacity at
Q = 1 l/min + 25 °C (77 °F)
Q = 1l / min + 40 °C (104 °F)
Q = max. + 25 °C (77 °F)
Q = max. + 40 °C (104 °F)
Max. delivery head
Max. delivery rate
Max. pump pressure at 4750 rpm
Pump
Pump service life
Coolant capacity
Degree of protection
Dimensions l/w/h
Weight (without coolant)
Flow monitoring*
(sensor)
Coolant temperature monitoring*
Level sensor*
(functionality depends on the options
installed in the device)
Mark of conformity
70
Centrifugal pump
27.95/11.81/9.06 in.
Warning between 1 and 0.7 l/min (0.26 -
error message below 0.7 l/min (0.18 gal./
Warning above 68 °C (154.4 °F),
error message above 70 °C (158 °F)
Warning or error message
CU 1400i Pro
24 V DC
4.4 A
1400 W
900 W
1700 W
1250 W
35 m
114 ft 9.95 in.
3 l/min
0.79 gal./min
4 bar
58.02 psi
up to 20,000 hrs
6 l
1.59 gal.
IP 23
710/300/230 mm
12 kg
26.46 Ib
0.18 gal./min),
min)
CE, CSA