Echo Dual Tech Wall-mount Occupancy Sensor
Overview
The Echo Dual Tech Wall-mount Occupancy Sensor uses passive infrared
(PIR) technology and acoustic detection to provide reliable occupancy and
vacancy sensing for lighting control.
Custom Configuration
This document guides you through the installation and local DIP switch
setup of the sensor. For more detailed information about custom
configuration options available using EchoAccess, see the EchoAccess
App integrated help system.
Note:
EchoAccess, DIP switch 2 must be enabled. See
page 7.
The wall-mount unit offers up to 140 degree field
of detection with optimized lens options to
accommodate wide or narrow angle spaces.
Wall-mount - Wide Angle Lens - coverage
• 18.3 m (60 ft) at mounting height of
• 140 degree field of detection
Wall-mount - Narrow Angle Lens - coverage
• 4.9x22.9 m (16x75 ft) at mounting height of
• 40 degree field of detection
See
Sensor Coverage on page 11
To use the configuration settings applied using
Corporate Headquarters n Middleton, WI, USA | +1 608 831 4116
Global Offices n London | Rome | Holzkirchen | Paris | Hong Kong | Dubai | Singapore
New York | Orlando | Los Angeles | Austin | © 2023 Electronic Theatre Controls, Inc.
Web
etcconnect.com
Contact
etcconnect.com/contactETC
Third-party license agreement
specifications subject to change. ETC intends this document to be provided in its entirety.
7186M2185 Rev C Released 2023-06
2.1–3 m (7–10 ft)
1.8–2.1 m (6–7 ft)
| Support
support.etcconnect.com
| Trademark and patent
info: etcconnect.com/licenses
.
DIP Switches on
info: etcconnect.com/ip
| Product information and

Advertisement

loading

Summary of Contents for ETC Echo Dual Tech

  • Page 1 Global Offices n London | Rome | Holzkirchen | Paris | Hong Kong | Dubai | Singapore New York | Orlando | Los Angeles | Austin | © 2023 Electronic Theatre Controls, Inc. etcconnect.com | Support support.etcconnect.com Contact etcconnect.com/contactETC | Trademark and patent info: etcconnect.com/ip Third-party license agreement info: etcconnect.com/licenses | Product information and specifications subject to change. ETC intends this document to be provided in its entirety. 7186M2185 Rev C Released 2023-06...
  • Page 2: Prepare For Installation

    (sold separately and available from ETC). Compliance • cULus Listed • CE compliant For use with ETC Echo Control Systems, powered by an Echo station power supply. Environment Ambient For indoor, commercial controls use only. Operating temperature 0°C–40°C (32°F–104°F), humidity maximum 90% (non-condensing).
  • Page 3: Wire Specification

    EchoConnect communication bus. EchoConnect is a bi-directional protocol that uses one pair of wires (data+ and data–) for both data and power. ETC recommends using Belden 8471 Class 2 wire (or approved equal – see the ETC cable cross database etcconnect.com/Support/Cable-...
  • Page 4: Installation

    ETC Installation Guide Dual Tech Wall-mount Occupancy Sensor Installation Note: NEC Class 2 product to be wired in accordance to NEC Article 725 and local jurisdiction requirements. The wall-mount sensor is provided with a mounting bracket with pre- routed wires that can be mounted to a back box. Follow the detailed instructions for installation.
  • Page 5 ETC Installation Guide Dual Tech Wall-mount Occupancy Sensor 4. Install the wall plate to the mounting plate. a. Align the top of the wall plate to the mounting plate, angling the bottom slightly. b. Hook the top of the wall plate to the tabs located on the mounting plate.
  • Page 6 ETC Installation Guide Dual Tech Wall-mount Occupancy Sensor Settings The Echo Dual Tech Wall-mount Occupancy Sensor participates in an Echo control system using the configured Space and Address, which are selectable using the rotary switches on the sensor electronics located behind the removable cover.
  • Page 7 ETC Installation Guide Dual Tech Wall-mount Occupancy Sensor DIP Switches DIP switches on the sensor electronics provide for additional configuration options including Use Custom Config, Vacancy Timeout, Enable/Disable detection LEDs, PIR Only Mode, and the ability to restore the sensor to its factory defaults.
  • Page 8: Operation

    ETC Installation Guide Dual Tech Wall-mount Occupancy Sensor Power Up All EchoConnect terminations in the system must be made before applying power to the system and sensor. When the sensor is powered, the PIR and acoustic detection LEDs illuminate for one minute for calibration and warm-up, and then return to normal operation according to the configuration.
  • Page 9 ETC Installation Guide Dual Tech Wall-mount Occupancy Sensor Program Mode Program Mode allows for local configuration of a sensor that is set for Basic configuration mode (DIP switch 2 set to Off). All basic configuration is set locally on the sensor using the other available DIP...
  • Page 10 ETC Installation Guide Dual Tech Wall-mount Occupancy Sensor Grace Period The sensor features a 30 second grace period after a vacancy timeout occurs. During this grace period, if the sensor detects occupancy, it will turn on or restore the previous lighting condition.
  • Page 11 ETC Installation Guide Dual Tech Wall-mount Occupancy Sensor Sensor Coverage Narrow Lens Top View 77° (16 ft) 21.5° 14° 2.5 m 29° (8 ft) 6.56° 2.5 m (8 ft) (16 ft) Side View 2.1 m (6.8 ft) 10.7 m 18.3 m 30.5 m...
  • Page 12 ETC Installation Guide Dual Tech Wall-mount Occupancy Sensor Wide Lens Top View 19.4° 10 m (33 ft) (16 ft) 140° (16 ft) 10 m (33 ft) Side View 2.1 m (6.8 ft) 7.7 m 4.6 m 15.3 m 1.7 m...