200 Hour Service; Ifp And Damper Body Service - SRAM RockShox SIDLuxe 2024+ Service Manual

Table of Contents

Advertisement

2 0 0 H o u r S e r v i c e
I F P a n d D a m p e r B o d y S e r v i c e
1
Wrap a shop towel around the end of the damper body. Thread the
SIDLuxe air valve adapter tool into a shock pump. Thread the pump
and adapter into the air fill port.
Pump air into the damper body to force the IFP out of the damper body
and into the shop towel.
RockShox SIDLuxe Air Valve Adapter Tool and shock pump
2
Clean the inside and outside of the damper body.
Remove a glove and use your finger to inspect the inside and outside
of the damper body for scratches, dents, or other surface deformations.
If any deformations are found, the damper body will need to be
replaced.
3
Remove and replace the IFP o-ring.
Apply grease and install the IFP o-ring.
45