Supermicro A+ Server AS -1115SV-WTNRT User Manual page 59

Table of Contents

Advertisement

Chassis Intrusion (JL1)
A Chassis Intrusion header is located at JL1 on the motherboard. Attach the appropriate cable
from the chassis to the header to inform you when the chassis is opened.
Overheat LED/Fan Fail (JOH1)
The JOH1 header is used to connect an LED indicator to provide warnings of chassis
overheating or fan failure. This LED will blink when a fan failure occurs. Refer to the tables
below for pin definitions.
IPMB System Management Bus Header (JIPMB1)
A System Management Bus header for IPMI 2.0 is located at JIPMB1. Connect the appropriate
cable here to use the IPMB I
Chassis Intrusion
Pin Definitions
Pins
Definition
1
Ground
2
Intrusion Input
Overheat / Fan Fail
Pin Definitions
Pins
Definition
1
5 VDC
2
OH Active
Overheat / Fan Fail
LED Status
Status
Definition
Off
Normal
On, Solid
Overheat
On, Blinking
Fan Failure
C connection on your system.
2
IPMB Header
Pin Definitions
Pin#
Definition
1
Data
2
Ground
3
Clock
4
No Connection