Evaporator plumbing
§ 3/8" OD push-in water inlet - 3/8" OD tubing required.
§ Water shut-off recommended within 10 feet (3 m).
§ Follett recommends installation of Follett water filter system (part# 00130286) in ice machine inlet water line.
Flush drain plumbing
§ 3/4" MPT flush drain connection at the rear of the machine.
§ Drain must slope 1/4" per foot (6 mm per 30,4 cm).
§ Drain line should not be shared with any other piece of equipment.
§ Drain line cannot be reduced to a size smaller than 1".
§ Drain should be piped without a vent.
2 ft. x 1" OD
silicone tubing
(6,4 mm per 0,3 m)
Chassis drain plumbing
§ Plug must be removed from John Guest fitting.
§ Route 3/8" drain tubing through knockout in back of docking station and insert fully into John Guest fitting
connection at the rear of the machine chassis. Route other end of 3/8" drain tubing to drain.
§ Drain must slope 1/4" inch per foot (6 mm per 30,4 cm).
Horizon Elite 1010/1410 Ice Machines (Remote Condensing)
3/4" barb x 3/4" FPT
3/4" MPT x 1" slip
1/4" per foot
1'
1" PVC Drain
Minimum 8"
radius
2 ft. x 1" OD
silicone tubing
3/4" barb x 3/4" FPT
3/4" MPT x 1" slip
1" Stand pipe/Drain