Emergency manual manoeuvre
(for model E MH / E LH only)
The model E MH / E LH is equipped with a mechanism
fitted in the motor head (fig. 7-f) which enables the us-
er to make an emergency manual manoeuvre by rotating
the rod in one direction or the other. To avoid premature
wear of the mechanism, it should be used exclusively in the
event of an emergency, such as a power failure.
Caution! – During this emergency manoeuvre, the
shutter must NOT exceed the travel limits "0" and "1"
set during product installation.
Product disposal
This product is an integral part of the automation and
therefore must be disposed together with the latter.
As in installation, also at the end of product lifetime, the
disassembly and scrapping operations must be performed
by qualified personnel.
This product comprises various types of materials: some
may be recycled others must be disposed of. Seek infor-
mation on the recycling and disposal systems envisaged
by the local regulations in your area for this product cat-
egory.
Caution! – some parts of the product may contain pollut-
ant or hazardous substances which, if disposed of into the
environment, may cause serious damage to the environ-
ment or physical health.
As indicated by the symbol alongside, dis-
posal of this product in domestic waste is
strictly prohibited. Separate the waste into
categories for disposal, according to the me-
thods envisaged by current legislation in your
area, or return the product to the retailer when purchasing
a new version.
Caution! – Local legislation may envisage serious fines in
the event of abusive disposal of this product.
What to do if...
(troubleshooting guide)
The motor does not move even if powered in an As-
cent or Descent phase:
1) check whether a thermal cut-out has tripped: In this
case wait for the motor to cool;
2) check that the mains power is ON and that it corre-
sponds to the values on the motor dataplate.
3) check whether the two limit switches, due to incorrect
settings, engage at the same time; in this case rotate
the two adjustment screws through a few turns, in the
direction of the "+" sign.
After these checks, if the motor still does not move,
contact a specialist technician or the Nice Assistance
Service.
Technical specifications
l Power supply voltage and frequency; current and
power; torque and speed: Refer to the technical data on
the dataplate of each model. l Motor diameter: 45 mm (E
S: 35 mm). l Nominal operating time: Maximum 4 min-
utes. l Protection rating: IP 44 (tubular motor). l Op-
erating temperature: -20°C (minimum). l Connection
cable length: 2.5 m.
Notes:
- All technical specifications stated in this section refer to
an ambient temperature of 20°C (± 5°C).
- Nice reserves the right to apply modifications to the
product at any time when deemed necessary, maintain-
ing the same intended use and functionality.
EC declaration of conformity
Nice S.p.A. hereby declares that the products: E S, E M,
E MH, E L, E LH, E Z M comply with the essential re-
quirements and other relevant provisions as established
by the directives 2006/95/CE, 2004/108/CE and 1999/5/
EC (applicable only to products with on-board receiver).
The CE declaration of conformity can be consulted and
printed out at the web site www.nice-ser vice.com or may
be requested from Nice S.p.A.
Ing. Mauro Sordini
(Managing Director)