SAFETY / CAUTIONS
TO REDUCE THE RISK OF ELECTRIC SHOCK, ENSURE ELECTRICITY HAS
•
BEEN TURNED OFF AT THE CIRCUIT BREAKER OR FUSE BOX BEFORE
BEGINNING.
ALL WIRING MUST BE IN ACCORDANCE WITH THE NATIONAL AND
•
LOCAL ELECTRICAL CODES. ELECTRICAL INSTALLATION SHOULD BE
PERFORMED BY A QUALIFIED LICENSED ELECTRICIAN.
WARNING: TO REDUCE THE RISK OF ELECTRIC SHOCK OR FIRE, DO
•
NOT USE THIS FAN WITH ANY SOLID-STATE FAN-SPEED CONTROL
DEVICE. IT WILL PERMANENTLY DAMAGE THE ELECTRONIC CIRCUITRY.
•
CAUTION: TO REDUCE THE RISK OF PERSONAL INJURY, USE ONLY THE
SCREWS PROVIDED WITH THE OUTLET BOX.
THE OUTLET BOX AND SUPPORT STRUCTURE MUST BE SECURELY
•
MOUNTED AND CAPABLE OF RELIABLY SUPPORTING A MINIMUM OF
50 LB (22.7 KG). USE ONLY UL-LISTED OUTLET BOXES MARKED "FOR FAN
SUPPORT."
•
THE FAN MUST BE MOUNTED WITH A MINIMUM OF 10' (3.05 M) FROM
THE TRAILING EDGE OF THE BLADES TO THE FLOOR.
•
AVOID PLACING OBJECTS IN THE PATH OF THE BLADES.
TO AVOID PERSONAL INJURY OR DAMAGE TO THE FAN AND OTHER
•
ITEMS, BE CAUTIOUS WHEN WORKING AROUND OR CLEANING THE
FAN.
DO NOT USE WATER OR DETERGENTS WHEN CLEANING THE FAN
•
OR FAN BLADES. A DRY DUST CLOTH WILL BE SUITABLE FOR MOST
CLEANING.
AFTER MAKING ELECTRICAL CONNECTIONS, SPLICED CONDUCTORS
•
SHOULD BE TURNED UPWARD AND PUSHED CAREFULLY UP INTO
THE OUTLET BOX. THE WIRES SHOULD BE SPREAD APART WITH THE
GROUNDED CONDUCTOR AND THE EQUIPMENT-GROUNDING
CONDUCTOR ON ONE SIDE OF THE OUTLET BOX AND THE
UNGROUNDED CONDUCTOR ON THE OTHER SIDE OF THE OUTLET BOX.
ALL SET SCREWS MUST BE CHECKED AND RE-TIGHTENED WHERE
NECESSARY BEFORE INSTALLATION.
4