Quatra 52" Ceiling Fan model no. 052-9329-2 Total weight of fan plus light kit are 7.4 kgs Instruction Manual Toll Free: 1-866-827-4985 IMPORTANT: Please read and understand this manual before any assembly. Before beginning assembly of product, make sure all parts are present. Compare parts with exploded view.
Toll Free: 1-866-827-4985 model no. 052-9329-2 IMPORTANT SAFETY INSTRUCTIONS Please read and save these instructions. Note: Always turn the power o · A dry dust cloth is suitable for most cleanings. · Should the ceiling fan become wet, have a qualified electrician inspect it before next use. ·...
TOOLS REQUIRED FOR ASSEMBLY After opening the package you should find all the necessary parts for installing this ceiling fan. The box should also include: Parts Pack containing: 3 balance pieces 2 wood screws with flat washers 2 5/32” screws with lock washers 1 balance clip 1 instruction sheet 3 wire connectors...
Page 6
Toll Free: 1-866-827-4985 model no. 052-9329-2 ASSEMBLY Installation: The installation is to be in accordance with the National Electrical Code, ANSI/NFPA 70 and local codes. 1. Mounting bracket Remove the canopy from the mounting bracket by removing Figure 1 the two mounting bracket screws and star washers from the Mounting bracket screw round holes in the canopy.
Page 7
ASSEMBLY 4. Wiring instructions WARNING ensure before wiring. Remote and Receiver Pairing Codes are set by pushing the location of the dip switches located on the transmitter and receiver up or down. It is important that the code used for both the remote and receiver are identical for the two devices to be able to communicate;...
Page 8
Toll Free: 1-866-827-4985 model no. 052-9329-2 aluminum ball Receiver Downrod Antenna: DO NOT CUT OR SPLICE After making the wire connections, the wires should be spread apart with the grounded conductor and the equipment-grounding conductor on one side of the outlet box and the ungrounded conductor on the other side of the outlet box.
OPERATION Remove the battery cover from the back of the remote control and insert 2 AA (fig.a) /9V batteries (fig.b)(included). Replace the battery cover. . Restore power to ceiling fan and test for proper operation. . The fan remote control controls the fan settings: LIGHT DIMMER ON/OFF...
Toll Free: 1-866-827-4985 model no. 052-9329-2 MAINTENANCE Because of the fan’s natural movement, some connections may become loose. Check the support connections, brackets and blade attachments twice a year. Make sure they are secure. There is no need to oil your fan. The motor has permanently lubric ated bearings. CARE AND CLEANING Dust your fan periodically with a soft, dry cloth.
3. Drop-mount and hands-free wiring TROUBLESHOOTING Problem Possible reason Solution Light does . Wires are not properly connected. . Ensure wire connector in switch not work housing is connected. Fan does . Fan is in reverse (blades are moving in .
Toll Free: 1-866-827-4985 model no. 052-9329-2 WARRANTY This Noma fan carries a llimited one (1) year warranty against defects in workmanship and materials. Noma agrees to replace the defective product free of charge within the stated warranty period, when returned by the original purchaser with proof of purchase. This product is not guaranteed against wear or breakage due to misuse and/or abuse.
Page 13
Ventilateur de plafond de 52 po Quatra N° de modèle : 052-9329-2 Poids total du ventilateur et de l'ensemble éclairage est de 7,4 kg Mode d’emploi Sans frais : 1 866 827-4985 IMPORTANT : Veuillez lire ce guide et bien le comprendre avant de commencer l’assemblage.
Page 14
Sans frais : 1 866 827-4985; modèle no 052-9329-2 ............................ 2 Table des matières Vue éclatée ............................ 3 Consignes de sécurité importantes ..................4 Règles relatives à l’installation sécuritaire ................4 Outils requis pour l’assemblage .....................5 Assemblage ...............................5 Utilisation ..............................9 Entretien ..............................10 Entretien et nettoyage ..........................10...
Page 15
VUE ÉCLATÉE Description Qté Non Description Qté Support de fixation Ensemble d’éclairage Tige Lames Toit Télécommande Couvercle de bride Récepteur Moteur...
Sans frais : 1 866 827-4985; modèle no 052-9329-2 CONSIGNES DE SÉCURITÉ IMPORTANTES Lisez et conservez les présentes instructions! Remarque : Toujours éteindre l’appareil avant de faire l’entretien du ventilateur de plafond. · Un chi on sec est le mieux adapté pour la plupart des nettoyages. ·...
OUTILS REQUIS POUR L’ASSEMBLAGE Après l’ouverture de l’emballage, vous devriez trouver toutes les pièces nécessaires pour l’installation de ce ventilateur de plafond. La boîte doit aussi comprendre : Paquet de pièces comprenant : 3 Pièces d’équilibrage 2 Vis à bois avec rondelles plates 2 Vis de 5/32 po avec rondelles 1 Pince d’équilibrage de blocage...
Page 18
Sans frais : 1 866 827-4985; modèle no 052-9329-2 ASSEMBLAGE Installation: L’installation doit être conforme au Code national de l’électricité, ANSI/NFPA 70 et avec les codes locaux. 1. Support de fixation Retirez le boîtier du support de montage en retirant les deux vis Image 1 et les rondelles en étoile du support de montage des trous ronds Vis du support...
Page 19
ASSEMBLAGE 4. Directives de câblage AVERTISSEMENT : Pour éviter les décharges électriques, assurez-vous que le courant est éteint au co ret de fusibles principal avant d’e ectuer le câblage. Jumelage de la télécommande et du récepteur Les codes peuvent être configurés en appuyant en haut ou en bas des commutateurs DIP situé sur l’émetteur et le récepteur.
Page 20
Sans frais : 1 866 827-4985; modèle no 052-9329-2 Entre le ventilateur et le récepteur : Branchez le fil noir portant la mention « L » du ventilateur au fil noir portant la mention « AU MOTEUR L » sur le récepteur. Branchez le fil bleu portant la mention «...
Page 21
FONCTIONNEMENT Retirez le couvercle du compartiment à piles au verso de la télécommande et insérez 2 piles AA (figure a) comprises/une pile 9 V (figure b) comprise. Replacez le couvercle du compartiment à piles. Activer et éteindre le ventilateur, et sélectionnez la vitesse Rallumez le courant au ventilateur de plafond et essayez-le pour vérifier le bon fonctionnement.
Sans frais : 1 866 827-4985; modèle no 052-9329-2 ENTRETIEN En raison du mouvement naturel du ventilateur, certaines connexions peuvent devenir lâches. Vérifiez les connexions de soutien, les supports et les pales deux fois par année. Assurez-vous qu’ils sont bien fixés. Nul besoin d’huiler votre ventilateur.
DÉPANNAGE Problème Cause possible Solution La lumière ne . Les fils ne sont pas correctement . Assurez-vous que le connecteur de fonctionne connectés. fils dans le boîtier de l’interrupteur pas. est connecté. Le ventilateur . Le ventilateur est en marche arrière .
Sans frais : 1 866 827-4985; modèle no 052-9329-2 GARANTIE Ce ventilateur Noma comprend une garantie de un (1) an contre les défauts de fabrication et de matériaux. Noma consent à remplacer l’article défectueux sans frais au cours de la période de garantie convenue lorsque l’article, accompagné...