13.3 Input/Output Connector Pin-Out Description
The sub-sections that follow give the connection details for all of the optional inputs and
output signals. Inputs are active High (12 VDC with a maximum current rating of 1 A). All
outputs are a dry contact relay type.
13.3.1 Input Base Connector ID
The input connector pins are identified in
Table 13-7
Input / A
Input / B
Input / C
Input / D
Input / E
Input / F
Input / G
Input / H
Input / J
Input / K
Input / L
13.3.2 Output Base Connector ID
The maximum loads on the digital outputs are as follows:
•
•
•
•
The output connector pins are identified in
Table 13-8
Output / A
Output / B
186
Input Base Connector Pins
Connector/Pin
Field Cable Wire Color
WHT
WHT/BLK
BLK
BLK/WHT
BLU
BLU/WHT
BLU/BLK
GRN
GRN/BLK
GRN/WHT
ORG
110 VDC / 0.3 A - 33 W
30 VDC / 2.0 A - 60 W
120 VAC / 0.5 A - 60 VA
240 VAC / 0.25 A - 60 VA
Output Base Connector Pins
Connector/Pin
Field Cable Wire Color
GRN
ORG/GRN
v 1.0 — February 2020
Table
13-7.
Remote standby
Remote boost
Remote start
Cooling lines not enabled
Manual boost
Remote Stop
12 V+
12 V+
0 V
0 V
Cycle Input
Table
13-8.
Alarm
Alarm
Altanium Delta5
Signal Function
Signal Function
Input/Output Connector Pin-Out Description