Cross-Talk Screen - Husky Altanium Delta5 User Manual

Table of Contents

Advertisement

User Guide
will show an X in the Wiring column. Also, the Re-Wire button on the Test Results screen will
be enabled.
To automatically rewire thermocouples, touch the Re-Wire button on the Diagnostics
Results screen. The system reassigns the mold thermocouples to their correct zones.
NOTE:
8.3

Cross-Talk Screen

Use the Cross-Talk screen to see how much heat transfer occurs between the zones in the
mold. Refer to
will show 100%, while all other zones will show 0%.
For example, Zone 9 completes the test and shows 100%, but Zone 10 shows 60%. If Zone 9
increased its temperature by 10
without added energy applied.
Figure 8-3
The column information of the Cross-Talk screen is described in
Table 8-4
Zone
Zone Name
Cross-Talk
Cross-Talk Screen
v 1.0 — February 2020
This rewire information is saved with the mold setup.
Figure
8-3. A zone in a correctly wired mold with no thermal isolation issues
Cross-Talk Screen
Cross-Talk Screen Column Information
Item
Shows the zone number.
Shows the name of the zone.
Shows the percentage of cross-talk between zones.
°
during the test, Zone 10 increased 60% of the 10
Description
Mold Diagnostics
°
, or 6
Table
8-4.
°
,
89