Work Modes - Energy I1000-RH1 Series User Manual

3kw / 3.68kw / 5kw / 6kw single phase, 2 mppts high voltage hybrid inverter
Table of Contents

Advertisement

6

3.2 Work modes

The I1000-RH1 series hybrid inverter has the following work modes based on your configuration
and layout conditions.
Work mode: Self-use
Priority: load>battery>grid
3
Self-consumption of PV renewable energy is the highest priority. The PV excess is used to
charge the batteries, then fed back into the grid.
Work mode: Feed in Pirority
Priority: load>battery>grid
This mode applies the area that has high feed-in tariff and export control.
The PV generated power will be used to supply the loads firstly, then feed into the grid.
The excess power will charge the battery.
4
1
4
2
1
Generated solar energy
2
Load consumption
3
Storage in battery
4
Feed the excess solar energy into the grid
1
3
2
1
Generated solar energy
2
Load consumption
3
Feed into grid
4
Charge the battery