8-3. Export Auxiliary Power Receptacles

3
1
120V 15/20A AC Receptacle GFCI1
Receptacles supply 60 Hz single-phase
power at weld/power speed.
If a ground fault is detected, GFCI1 Reset
button pops out and receptacle does not
work. Check for faulty tools plugged into re-
ceptacle. Press button to reset GFCI1.
.
At least once a month, run engine at
weld/power speed and press test but-
ton to verify GFCI is working properly.
Maximum output is 2.4 kVA/kW from GFCI1
and 4 kVa/kW from RC1.
Maximum combined output of all recep-
4
European Receptacle
Australian Receptacle
5
South African Receptacle
6
tacles is 4 kVA/kW.
EXAMPLE: If 13 A is drawn from RC1, only
7 A is available at GFCI1:
(240 V x 13 A) + (120 V x 7 A) =
4.0 kVA/kW
2
Circuit Breaker CB2
CB2 protects GFCI1 from overload. If a cir-
cuit breaker opens, the receptacle does not
work. Press CB2 to reset breaker.
3
Earth Leakage Circuit Breaker
ELCB1
ELCB1 protects RC1 from Earth leakage
fault. If circuit breaker opens the receptacle
1
238 127-A / 805 259-A
does not work. Place circuit breaker switch
in the On position to reset breaker.
.
At least once a month, press test but-
ton. If ELCB is working properly, power
will be disconnected. Reset breaker.
4
220V 16A AC European
Receptacle RC1
5
240 V 15 A AC Australian
Receptacle RC1
6
240 V 15 A AC South African
Receptacle RC1
.
If a circuit breaker continues to open,
contact Factory Authorized Service
Agent.
OM-4427 Page 43