Feature
Description
Two redundant power supply modules, PWS1 on the left and PWS2 on the right
Power Supplies
SYS-221HE-FTNR: 2000 W AC Power Supplies with PMBus
SYS-221HE-FTNRD: 1300 W DC Power Supplies with PMBus
USB
Two USB 3.0 ports
BMC LAN Port
One RJ45 dedicated BMC LAN port
VGA Port
One video port
Control Panel
One control panel (see
AIOM/OCP NIC 3.0 Slot
A1
A2
AIOM/OCP NIC 3.0 Slot
1 - PCIe 5.0 x16 Slot (FHFL 10.5") or PCIe 5.0 x8 (in x16) slot
2 - Optional: PCIe 5.0 x8 (in x16) slot (FHFL 10.5", slot 2 is disabled if slot 1 is configured as
PCIe 5.0 x16)
1
4
3 - PCIe 5.0 x16 Slot (FHFL 10.5") or PCIe 5.0 x8 (in x16) slot
4 - Optional: PCIe 5.0 x8 (in x16) slot (FHFL 10.5", slot 4 is disabled if slot 3 is configured as
PCIe 5.0 x16)
5 - PCIe 5.0 x16 Slot (FHFL 10.5") or PCIe 5.0 x8 (in x16) Slot
6 - Optional: PCIe 5.0 x8 (in x16) Slot (FHFL 10.5"). Slot 6 is disabled if slot 5 is configured
5
8
as PCIe 5.0 x16)
7 - PCIe 5.0 x8 (in x16) Slot (FHHL)
8 - PCIe 5.0 x8 (in x16) Slot (FHHL)
Note: FHFL = full height, full length, FHHL = full height, half length
Power Supply Condition
No Power to Power Supply
Power Supply critical events causing a
shutdown/ failure/ OCP/ OVP/ Fan Fail/
OTP/ UVP
Power Supply Warning Events Where the
power supply continues to operate; High
temperature; Over voltage; under voltage,
etc.
AC or DC present only 12VSB ON (PS
OFF)
Output ON and OK
One of the power cords unplugged and in
redundant mode
System Features: Rear
Control Panel
for details)
Power Supply Indicators
Green LED
OFF
OFF
OFF
1 Hz blinking
ON
OFF
11
Chapter 1: Introduction
Amber LED
OFF
ON
1 Hz blinking
OFF
OFF
ON