20-EMERGENCY PANEL FUNCTIONS

The emergency panel provides the following information:
through a multicolour LED (A) it provides information about the stove status (off-starting-up-in operation-cooling for shutdown- in
error conditions)
using the button (B) the following functions can be activated:
if the product triggered an error ----- reset the error by pressing the key for more than 3 seconds
Attention! Alarms A01, A02, A03, A05 and A21 can only be reset from the panel and not from the app.
if the product is off ------- switch it on (press the key for more than 3 seconds)
if the product has completed the ignition procedure (green LED on), press the key (briefly for 0.5 seconds) to change the power
according to this diagram:
LOW flame power 1 and ventilation level 1
MEDIUM flame power 3 and ventilation level 3
HIGH flame power 5 and ventilation level 5
Every time the power is changed, a buzzer will indicate the selected power on the stove:
1 beep LOW
3 beeps MEDIUM
5 beeps HIGH
If the product is running, switch it off by pressing the key for 3 seconds.
Attention! If the user erroneously presses the button for more than 10 seconds with the stove off, this will
automatically place the stove in download mode to update the firmware (operation restricted to an authorised
technician). This way, the stove remains in standby, with an intermittent buzzer, for a USB key containing the
firmware update. If a USB key is not inserted, the stove exits this mode after 10 seconds.