Table of Contents

Advertisement

EN
USE AND INSTALLATION MANUAL
8901155100

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Forma Wood 65 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for MCZ Forma Wood 65

  • Page 1 USE AND INSTALLATION MANUAL 8901155100...
  • Page 2: Table Of Contents

    5.3. INSTALLATION OF THE COMFORT AIR KIT..................... 29 Variation for air outlet with container ..................30 5.3.1. Variation for air outlet with illumination ..................30 5.3.2. Maintenance of air outlet with illumination ................31 5.3.2.1. Contents Technical service – MCZ S.p.A. all rights reserved - Reproduction prohibited...
  • Page 3 7.1.5.1. Control unit COMFORT AIR ....................45 7.1.5.2. Wiring..........................45 7.1.5.3. 7.2. CLEANING TO BE DEALT WITH BY SPECIALIZED TECHNICIAN ..............45 Cleaning flue pipe ........................45 7.2.1. Contents Technical service – MCZ S.p.A. all rights reserved - Reproduction prohibited...
  • Page 4: Introduction

    An essential item or one that requires specific attention is published in “bold”. “Italics"  are used for any additional clarification.  NOTE: the “NOTE” provides the reader with additional information on the subject. Introduction Technical service – MCZ S.p.A. all rights reserved - Reproduction prohibited...
  • Page 5: Warnings And Warranty Conditions

    If lost, please request a copy from your dealer or very hot (door, handle, glass). Therefore, avoid from MCZ. direct contact with these parts unless wearing protective clothing or specific means such as, for Warnings and warranty conditions Technical service – MCZ S.p.A. all rights reserved - Reproduction prohibited...
  • Page 6: Warranty Conditions

    The warranty is null and void in the event of damage due to tampering, weather, natural calamities, lightening, fire, defective electrical and hydraulic systems and the lack or incorrect maintenance as per the manufacturer's instructions. Warnings and warranty conditions Technical service – MCZ S.p.A. all rights reserved - Reproduction prohibited...
  • Page 7: Installation In Accordance With Uni 10683

    230V 50 Hz  equipped with an adequate smoke exhaust system  equipped with outdoor ventilation  provided with an earth connection complying with CEI Theoretical notions for installation Technical service – MCZ S.p.A. all rights reserved - Reproduction prohibited...
  • Page 8: Connection To The External Air Intake

    Theoretical notions for installation Technical service – MCZ S.p.A. all rights reserved - Reproduction prohibited...
  • Page 9: Connection To The Flue Pipe

    Theoretical notions for installation Technical service – MCZ S.p.A. all rights reserved - Reproduction prohibited...
  • Page 10: Examples Of Flue Pipes

    MCZ technician inspect and measure chimney flue performance (micro-gauge measurements) MCZ s.p.a. shall not be held liable for poor operation of the fireplace stove that is due to a flue pipe of improper size or installation that does comply with provided requirements.
  • Page 11: Cowl

    1 m over the obstacle and, in the event of other nearby cowls, keep them at least 2 m away. In any case, the cowl must exceed the peak of the roof by at least 1m. Theoretical notions for installation Technical service – MCZ S.p.A. all rights reserved - Reproduction prohibited...
  • Page 12: Dimensions And Technical Specifications

    Chapter 4 INSTALLATION AND USE MANUAL page 3. DIMENSIONS AND TECHNICAL SPECIFICATIONS Dimensions of the Forma Wood 65 3.1. 260 274 83.5 Installation and assembly Technical service – MCZ S.p.A. all rights reserved - Reproduction prohibited...
  • Page 13: Dimensions Of The Forma Wood 75

    Chapter 4 INSTALLATION AND USE MANUAL page Dimensions of the Forma Wood 75 3.2. 83.5 Installation and assembly Technical service – MCZ S.p.A. all rights reserved - Reproduction prohibited...
  • Page 14: Dimensions Of The Forma Wood 95

    Chapter 4 INSTALLATION AND USE MANUAL page Dimensions of the Forma Wood 95 3.3. 1056 275.5 256.5 83.5 Installation and assembly Technical service – MCZ S.p.A. all rights reserved - Reproduction prohibited...
  • Page 15: Dimensions Of The Forma Wood B95

    Chapter 4 INSTALLATION AND USE MANUAL page Dimensions of the Forma Wood B95 3.4. 578.5 1056 83.5 83.5 FRONTE RETRO Installation and assembly Technical service – MCZ S.p.A. all rights reserved - Reproduction prohibited...
  • Page 16: Dimensions Of The Forma Wood 115

    Chapter 4 INSTALLATION AND USE MANUAL page Dimensions of the Forma Wood 115 3.5. 1280 285.5 246.5 1048 150 100 1112 Installation and assembly Technical service – MCZ S.p.A. all rights reserved - Reproduction prohibited...
  • Page 17: Technical Specifications

    Intermittent combustion appliance * These data may vary according to the type of fuel used Tested according to EN 13229 in accordance with Directive 89/106/EC (Construction Products). Installation and assembly Technical service – MCZ S.p.A. all rights reserved - Reproduction prohibited...
  • Page 18 Intermittent combustion appliance * These data may vary according to the type of fuel used Tested according to EN 13229 in accordance with Directive 89/106/EC (Construction Products). Installation and assembly Technical service – MCZ S.p.A. all rights reserved - Reproduction prohibited...
  • Page 19 Intermittent combustion appliance * These data may vary according to the type of fuel used Testata secondo EN 13229 in accordo con la direttiva 89/106/CE (Prodotti da costruzione) Installation and assembly Technical service – MCZ S.p.A. all rights reserved - Reproduction prohibited...
  • Page 20: Installation And Assembly

    However, be sure to put all of the parts back in place. This operation is to be carried out only by specialized personnel. MCZ shall not be held liable if the preceding warning is not complied with. PREPARATION AND UNPACKING 4.1.
  • Page 21: Release Of Counterweights

    The fireplace stoves are self-supporting single-piece units that simplify installation and do not require any additional support. To make it easier to move the unit to its place of installation, MCZ provides four swivel castors that make moving the fireplace stove easy 5 cm min.
  • Page 22: Adjustment Of Height And Balancing

    Figure 3c – Safe distances CHECK THAT THE DOOR MOVES CORRECTLY SEVERAL TIMES BEFORE ENCLOSING THE FIREPLACE STOVE IN THE CLADDING. Installation and assembly Technical service – MCZ S.p.A. all rights reserved - Reproduction prohibited...
  • Page 23: External And Internal Air Intake

    Internal external intakes forced ventilation air. Figure 6 – Air intakes for ducts of fan and combustion air intake. Installation and assembly Technical service – MCZ S.p.A. all rights reserved - Reproduction prohibited...
  • Page 24: Connection To The Flue Pipe

    Dry install the fire bed of the cladding, leaving an aperture of 1 cm between the fireplace stove and the fire bed to provide insulation. (figure 8) Installation and assembly Technical service – MCZ S.p.A. all rights reserved - Reproduction prohibited...
  • Page 25: Insulating A Wooden Beam

    Grilles 1a and 1b are essential for releasing the heat that builds up in the hood. They must be installed, regardless of the type of installation or cladding to be realized. Installation and assembly Technical service – MCZ S.p.A. all rights reserved - Reproduction prohibited...
  • Page 26: Comfort Air Kit- Natural Ventilation And Forced Ventilation

    3. Hose Ø 100 L=1.5 m (2 pieces) lighting (2 pieces) 4. Flange Ø 100 VF (2 pieces) 2. Fastening bracket group (2 pieces) 5. Hose clamp D.60-170 (4 pieces) 6. Control unit Comfort air kit Technical service – MCZ S.p.A. all rights reserved - Reproduction prohibited...
  • Page 27: Accessories

    B – One-direction air outlet with illumination (includes light and container) C – Two-direction air outlet D – Multi-direction air outlet E - Natural ventilation air outlet structure for illumination + Fastening bracket group (2 pieces) Comfort air kit Technical service – MCZ S.p.A. all rights reserved - Reproduction prohibited...
  • Page 28: Air Outlets For Forced Ventilation Kit

    A – One-direction air outlet (includes container/without illumination) B – One-direction air outlet (includes container and illumination) C – Two-direction air outlet D – Multi-direction air outlet Comfort air kit Technical service – MCZ S.p.A. all rights reserved - Reproduction prohibited...
  • Page 29: Installation Of The Comfort Air Kit

     For both natural and forced ventilation, it is advisable to duct the front air outlets (A) where more heat accumulates than at the rear outlets (P). Figure 3 – Installation of hot air outlets Comfort air kit Technical service – MCZ S.p.A. all rights reserved - Reproduction prohibited...
  • Page 30: Variation For Air Outlet With Container

    If you install the comfort air kit with illumination, it is necessary to pre-install the light on the kit before inserting it in the hole. Figure 7-Lamp electrical connections Comfort air kit Technical service – MCZ S.p.A. all rights reserved - Reproduction prohibited...
  • Page 31: Maintenance Of Air Outlet With Illumination

    5. Put the container and door back in place. IMPORTANT! When you unscrew the screws to remove the glass, hold the glass with one hand; otherwise it will fall. Comfort air kit Technical service – MCZ S.p.A. all rights reserved - Reproduction prohibited...
  • Page 32: Control Unit

    All operations must be performed with the 230V 50 Hz mains power cord disconnected. Mcz shall not be held liable for damage to persons or things due to incorrect connections or improper use of the device.
  • Page 33: General Information On The Control Unit

    In this way, you will keep the room comfortable all night long. The next morning, the fire box will contain embers ready for a new load of wood or it will be out. Comfort air kit Technical service – MCZ S.p.A. all rights reserved - Reproduction prohibited...
  • Page 34: Safety Function

    All operations must be performed with the 230V 50 Hz mains power cord disconnected. Mcz shall not be held liable for damage to persons or things due to incorrect connections or improper use of the device.
  • Page 35: Installation Of Temperature Probe

    (12-11) DOOR OPEN SWITCH 5.7. On fireplace stoves of the “Wood” line, MCZ has installed a switch which, in the case of forced ventilation, must be connected to terminals 9-10 of the control unit, after removing the connection between the 2 terminals provided by the manufacturer.
  • Page 36: Connections

    Turn the knob right and left to test the various speeds. When connections are complete, install the selected air outlets. Comfort air kit Technical service – MCZ S.p.A. all rights reserved - Reproduction prohibited...
  • Page 37: Replacing The Fan

    All operations must be performed with the 230V 50 Hz mains power cord disconnected. Mcz shall not be held liable for damage to persons or things due to incorrect connections or improper use of the device Comfort air kit Technical service –...
  • Page 38: Operation

    (if kit COMFORT AIR VF is installed)  Light the fire at low power to ensure the smoke connections do not leak smoke or soot. Before lighting, however, read Chapter 6. Operation Technical service – MCZ S.p.A. all rights reserved - Reproduction prohibited...
  • Page 39: Choice Of Fuel

    Remove the stickers from the ceramic glass or the high temperature could melt them and irreparably damage the glass. In this case, the MCZ warranty does not cover the glass.  Completely open the front register of the combustion air using the provided hook.
  • Page 40: First Lighting

    As soon as the flames have died down and a bed of embers has formed, load the stove normally. Small loads of wood are preferable to large ones for combustion. Operation Technical service – MCZ S.p.A. all rights reserved - Reproduction prohibited...
  • Page 41: Loading The Fuel

    Nominal combustion has a duration of 50 min. Therefore, to obtain the nominal hourly loading set forth in the table in chapter 3, load the amount shown in parentheses in the table every 50 minutes. Operation Technical service – MCZ S.p.A. all rights reserved - Reproduction prohibited...
  • Page 42: Control Of Combustion

    If time allows, remove the grate and ashes, using a metal container.  Put the fire out rapidly by means of a dry carbon dioxide (CO extinguisher. Figure – Adjustment primary/secondary air. Operation Technical service – MCZ S.p.A. all rights reserved - Reproduction prohibited...
  • Page 43: Maintenance And Cleaning

     Flue pipe with poor performance which does not allow fireplace stove to reach high yield that results in adequate temperature of the refractory material. Maintenance and cleaning Technical service – MCZ S.p.A. all rights reserved - Reproduction prohibited...
  • Page 44: Lubrication And Routine Maintenance Of The Extensible Guides

    Clean the fan blades only with compressed air or with a vacuum cleaner. Take care not to damage the rotor or the fan blades. Maintenance and cleaning Technical service – MCZ S.p.A. all rights reserved - Reproduction prohibited...
  • Page 45: Control Unit Comfort Air

    To clean the appliance's chimney, remove the smoke deflector. To remove it correctly, lift the front and at the same time slide it forward in order to free it from rear support. Maintenance and cleaning Technical service – MCZ S.p.A. all rights reserved - Reproduction prohibited...
  • Page 46 MCZ GROUP S.p.A. Via La Croce n°8 33074 Vigonovo di Fontanafredda (PN) – ITALY Telephone: +39 0434/599599 PBX Fax: +39 0434/599598 internet: www.mcz.it e-mail: mcz@mcz.it 8901155100 Rev. 1 03/2013...

This manual is also suitable for:

Forma wood 75Forma wood 115Forma wood 95Forma wood b95

Table of Contents