Daikin Hubbard GCU2040PXB1 Installation, Commissioning And Maintenance Manual page 105

Table of Contents

Advertisement

ENG
Mask index
Display description
Aaan (display
Reg.var.
Enable
only)
Setpoint
Diff eren.
Mode
Status
...
...
Aaar (display
Reg.var.
Enable
only)
Setpoint
Diff eren.
Mode
Status
Aaas (display
Reg.variab.
Enable
only)
Setpoint
Diff eren.
Mode
Status
Aaat (display
Reg.variab.
Enable
only)
Setpoint
Diff eren.
Mode
Status
Aaau (display
Reg.variab.
Enable
only)
Type
Delay
Status
Aaav (display
Reg.variab.
Enable
only)
Type
Delay
Status
Aaaw (display
Day
F1: --:-- -> --:--
only)
...
F4: --:-- -> --:--
Status
Aaax (display
HR 1 Request:
HR 1 Status:
only)
Water temp.:
Valve:
Pump:
Pump An. Out:
Aaay (display
HR 2 Request:
HR 2 Status:
only)
Water temp.:
Valve:
Pump:
Pump An. Out:
Aaaz (display
Status
Ext.Temp.
only)
Thresh.est.t.
F.Time100%
Aaba (display
Status
Ext.Temp.
only)
Thresh.est.t.
F.Time100%
Aabb (display
Cond.Temp.
LiquidTemp
only)
Subcool
Status
Aabc (display
Cond.Temp.
LiquidTemp
only)
Subcool
Status
Ab01 (display
UserSetp.
only)
ActualSetp.
Diff .
Ab02 (display
UserSetp.
only)
ActualSetp.
Dead zone
Incr.Diff .
Decr.Diff .
Ab03 (display
UserSetp.
only)
ActualSetp.
Diff .
Ab04 (display
UserSetp.
only)
ActualSetp.
Dead zone
Incr.Diff .
Decr.Diff .
Copyright HPL March 2021
pRack PR300T +0300018EN rel. 1.5 - 02.05.2017
Description
Value of the regulation variable for the generic function in stage 1
Status of the enabling variable for the generic function in stage 1
Regulation setpoint for the generic function in stage 1
Regulation diff erential for the generic function in stage 1
Regulation mode for the generic function in stage 1 (direct or reverse)
Status of the generic function in stage 1
...
Value of the regulation variable for the generic function in stage 5
Status of the enabling variable for the generic function in stage 5
Regulation setpoint for the generic function in stage 5
Regulation diff erential for the generic function in stage 5
Regulation mode for the generic function in stage 5 (direct or reverse)
Status of the generic function in stage 5
Value of the regulation variable for generic modulating function 1
Status of the enabling variable for generic modulating function 1
Regulation setpoint for generic modulating function 1
Regulation diff erential for generic modulating function 1
Regulation mode for generic modulating function 1 (direct or reverse)
Status of generic modulating function 1
Value of the regulation variable for generic modulating function 2
Status of the enabling variable for generic modulating function 2
Regulation setpoint for generic modulating function 2
Regulation diff erential for generic modulating function 2
Regulation mode for generic modulating function 2 (direct or reverse)
Status of generic modulating function 2
Value of the regulation variable for generic alarm function 1
Status of the enabling variable for generic alarm function 1
Type of alarm for generic alarm function 1
Regulation diff erential for generic alarm function 1
Status of generic alarm function 1
Value of the regulation variable for generic alarm function 2
Status of the enabling variable for generic alarm function 2
Type of alarm for generic alarm function 2
Regulation diff erential for generic alarm function 2
Status of generic alarm function 2
Day of the week
Enabling and defi nition of time band 1: start hour and minute, end hour and minute for the
generic scheduling function
...
Enabling and defi nition of time band 4: start hour and minute, end hour and minute for the
generic scheduling function
Status of the general scheduling function
Percentage of fi rst heat reclaim request
Status of fi rst heat reclaim request
Water temperature with HR1 regulated by temperature
Status of fi rst heat reclaim valve
Status of fi rst heat reclaim pump
Running percentage of fi rst heat reclaim pump
Percentage of second heat reclaim request
Status of second heat reclaim request
Water temperature with HR2 regulated by temperature
Status of second heat reclaim valve
Status of second heat reclaim pump
Running Percentage of second heat reclaim pump
Status of the ChillBooster device (line 1)
External temperature (line 1)
Threshold for activating the ChillBooster device (line 1)
Number of minutes passed with fan at 100/number of minutes allowed (line 1)
Status of the ChillBooster device (line 2)
External temperature (line 2)
Threshold for activating the ChillBooster device (line 2)
Number of minutes passed with fan at 100/number of minutes allowed (line 2)
Condensing saturated temperature (line 1)
Liquid temperature (line 1)
Subcooling (line 1)
Status of the subcooling function (line 1)
Condensing saturated temperature (line 2)
Liquid temperature (line 2)
Subcooling (line 2)
Status of the subcooling function (line 2)
Setpoint set by the user for suction regulation under pressure, proportional regulation
(line 1)
Actual setpoint for suction regulation under pressure, proportional regulation (with
compensations applied, line 1)
Suction regulation under pressure diff erential, proportional regulation (line 1)
Setpoint set by the user for suction regulation under pressure, proportional regulation
(line 1)
Actual setpoint for suction regulation under pressure, proportional regulation (with
compensations applied, line 1)
Dead zone for suction regulation under pressure (line 1)
Increase diff erential for suction regulation under pressure, regulation in dead zone (line 1)
Decrease diff erential for suction regulation under pressure, regulation in dead zone (line 1)
Setpoint set by the user for suction regulation under pressure, proportional regulation
(line 2)
Actual setpoint for suction regulation under pressure, proportional regulation (with
compensations applied, line 2)
Suction regulation under pressure diff erential, proportional regulation (line 2)
Setpoint set by the user for suction regulation under pressure, proportional regulation
(line 2)
Actual setpoint for suction regulation under pressure, proportional regulation (with
compensations applied, line 2)
Dead zone for suction regulation under pressure (line 2)
Increase diff erential for suction regulation under pressure, regulation in dead zone (line 2)
Decrease diff erential for suction regulation under pressure, regulation in dead zone (line 2)
56
Page 105 of 172
Def.
U. of M.
Values
---
...
...(**)
---
---
Not active | Active
---
...
...(**)
---
...
...(**)
---
---
D, R
---
---
Not active | Active
...
...
...
---
...
...(**)
---
---
Not active | Active
---
...
...(**)
---
...
...(**)
---
---
D, R
---
---
Not active | Active
---
...
...(**)
---
---
Not active | Active
---
...
...(**)
---
...
...(**)
---
---
D, R
---
%
0.0...100.0
---
...
...(**)
---
---
Not active | Active
---
...
...(**)
---
...
...(**)
---
---
D, R
---
%
0.0...100.0
---
---
Not active | Active
---
---
Not active | Active
---
---
Normal | Serious
---
s
0...9999
---
---
Not active | Active
---
---
Not active | Active
---
---
Not active | Active
---
---
Normal | Serious
---
s
0...9999
---
---
Not active | Active
---
---
Monday, ..., Sunday
---
...
...
...
...
...
---
...
...
---
---
Not active | Active
%
ON | OFF
°C/°F
Open | Closed
ON | OFF
%
%
ON | OFF
°C/°F
Open | Closed
ON | OFF
%
---
---
ON | OFF
---
...
...(**)
---
...
...(**)
---
min
0...999 | 0...999
---
---
ON | OFF
---
...
...(**)
---
...
...(**)
---
min
0...999 | 0...999
---
...
...(**)
---
...
...(**)
---
...
...(**)
---
---
Open | Closed
---
...
...(**)
---
...
...(**)
---
...
...(**)
---
---
Open | Closed
---
...
...(**)
---
...
...(**)
---
...
...(**)
---
...
...(**)
---
...
...(**)
---
...
...(**)
---
...
...(**)
---
...
...(**)
---
...
...(**)
---
...
...(**)
---
...
...(**)
---
...
...(**)
---
...
...(**)
---
...
...(**)
---
...
...(**)
---
...
...(**)
P4114S Rev 03