Summary of Contents for BLAUBERG VENTO Expert A50C3-1 S8 W V.2

  • Page 1 Single-room reverSible energy recovery ventilator vento expert a50c3-1 S8 W v.2 USER’S MANUAL...
  • Page 2: Table Of Contents

    The manual contains information about purpose, technical details, operating principle, design, and installation of the VENTO Expert A50C3-1 S8 W V.2 unit and all its modifications. Technical and maintenance staff must have theoretical and practical training in the field of ventilation systems and should be able to work in accordance with workplace safety rules as well as construction norms and standards applicable in the territory of the country.
  • Page 3 S8 W v.2 www.blaubergventilatoren.de The appliance may adversely affect the safe operation of appliances burning gas or other fuels (including those in other rooms) due to back flow of combustion gases. These gases can potentially result in carbon monoxide poisoning. After installation of the unit the operation of flued gas appliances should be tested by a competent person to ensure that back flow of combustion gases does not occur.
  • Page 4: Purpose

    S8 W v.2 www.blaubergventilatoren.de PURPOSE The ventilator is designed to ensure continuous mechanical air exchange in flats, cottages, hotels, cafés and other domestic and public premises. The ventilator is equipped with a regenerator that enables supply of fresh filtered air heated by means of extract air heat energy recovery.
  • Page 5: Technical Data

    S8 W v.2 www.blaubergventilatoren.de TECHNICAL DATA The ventilator is rated for indoor application with the ambient temperature ranging from -30 °C up to +40 °C and relative humidity up to 65 %. The unit is rated as a class II electric appliance.
  • Page 6: Design And Operating Principle

    S8 W v.2 www.blaubergventilatoren.de The technical data of the specific model are indicated on the label on the ventilator casing. DESIGN AND OPERATING PRINCIPLE The ventilator consists of an indoor unit with a decorative front panel, a cartridge, an air duct with a sound absorbing layer and an outer ventilation hood.
  • Page 7 (“Party mode”) (4 hours by default). If necessary, in the “Schedule of the Blauberg Home mobile application” section, you can set different speeds of the ventilator at different time intervals by day of the week. For the weekly schedule to work correctly, you must set the current date and time correctly in the “Date and time”...
  • Page 8: Mounting And Set-Up

    S8 W v.2 www.blaubergventilatoren.de MOUNTING AND SET-UP READ THE USER'S MANUAL BEFORE INSTALLING THE UNIT. DO NOT BLOCK THE AIR DUCT OF THE INSTALLED VENTILATOR WITH DUST ACCUMULATING MATERIALS, SUCH AS CURTAINS, CLOTH SHUTTERS, ETC. AS IT PREVENTS AIR CIRCULATION IN THE ROOM.
  • Page 9 S8 W v.2 www.blaubergventilatoren.de 3. Stick the delivered cardboard master plate on the indoor wall using a mounting tape. The large opening in the master plate must be axially aligned with the air duct. For aligning the master plate with respect to the horizon line it is recommended to use a builder’s level.
  • Page 10 S8 W v.2 www.blaubergventilatoren.de 7. Install the cartridge into the air duct as figured below. Be sure the pointer is directed upwards. Then fix the wire with the retaining clip and connect the connector to the circuit board.
  • Page 11: Connection To Power Mains

    S8 W v.2 www.blaubergventilatoren.de CONNECTION TO POWER MAINS POWER OFF THE POWER SUPPLY PRIOR TO ANY OPERATIONS WITH THE UNIT. THE UNIT MUST BE CONNECTED TO POWER SUPPLY BY A QUALIFIED ELECTRICIAN. THE RATED ELECTRICAL PARAMETERS OF THE UNIT ARE GIVEN ON THE MANUFACTURER’S LABEL.
  • Page 12 S8 W v.2 www.blaubergventilatoren.de PRE-SETTING OF THE VENTILATOR Prior to operating the ventilator set it up using the DIP switch. It is located on the controller circuit board. To access the DIP switch, take off the front panel of the indoor unit and uplift the rubber plug that covers the switch.
  • Page 13 S8 W v.2 www.blaubergventilatoren.de The figure below shows the control buttons on the indoor unit and the remote control with a brief description of their function. Speed/Standby Turning ventilator on/off The speed selection sequence is follows: I-II-III-Standby.
  • Page 14 S8 W v.2 www.blaubergventilatoren.de VENTILATOR CONTROL WITH THE BUTTONS ON THE INDOOR UNIT The table below shows the buttons and indicators on the indoor unit of the ventilator with a detailed description of their purpose and functionality.
  • Page 15 Press any speed setting key to deactivate the timer or press the timer control button once again. REMOTE CONTROL OF THE VENTILATOR WITH A BLAUBERG HOME APP Download the Blauberg Home application and install it on the mobile device. Blauberg Home – App Store Blauberg Home –...
  • Page 16 S8 W v.2 www.blaubergventilatoren.de WIRELESS CONNECTION OF SEVERAL VENTILATION UNITS The ventilators can be combined into a group in which one ventilator acts as a Master device and the others are connected to it as Slaves. If the ventilator is a Master unit, Slave units and mobile devices connect to it via Wi-Fi. The Master unit is operated by means of a mobile device, the remote control or the touch buttons on the unit casing.
  • Page 17 S8 W v.2 www.blaubergventilatoren.de VENTILATOR WIRELESS CONNECTION DIAGRAMS Wiring diagram 1 Connection of up to 8 Slave units or mobile devices to the Master unit with its own wireless Master with a Wi-Fi access point access point.
  • Page 18 Set the DIP switches on each ventilator to the position that corresponds to its role in the group (see “DIP switch position”). • Then configure the Wi-Fi settings of the Master ventilator by following the instructions in the Blauberg Home mobile app. •...
  • Page 19: Technical Maintenance

    S8 W v.2 www.blaubergventilatoren.de TECHNICAL MAINTENANCE DISCONNECT THE UNIT FROM POWER SUPPLY BEFORE ANY MAINTENANCE OPERATIONS! MAKE SURE THE UNIT IS DISCONNECTED FROM POWER MAINS BEFORE REMOVING THE PROTECTION Maintenance of the ventilator means regular cleaning of the ventilator surfaces of dust and cleaning and replacement of the filters. To enable access to the main units, follow the procedure described below.
  • Page 20 S8 W v.2 www.blaubergventilatoren.de 3. Pull the cord to remove the cartridge from the air duct. Clean the filters as they get clogged, but not less than once in three months. • Upon elapse of the set time period (factory setting 90 days) the filter replacement indicator (Filter) starts glowing. The filter timer is reset using the program on the mobile device.
  • Page 21: Storage And Transportation Regulations

    S8 W v.2 www.blaubergventilatoren.de POSSIBLE REASONS AND TROUBLESHOOTING Problem Possible reasons Troubleshooting Make sure the power supply line is connected No power supply. correctly, otherwise troubleshoot the connection When switching on the error. ventilator, the fan does not Turn the ventilator off.
  • Page 22: Manufacturer's Warranty

    S8 W v.2 www.blaubergventilatoren.de MANUFACTURER’S WARRANTY The product is in compliance with EU norms and standards on low voltage guidelines and electromagnetic compatibility. We hereby declare that the product complies with the provisions of Electromagnetic Compatibility (EMC) Directive 2014/30/EU of the European Parliament and of the Council, Low Voltage Directive (LVD) 2014/35/EU of the European Parliament and of the Council and CE-marking Council Directive 93/68/EEC.
  • Page 23: Certificate Of Acceptance

    S8 W v.2 www.blaubergventilatoren.de CERTIFICATE OF ACCEPTANCE Unit Type Single-room reversible energy recovery ventilator Model Serial Number Manufacture Date Quality Inspector’s Stamp SELLER INFORMATION Seller Address Phone Number E-mail Purchase Date This is to certify acceptance of the complete unit delivery with the user’s manual. The warranty terms are acknowledged and accepted.
  • Page 24 www.blaubergventilatoren.de B133-6EN-02...