PERFORMANCE DATA

At reference conditions, if applicable, and at normal shaft speed, unless otherwise stated.
Designation
Engine shaft speed, normal and maximum
Engine shaft speed, compressor unloaded
1)
Free air delivery
Fuel consumption
-at 90% Load
-at 75% Load
- Not Loaded Idle
- Compressed air temperature at outlet valve
- Compressed air temperature at outlet valve
2)
Noise level
1)
The international standard ISO 1217 corresponds to the following national standard:
2)
Free air delivery is measured according to ISO 1217 ed. 3 1996 annex D
Tolerance:
• +/- 5% 25 l/s < FAD < 250 l/s
• +/- 4% 250 l/s < FAD
- American ANSI PTC9
- British BSI 1571 part 1
The international standard ISO 1217 corresponds to the following national standard:
- American ANSI PTC9
- British BSI 1571 part 1
- German DIN 1645 part 1
- Swedish SS-ISO 1217
rpm
rpm
l/s
cfm
gal/h
gal/h
gal/h
°C
°F
°C
°F
dB(A)
3)
Gross power guaranteed within +/- 5% at SAE J1995 and ISO 3046 conditions:
- 77°F air inlet temperature
- 29.31 in. Hg barometer
- 104 °F fuel inlet temperature
- 0.853 fuel specific gravity @ 60 °F
4)
Depending on Ambient Temperature
- 78 -
XRVS 1000
1950
1300
472
1000
20.71
12.59
3.39
82.3
180
37.8
100
76