Stopping - Atlas Copco XRVS 1000 CD7 IT4 HOP Instruction Manual

Table of Contents

Advertisement

Set the Pressure/Flow Setpoint
When the controller is in the Main View (shift between
PRESSURE and FLOW VIEW with right/left arrows):
MAIN VIEW
LOADED
18.6
41%
1286h
1800RPM
Press ENTER for 2 seconds, and the middle section
becomes green (setting can be edited)
MAIN VIEW
LOADED
18.6
41%
1286h
1800RPM
Press the UP/DOWN arrows to set the requested pressure/
flow.
Press ENTER to confirm the new setting.
Some additional control features are available from Atlas
Copco, such as dual pressure switch, remote start, auto
start, remote pressure setting. If interested, please consult
your Atlas Copco representative for more information.

STOPPING

After pressing the STOP button the display will show:
MAIN VIEW
ENGINE COOLING DOWN
Press ENTER to allow DPF regen before stop
DPF Soot Load level 50
41%
18.6bar
After a Stop command, or in case of a controlled stop
alarm, the machine will cool down and run at minimum
rpm for 3 minutes before it will stop.
If the Soot Load in the diesel particulate filter is above
30% when a stop command is given, the controller will ask
the user if it is allowed to perform a complete DPF
Regeneration cycle before stopping.
A full DPF Regeneration can take up to an
hour.
When ENTER is pressed the HEST icon will appear:
See paragraph Always first shut off the controller and wait
18.6bar
until the display is dark before switching the battery
switch to position "OFF".Diesel Particulate Filter
Regeneration.
0s
180s
1s
1286h
1200RPM
19.4bar
HEST Icon
- 38 -
MAIN VIEW
ENGINE COOLING DOWN
0s
180s
84s
41%
1286h
1200RPM
6.0bar
Active Buttons
Start Button
(to initiate Start command)
Measurement View Button
Settings View Button
Alarms View Button