Montigo Divine H34VO E Series Installation & Maintenance Manual page 6

Outdoor residential gas fireplace
Hide thumbs Also See for Divine H34VO E Series:
Table of Contents

Advertisement

Divine Outdoor Gas Fireplace
Section 2: Framing
Choosing The Fireplace Location
The Divine Outdoor VO may be installed in an outdoor setting such as
a patio or balcony. Choose a location that maintains proper clearance
to combustibles as noted in the clearances chart.
Note: Divine Outdoor VO may not be recessed into the exterior wall.
Note: Minimum 2 side of the covered patio/deck must be open
Figure 2. Choosing the fireplace location.
For protection against freezing temperatures, it is recommended that
outer walls of the chase be insulated with a vapour barrier. This will
reduce the possibility of a cold-air convection current on the fireplace.
Page 6
Installation
Installation
Exterior Wall
B
A
M"
Figure 2.a Minimum framing dimensions.
** Optiona l Drain Pan:
available for all models.
H34VO Part No. OD34123
A
H38VO Part No. OD38123
H42VO Part No. OD42123
H34VO
383/4
353/8
H38VO
421/2
H42VO
461/2
Be sure to plan a drain system for both in the wall and standalone installations.
*Measurement above grade for US installations
Dimension is to back wall or back studs
Top View
*Clearance to grade
12" clearance to grade applies in situations where the fireplace and framing
penetrates the building envelope. Additionally, if snow accumulation may
occur, than the 12" clearance should be adhered to.
C
D
This 12" clearance can be disregarded in situations where:
• A standalone enclosure has been built or purchased.
• The fireplace and framing does not penetrate the building envelope.
• Covered porches with overhang that prevents weather from contacting
D
the fireplace wall.
12"*
If local codes states a clearance greater than the one listed here, than revert
to local code clearance.
I
A
Front View
B
C
D
B
C
D
E
N"
201/4
12*
615/8
353/8
O"
391/4
213/8
12*
657/8
391/4
431/2
223/8
12*
721/4
431/2
H
G
A
D
F
E
B
F
Side View
Back wall
with insulation
material vapor
barrier (exterior
wall)
Insulation material
vapor barrier
(exterior wall).
Q"
F
G
H
0
435/8
0
499/16
0
519/16
G
J
XG0150 - 140707.2

Advertisement

Table of Contents
loading

Table of Contents