  • Page 1 USER USER ECX-3000 PEG Manual Manual 13th/12th Gen Intel ® Core™ i9/i7/i5/i3 AI Computing System Workstation-grade, NVIDIA ® /AMD Graphics, 4 PCIe 1.1.0 Edition 20230908...
  • Page 2 Record of Revision Version Date Page Description Remark 1.00 2023/5/29 Official Release 1.10 2023/9/8 28, 33 Update ©Vecow ECX-3000 PEG User Manual...
  • Page 3 This manual is released by Vecow Co., Ltd. for reference purpose only. All product offerings and specifications are subject to change without prior notice. Vecow Co., Ltd. is under no legal commitment to the details of this document. Vecow shall not be liable for direct, indirect, special, incidental, or consequential damages arising out of the use of this document, the products, or any third party infringements, which may result from such use.
  • Page 4 SSD trays, 1 PCIe x16, 6 USB 3.2, 1 USB Type C, 4 COM, 32 Isolated DIO, 1 System Fan ECX-3100-PEG, 2 GigE LAN, 2 Front-access SSD trays, 1 PCIe ECX-3100-PEG x16, 6 USB 3.2, 1 USB Type C, 4 COM, 16 GPIO, 1 System Fan ©Vecow ECX-3000 PEG User Manual...
  • Page 5 CPU List Series Cores TDP (W) ECC RAM i9-13900E i9-13900TE i7-13700E i7-13700TE i5-13500E i5-13500TE i3-13100E i3-13100TE ® ™ Intel Core i9-12900E i9-12900TE i7-12700E i7-12700TE i5-12500E i5-12500TE i3-12100E i3-12100TE ©Vecow ECX-3000 PEG User Manual...
  • Page 6 VESA Mount VESA Mounting Kit M.2 Storage Module M.2 Key M/Key B PCIe Storage Module 5G Module 5G Module with Antenna 4G Module 4G/GPS Module with Antenna WiFi & Bluetooth WiFi & Bluetooth Module with Antenna ©Vecow ECX-3000 PEG User Manual...
  • Page 7: Table Of Contents

    1.5.3 Dimensions of ECX-3400 PEG 1.5.4 Dimensions of ECX-3200MX PEG 1.5.5 Dimensions of ECX-3200 PEG 1.5.6 Dimensions of ECX-3100 PEG CHAPTER 2 GETTING TO KNOW YOUR ECX-3000 PEG 2.1 Packing List 2.1.1 ECX-3800 PEG Packing List 2.1.2 ECX-3600 PEG Packing List 2.1.3 ECX-3400 PEG Packing List...
  • Page 8 4.6 Boot Menu 4.7 Save & Exit APPENDIX A : Isolated DIO/GPIO Guide APPENDIX B : Software Functions APPENDIX C : RAID Functions APPENDIX D : Power Consumption APPENDIX E : Supported Memory & Storage List ©Vecow ECX-3000 PEG User Manual viii...
  • Page 9: Chapter 1 General Introduction

    ECX-3600 PEG, ECX-3400 PEG, ECX-3200MX PEG, ECX-3200 PEG and ECX-3100 PEG. The ECX-3000 PEG packs a variety of LAN ports including 2.5G, 2.5G PoE+, 2.5G PoE+ with X-Coded M12 and GigE LAN, and supports high-speed data transfer up to 20G through USB 3.2 Gen 2x2. With up to 4 PCIe expansion slots, support for DDR5 4800MHz memory up to 64GB, the ECX-3000 PEG offers a robust combination of performance and flexibility to facilitate AIoT applications.
  • Page 10: Features

    • 4 Independent 2.5G LAN with 4 IEEE 802.3at PoE+ ® • 5G/WiFi/BT/4G/LTE/GPRS/UMTS, Supports Intel vPro, TCC, Time-Sensitive Networking (TSN), and TPM 2.0 • Storage : Max. 4 front-access 2.5" SSD Tray, M.2 Key M ©Vecow ECX-3000 PEG User Manual GENERAL INTRODUCTION...
  • Page 11: Product Specification

    4 SATA III (6Gbps) support S/W RAID 0, 1, 5, 10 1 M.2 Key M Socket (2280, PCIe x4) Storage Device 4 Front-access 2.5" SSD/HDD Tray Audio ® Audio Codec Realtek ALC888S-VD, 7.1 Channel HD Audio Audio Interface 1 Mic-in, 1 Line-out ©Vecow ECX-3000 PEG User Manual GENERAL INTRODUCTION...
  • Page 12 Operating Temperature -20°C to 45°C (-4°F to 113°F), with System Fan Storage Temperature -40°C to 85°C (-40°F to 185°F) Humidity 5% to 95% humidity, non-condensing Relative Humidity 95% at 45°C Shock /Vibration Operating, MIL-STD-810G, Procedure I CE, FCC, EN50155, EN50121-3-2 ©Vecow ECX-3000 PEG User Manual GENERAL INTRODUCTION...
  • Page 13: Specifications Of Ecx-3600 Peg

    4 SATA III (6Gbps) support S/W RAID 0, 1, 5, 10 1 M.2 Key M Socket (2280, PCIe x4) Storage Device 4 Front-access 2.5" SSD/HDD Tray Audio ® Audio Codec Realtek ALC888S-VD, 7.1 Channel HD Audio Audio Interface 1 Mic-in, 1 Line-out ©Vecow ECX-3000 PEG User Manual GENERAL INTRODUCTION...
  • Page 14 Operating Temperature -20°C to 45°C (-4°F to 113°F), with System Fan Storage Temperature -40°C to 85°C (-40°F to 185°F) Humidity 5% to 95% humidity, non-condensing Relative Humidity 95% at 45°C Shock /Vibration Operating, MIL-STD-810G, Procedure I CE, FCC, EN50155, EN50121-3-2 ©Vecow ECX-3000 PEG User Manual GENERAL INTRODUCTION...
  • Page 15: Specifications Of Ecx-3400 Peg

    4 SATA III (6Gbps) support S/W RAID 0, 1, 5, 10 1 M.2 Key M Socket (2280, PCIe x4) Storage Device 4 Front-access 2.5" SSD/HDD Tray Audio ® Audio Codec Realtek ALC888S-VD, 7.1 Channel HD Audio Audio Interface 1 Mic-in, 1 Line-out ©Vecow ECX-3000 PEG User Manual GENERAL INTRODUCTION...
  • Page 16 Operating Temperature -20°C to 45°C (-4°F to 113°F), with System Fan Storage Temperature -40°C to 85°C (-40°F to 185°F) Humidity 5% to 95% humidity, non-condensing Relative Humidity 95% at 45°C Shock /Vibration Operating, MIL-STD-810G, Procedure I CE, FCC, EN50155, EN50121-3-2 ©Vecow ECX-3000 PEG User Manual GENERAL INTRODUCTION...
  • Page 17: Specifications Of Ecx-3200Mx Peg

    2 SATA III (6Gbps) support S/W RAID 0, 1 1 M.2 Key M Socket (2280, PCIe x4) Storage Device 2 Front-access 2.5" SSD/HDD Tray Audio ® Audio Codec Realtek ALC888S-VD, 7.1 Channel HD Audio Audio Interface 1 Mic-in, 1 Line-out ©Vecow ECX-3000 PEG User Manual GENERAL INTRODUCTION...
  • Page 18 Operating Temperature -20°C to 45°C (-4°F to 113°F), with System Fan Storage Temperature -40°C to 85°C (-40°F to 185°F) Humidity 5% to 95% humidity, non-condensing Relative Humidity 95% at 45°C Shock /Vibration Operating, MIL-STD-810G, Procedure I CE, FCC, EN50155, EN50121-3-2 ©Vecow ECX-3000 PEG User Manual GENERAL INTRODUCTION...
  • Page 19: Specifications Of Ecx-3200 Peg

    2 SATA III (6Gbps) support S/W RAID 0, 1 1 M.2 Key M Socket (2280, PCIe x4) Storage Device 2 Front-access 2.5" SSD/HDD Tray Audio ® Audio Codec Realtek ALC888S-VD, 7.1 Channel HD Audio Audio Interface 1 Mic-in, 1 Line-out ©Vecow ECX-3000 PEG User Manual GENERAL INTRODUCTION...
  • Page 20 Operating Temperature -20°C to 45°C (-4°F to 113°F), with System Fan Storage Temperature -40°C to 85°C (-40°F to 185°F) Humidity 5% to 95% humidity, non-condensing Relative Humidity 95% at 45°C Shock /Vibration Operating, MIL-STD-810G, Procedure I CE, FCC, EN50155, EN50121-3-2 ©Vecow ECX-3000 PEG User Manual GENERAL INTRODUCTION...
  • Page 21: Specifications Of Ecx-3100 Peg

    2 SATA III (6Gbps) support S/W RAID 0, 1 1 M.2 Key M Socket (2280, PCIe x4) Storage Device 2 Front-access 2.5" SSD/HDD Tray Audio ® Audio Codec Realtek ALC888S-VD, 7.1 Channel HD Audio Audio Interface 1 Mic-in, 1 Line-out ©Vecow ECX-3000 PEG User Manual GENERAL INTRODUCTION...
  • Page 22 Operating Temperature -20°C to 45°C (-4°F to 113°F), with System Fan Storage Temperature -40°C to 85°C (-40°F to 185°F) Humidity 5% to 95% humidity, non-condensing Relative Humidity 95% at 45°C Shock /Vibration Operating, MIL-STD-810G, Procedure I CE, FCC, EN50155, EN50121-3-2 ©Vecow ECX-3000 PEG User Manual GENERAL INTRODUCTION...
  • Page 23: Supported Cpu List

    1.4 Supported CPU List Series Cores TDP (W) i9-13900E i9-13900TE i7-13700E i7-13700TE i5-13500E i5-13500TE i3-13100E i3-13100TE ® Intel Core™ i9-12900E i9-12900TE i7-12700E i7-12700TE i5-12500E i5-12500TE i3-12100E i3-12100TE ©Vecow ECX-3000 PEG User Manual GENERAL INTRODUCTION...
  • Page 24: Mechanical Dimension

    1.5 Mechanical Dimension 1.5.1 Dimensions of ECX-3800 PEG Unit : mm (inch) 141.4 (5.57”) 260 (10.24”) 1.5.2 Dimensions of ECX-3600 PEG Unit : mm (inch) 120 (4.72”) 260 (10.24”) ©Vecow ECX-3000 PEG User Manual GENERAL INTRODUCTION...
  • Page 25: Dimensions Of Ecx-3400 Peg

    1.5.3 Dimensions of ECX-3400 PEG Unit : mm (inch) 104 (4.09”) 260 (10.24”) 1.5.4 Dimensions of ECX-3200MX PEG Unit : mm (inch) 104 (4.09”) 260 (10.24”) ©Vecow ECX-3000 PEG User Manual GENERAL INTRODUCTION...
  • Page 26: Dimensions Of Ecx-3200 Peg

    1.5.5 Dimensions of ECX-3200 PEG Unit : mm (inch) 79 (3.11”) 260 (10.24”) 1.5.6 Dimensions of ECX-3100 PEG Unit : mm (inch) 79 (3.11”) 260 (10.24”) ©Vecow ECX-3000 PEG User Manual GENERAL INTRODUCTION...
  • Page 27: Chapter 2 Getting To Know Your Ecx-3000 Peg

    2.1 Packing List 2.1.1 ECX-3800 PEG Packing List Item Description ECX-3800 PEG AI Computing System (According to the configuration of you order, the ECX-3000 PEG series may contain SSD/HDD and DDR5 SO-DIMM. Please verify these items if necessary.) Item Description...
  • Page 28: Ecx-3600 Peg Packing List

    2.1.2 ECX-3600 PEG Packing List Item Description ECX-3600 PEG AI Computing System (According to the configuration of you order, the ECX-3000 PEG series may contain SSD/HDD and DDR5 SO-DIMM. Please verify these items if necessary.) Item Description Outlook Usage P head_...
  • Page 29: Ecx-3400 Peg Packing List

    2.1.3 ECX-3400 PEG Packing List Item Description ECX-3400 PEG AI Computing System (According to the configuration of you order, the ECX-3000 PEG series may contain SSD/HDD and DDR5 SO-DIMM. Please verify these items if necessary.) Item Description Outlook Usage P head_...
  • Page 30: Ecx-3200Mx Peg Packing List

    Black_Nylok Terminal block DC-IN 51-2611R03-S1N 3-pin (7.62mm) Terminal block Switch 51-2211R03-S1A 3-pin (3.5mm) Terminal Isolated DIO/ block 20-pin 51-2112R20-S1D GPIO (2.54mm) Bracket_Wall Wall Mount 62-03P1100-20B Mount SSD/HDD tray ©Vecow ECX-3000 PEG User Manual GETTING TO KNOW YOUR ECX-3000 PEG...
  • Page 31: Ecx-3200 Peg Packing List

    2.1.5 ECX-3200 PEG Packing List Item Description ECX-3200 PEG AI Computing System (According to the configuration of you order, the ECX-3000 PEG series may contain SSD/HDD and DDR5 SO-DIMM. Please verify these items if necessary.) Item Description Outlook Usage P head_...
  • Page 32: Ecx-3100 Peg Packing List

    2.1.6 ECX-3100 PEG Packing List Item Description ECX-3100 PEG AI Computing System (According to the configuration of you order, the ECX-3000 PEG series may contain SSD/HDD and DDR5 SO-DIMM. Please verify these items if necessary.) Item Description Outlook Usage P head_...
  • Page 33: Front Panel I/O Functions

    2.2 Front Panel I/O Functions In Vecow ECX-3000 PEG series family, all I/O connectors are located on front panel and rear panel. Most of the general connections to computer device, such as USB, LAN Jack, USB TYPE-C, HDMI, DVI-I, Display Port and any additional storage, are placed on the front panel.
  • Page 34 Please do note that a 4-second interval between each 2 power-on/power-off operation is necessary in normal working status. (For example, once turning off the system, you have to wait for 4 seconds to initiate another power-on operation). ©Vecow ECX-3000 PEG User Manual GETTING TO KNOW YOUR ECX-3000 PEG...
  • Page 35 • The VGA output mode supports up to 1920x1200 resolution. • If use VGA function will need a DVII to VGA module connecting to DVI-I device. • Below is the DVII to VGA module picture ©Vecow ECX-3000 PEG User Manual GETTING TO KNOW YOUR ECX-3000 PEG...
  • Page 36 There are 4 USB 3.2 connections available supporting up to 10Gb per second data rate in the front side of ECX-3000 PEG series. It also compliant with the requirements of Super Speed (SS), high speed (HS), full speed (FS) and low speed (LS).
  • Page 37 Mini PCIe MPCIe 1 SIM 1 WLAN SIM 3 SIM 2 SIM 1 M.2 KEY B SIM 2 M.2 KEY B SIM 3 M.2 KEY E MPCIE1 M2E_CN1 M2B_CN1 M2B_CN2 ©Vecow ECX-3000 PEG User Manual GETTING TO KNOW YOUR ECX-3000 PEG...
  • Page 38 M2B_SIM1 MPCIE_SIM1 M2B_SIM2 Note : The SIM card sockets do not support hot-plug. Please make sure to unplug the system power before inserting the SIM card(s). ©Vecow ECX-3000 PEG User Manual GETTING TO KNOW YOUR ECX-3000 PEG...
  • Page 39 1000Mbps Ethernet network; The left LED will keep twinkling/off when Ethernet data packets are being transmitted/received. ©Vecow ECX-3000 PEG User Manual GETTING TO KNOW YOUR ECX-3000 PEG...
  • Page 40 There are 4 front-access 2.5" SSD/HDD trays in the front side of ECX- 3800/3600/3400 PEG series and 2 front-access 2.5" SSD/HDD trays in the front side of ECX-3200/3200MX/3100 PEG. Just trigger to open the SSD/HDD tray, up to 4TB is available ©Vecow ECX-3000 PEG User Manual GETTING TO KNOW YOUR ECX-3000 PEG...
  • Page 41 SIM 3 SIM 2 SIM 1 HDMI TypeC DVI-I LAN 2 USB Type-C connector support up to 20Gb per second data rate in the front side of ECX-3000 PEG series. ©Vecow ECX-3000 PEG User Manual GETTING TO KNOW YOUR ECX-3000 PEG...
  • Page 42: Rear Panel I/O & Functions

    This system supports 12V to 50V DC power input by terminal block in the rear side. In normal power operation, power LED lightens in solid green. Supports up to 80V surge protection. Pin No. Definition Pin No. Definition Chassis Ground ©Vecow ECX-3000 PEG User Manual GETTING TO KNOW YOUR ECX-3000 PEG...
  • Page 43 • 3-KVRMS Isolation for 1 minute per UL 1577 • CSA Component Acceptance Notice 5A, IEC 60950-1 and IEC 61010-1 End Equipment Standards • GB4943.1-2011 CQC Certified PIN 1 ~ 8 PIN 11 ~ 18 ©Vecow ECX-3000 PEG User Manual GETTING TO KNOW YOUR ECX-3000 PEG...
  • Page 44 SIO_GPO70 OUTPUT 1 SIO_GPO71 OUTPUT 2 SIO_GPO72 OUTPUT 3 SIO_GPO73 OUTPUT 4 SIO_GPO74 OUTPUT 5 SIO_GPO75 OUTPUT 6 SIO_GPO76 OUTPUT 7 SIO_GPO77 DIO_GND External 6-40VDC (NPN) External 6-48VDC (PNP) ©Vecow ECX-3000 PEG User Manual GETTING TO KNOW YOUR ECX-3000 PEG...
  • Page 45 SIO_GPO22 OUTPUT 1 SIO_GPO26 OUTPUT 2 SIO_GPO64 OUTPUT 3 SIO_GPO65 OUTPUT 4 SIO_GPO41 OUTPUT 5 SIO_GPA5 OUTPUT 6 SIO_GPA4 OUTPUT 7 SIO_GPO27 DIO2_GND External 6-40VDC (NPN) External 6-48VDC (PNP) ©Vecow ECX-3000 PEG User Manual GETTING TO KNOW YOUR ECX-3000 PEG...
  • Page 46 DO Signal circuit in SINK mode (NPN) Source (PNP) DIO_VDC (20) LOAD 7.2K ISOLATION 6-40V (11) (300mA) 1.5K GNDI GNDO GNDO (10.19) Internal Circuit External Device GNDO DO Signal circuit in source mode (PNp) ©Vecow ECX-3000 PEG User Manual GETTING TO KNOW YOUR ECX-3000 PEG...
  • Page 47 SIO GPIO pin is logic low level. GPIO Connectors pin assignments Pin No. Definition Pin No. Definition SIO_GPA3 SIO_GPO22 SIO_GPI56 SIO_GPO26 SIO_GPI57 SIO_GPO64 SIO_GPI15 SIO_GPO65 SIO_GPI16 SIO_GPO41 SIO_GPI35 SIO_GPA5 SIO_GPI46 SIO_GPA4 SIO_GPI11 SIO_GPO27 ©Vecow ECX-3000 PEG User Manual GETTING TO KNOW YOUR ECX-3000 PEG...
  • Page 48 COM 4 The pin assignments are listed in the following table : Serial RS-422 RS-485 Pin No. RS-232 Port (5-wire) (3-wire) TXD- DATA- TXD+ DATA+ RXD+ RXD- 1 to 4 ©Vecow ECX-3000 PEG User Manual GETTING TO KNOW YOUR ECX-3000 PEG...
  • Page 49 COM 1 to COM 4 MB connector table : COM Port MB Connector COM Port MB Connector COM 1 JCOM1 COM 2 JCOM2 COM 3 JCOM3 COM 4 JCOM4 Pin No. Signal Name JCOM1 to JCOM4 ©Vecow ECX-3000 PEG User Manual GETTING TO KNOW YOUR ECX-3000 PEG...
  • Page 50 Twinkling Twinkling Twinkling Right Yellow Yellow Yellow Yellow Green/ Solid Solid Left Orange Green Orange POE LED LED Color POE Status LED 1 - 4 Solid Green POE ON ©Vecow ECX-3000 PEG User Manual GETTING TO KNOW YOUR ECX-3000 PEG...
  • Page 51 Ethernet Cat 5/Cat 6 cable. M12 X-Code 10/100 Mbps 1000Mbps Pin No. E_TX+ MDI0_P PoE+ E_TX- MDI0_N PoE+ E_RX+ MDI1_P PoE- E_RX- MDI1_N PoE- MDI2_P MDI2_N MDI3_P MDI3_N ©Vecow ECX-3000 PEG User Manual GETTING TO KNOW YOUR ECX-3000 PEG...
  • Page 52: Main Board Expansion Connectors

    2.4 Main Board Expansion Connectors 2.4.1 Top View (Component Side) of ECX-3000 PEG Main Board With Connector Location JCMOS1 SUMMIT_FAN 1 SUMITA 1 JUSBPWR1 MPCIE1 SUMITA 2 M2E_CN1 HWIGN_SW1 M2B_CN1 M2B_CN2 SATA4 HDD_PWR4 SATA3 HDD_PWR3 SATA2 HDD_PWR2 SATA1 HDD_PWR1 JP1 JP2...
  • Page 53 SYS_FAN1 COM12_SW1 COM34_SW2 ©Vecow ECX-3000 PEG User Manual GETTING TO KNOW YOUR ECX-3000 PEG...
  • Page 54 2.4.2 Bottom View (Solder Side) of ECX-3000-PEG Main Board With Connector Location CPU_FAN1 SODIMM_1 SODIMM_2 CPU_FAN2 ©Vecow ECX-3000 PEG User Manual GETTING TO KNOW YOUR ECX-3000 PEG...
  • Page 55 The pin-outs of Miscellaneous port are listed in following table: Group Pin No. Description HDD_LED_P HDD LED HDD_LED_N FP_RST_BTN_N RESET BUTTON Ground PWR_LED_P POWER LED PWR_LED_N FP_PWR_BTN_IN POWER BUTTON Ground ©Vecow ECX-3000 PEG User Manual GETTING TO KNOW YOUR ECX-3000 PEG...
  • Page 56 2.4.4 SATA1 to SATA4: SATA III Connector There are 4 onboard high performance Serial ATA III (SATA III) on ECX-3000 PEG. It supports higher storage capacity with less cabling effort and smaller required space. The pin assignments of SATA1 to SATA4 are listed in the following table :...
  • Page 57 DDR5 Channel A SODIMM_2 DDR5 Channel B 2.4.7 CN22 : BIOS_CN1 : BIOS Socket If the BIOS needs to be changed, please contact the Vecow RMA service team. BIOS_CN1 ©Vecow ECX-3000 PEG User Manual GETTING TO KNOW YOUR ECX-3000 PEG...
  • Page 58 The pin assignments of MPCIe 1, MPCIe2 in the following table : Pin No. Signal Name Pin No. Signal Name Reserved +3.3Vaux Reserved Reserved +1.5V Reserved Reserved Reserved +3.3Vaux Reserved +3.3Vaux USB_D+ USB_D- PETp0 PETn0 SMB_DATA ©Vecow ECX-3000 PEG User Manual GETTING TO KNOW YOUR ECX-3000 PEG...
  • Page 59 Signal Name Pin No. Signal Name SMB_CLK +1.5V PERp0 PERn0 +3.3Vaux PERST# Reserved reserved Reserved Mechanical Key UIM_VPP REFCLK+ UIM_RESET REFCLK- UIM_CLK UIM_DATA CLKREQ# UIM_PWR Reserved 1.5V Reserved WAKE# 3.3Vaux ©Vecow ECX-3000 PEG User Manual GETTING TO KNOW YOUR ECX-3000 PEG...
  • Page 60 Fan power connector supports for additional thermal requirements. The pin assignments of CPU_FAN1 and CPU_FAN2 are listed in the following table. CPU_FAN2 CPU_FAN1 Pin No. Function +12V (2A max) Fan speed sensor Fan PWM ©Vecow ECX-3000 PEG User Manual GETTING TO KNOW YOUR ECX-3000 PEG...
  • Page 61 SYS_FAN1 is listed in the following table. SYS_FAN 1 Pin No. Function +12V (2A max) Fan Speed Sencer Fan PWM 2.4.12 SUMIT_FAN1 : SUMIT Fan Header SUMIT_FAN 1 Pin No. Function +12V(2A max) ©Vecow ECX-3000 PEG User Manual GETTING TO KNOW YOUR ECX-3000 PEG...
  • Page 62 Module card types include 3042,3052. M2B_CN1, M2B_CN2 : M.2 KEY B Pin No. Signal Name Pin No. Signal Name Ground Ground 3.3V Ground 3.3V CONFIG_1 3.3V SIM DETECT Ground REFCLKp REFCLKn PEWAKE# ©Vecow ECX-3000 PEG User Manual GETTING TO KNOW YOUR ECX-3000 PEG...
  • Page 63 PERST# PETn0/SATA-A- Ground PERp0/SATA-B- PERn0/SATA-B+ Ground PETp1/USB3.1-Tx+ DEVSLP PETn1/USB3.1-Tx- UIM-PWR Ground UIM-DATA PERp1/USB3.1-Rx+ UIM-CLK PERn1/USB3.1-Rx- UIM-RESET Ground Mechanical Key Ground USB- LED_1# USB+ W_DISABLE1 FULL_CARD_PWR_OFF/ Ground Ground 3.3V 3.3V ©Vecow ECX-3000 PEG User Manual GETTING TO KNOW YOUR ECX-3000 PEG...
  • Page 64 Ground 3.3V Ground 3.3V PEDET 3.3V Ground Mechanical Key Ground REFCLKp REFCLKn PEWAKE# Ground CLKREQ# PETp0/SATA_A+ PERST# PETn0/SATA_A- Ground PERp0/SATA_B- PERn0/SATA_B+ Ground PETp1 DEVSLP PETn1 Ground PERp1 PERn1 Ground ©Vecow ECX-3000 PEG User Manual GETTING TO KNOW YOUR ECX-3000 PEG...
  • Page 65 Wi-Fi,Bluetooth, NFC of GNSS. Module card types include 2230. M2E_CN 1 M2E_CN1 : M.2 KEY E (Dimension : 2230) Pin No. Signal Name Pin No. Signal Name Ground 3.3V 3.3V Ground PEWAKE1# ©Vecow ECX-3000 PEG User Manual GETTING TO KNOW YOUR ECX-3000 PEG...
  • Page 66 I2C_CLK Ground I2C_DATA PEWAKE0# CLKREQ0# Ground PERST0# REFCLKn0 REFCLKp0 Ground PERn0 PERp0 Ground PETn0 DEVSLP PETp0 Ground Mechanical Key Ground Ground Ground Ground USB- LED1# USB+ 3.3V Ground 3.3V ©Vecow ECX-3000 PEG User Manual GETTING TO KNOW YOUR ECX-3000 PEG...
  • Page 67 2.4.16 JCOM1,JCOM2,JCOM3,JCOM4 : Serial Port cable Connector JCOM4 JCOM2 JCOM3 JCOM1 Location Description JCOM1 COM1 JCOM2 COM2 JCOM3 COM3 JCOM4 COM4 ©Vecow ECX-3000 PEG User Manual GETTING TO KNOW YOUR ECX-3000 PEG...
  • Page 68 Pin No. Function 2.4.17 JIGN_FW1 : IGNITION FW Programming Header JIGN_FW1 Pin No. Description MCU_RST# +V3.3_MCU MCU_PRG ©Vecow ECX-3000 PEG User Manual GETTING TO KNOW YOUR ECX-3000 PEG...
  • Page 69 2.4.18 Graphic Card Power Connector Pin No. Definition +12V +12V +12V ©Vecow ECX-3000 PEG User Manual GETTING TO KNOW YOUR ECX-3000 PEG...
  • Page 70: Main Board Jumper Settings

    To “open” a jumper, you remove the clip. Sometimes a jumper will have three pins, labeled 1, 2 and 3. In this case you would connect either pins 1 and 2, or 2 and 3. Open Closed Closed 2-3 ©Vecow ECX-3000 PEG User Manual GETTING TO KNOW YOUR ECX-3000 PEG...
  • Page 71 WLAN LAN 1 SIM 3 SIM 2 SIM 1 HDMI TypeC DVI-I LAN 2 Rear Plane View DC-IN On / Off COM 1 COM 3 COM 2 COM 4 ©Vecow ECX-3000 PEG User Manual GETTING TO KNOW YOUR ECX-3000 PEG...
  • Page 72 COM2 2 - 3 RI(Default) 1 - 2 +12V (0.5A max.) JRI_PWR3 COM3 2 - 3 RI(Default) 1 - 2 +12V (0.5A max.) JRI_PWR4 COM4 2 - 3 RI(Default) ©Vecow ECX-3000 PEG User Manual GETTING TO KNOW YOUR ECX-3000 PEG...
  • Page 73 No Jumper Disable PoE power 2.5.5 JCMOS1 : Clear CMOS JCMOS1 Location Description Function 1 - 2 *Normal (Default) JCMOS1 2 - 3 Clear CMOS ©Vecow ECX-3000 PEG User Manual GETTING TO KNOW YOUR ECX-3000 PEG...
  • Page 74 JP1, JP2 logic setting are listed in the following table. Logic Logic JP1, JP2 PCI Express configurations are listed in the following table. PCI Express* Bifurcation 1 x8 PCI Express* 2 x8 PCI Express* 1 x16 PCI Express* ©Vecow ECX-3000 PEG User Manual GETTING TO KNOW YOUR ECX-3000 PEG...
  • Page 75 2.5.7 JIGNMODE1 : IGNITION Mode JIGNMODE1 Location Description Function 1 - 2 H/W mode JIGNMODE1 2 - 3 S/W mode(default) ©Vecow ECX-3000 PEG User Manual GETTING TO KNOW YOUR ECX-3000 PEG...
  • Page 76 DCD / RXD Termination 120R enable COM1 DCD / RXD Termination 120R 1(OFF) Disable(default) COM34_120R_SW1 2(ON) DCD / RXD Termination 120R enable COM2 DCD / RXD Termination 120R 2(OFF) Disable(default) ©Vecow ECX-3000 PEG User Manual GETTING TO KNOW YOUR ECX-3000 PEG...
  • Page 77: Ignition Control

    The built-in MCU monitors the ignition signal and turns on/off the system according to pre-defined on/off delay period. 2.6.1 Adjust Ignition Control Modes ECX-3000 PEG provides 16 modes of different power on/off delay periods adjustable via SW2 switch. The default rotary switch is set to 0 in ATX/AT power mode.
  • Page 78 60 seconds 5 seconds 90 seconds 5 seconds 120 seconds 10 seconds 10 seconds 10 seconds 30 seconds 10 seconds 60 seconds 10 seconds 90 seconds 10 seconds 120 seconds ©Vecow ECX-3000 PEG User Manual GETTING TO KNOW YOUR ECX-3000 PEG...
  • Page 79 Note : 1. DC power source and IGN share the same ground. 2. ECX-3000 PEG supports 12V to 50V wide range DC power input in ATX/AT mode. In Ignition mode, the input voltage is fixed to 12V/24V for car battery scenario.
  • Page 80: Chapter 3 System Setup

    SYSTEM SETUP 3.1 Installing CPU Step 1 Remove four flat head M3x5L screws, four pan head SFW M3x6L screws pan head SFW M2.5x6L screw, and take out heat sink. ©Vecow ECX-3000 PEG User Manual SYSTEM SETUP...
  • Page 81 Step 2 Take out heat sink. ©Vecow ECX-3000 PEG User Manual SYSTEM SETUP...
  • Page 82 Step 3 Remove CPU mylar Step 4 Open CPU independent loading mechanism (ILM) ©Vecow ECX-3000 PEG User Manual SYSTEM SETUP...
  • Page 83 Step 5 Install CPU. (Be careful CPU pin) Step 6 Close CPU independent loading Mechanism (ILM) and finish ©Vecow ECX-3000 PEG User Manual SYSTEM SETUP...
  • Page 84: Installing Ddr5 So-Dimm Modules

    3.2 Installing DDR5 SO-DIMM Modules Step 1 Remove four flat head M3x5L screws, four pan head SFW M3x6L screws pan head SFW M2.5x6L screw, and take out heat sink. ©Vecow ECX-3000 PEG User Manual SYSTEM SETUP...
  • Page 85 Step 2 Take out heat sink. Step 3 Install DDR5 RAM module into SO-DIMM socket ©Vecow ECX-3000 PEG User Manual SYSTEM SETUP...
  • Page 86 Step 4 Make sure RAM module is locked by the memory slot ©Vecow ECX-3000 PEG User Manual SYSTEM SETUP...
  • Page 87: Installing Mini Pcie Card

    3.3 Installing Mini PCIe Card Step 1 Remove four flat head M3x5L screws. ©Vecow ECX-3000 PEG User Manual SYSTEM SETUP...
  • Page 88 Step 2 Open bottom cover. ©Vecow ECX-3000 PEG User Manual SYSTEM SETUP...
  • Page 89 Step 3 Install mini PCIe card into slot Step 4 Fasten pan head SFW M2.5x6L screw ©Vecow ECX-3000 PEG User Manual SYSTEM SETUP...
  • Page 90: Installing Nano Sim Card

    3.4 Installing Nano SIM Card Step 1 Release captive panel screw. Step 2 Open service Card. ©Vecow ECX-3000 PEG User Manual SYSTEM SETUP...
  • Page 91: Installing Removable Rtc Battery

    Step 3 Insert nano SIM card and push to lock. 3.5 Installing Removable RTC Battery Step 1 Release captive panel screw. Step 2 Open service Card. ©Vecow ECX-3000 PEG User Manual SYSTEM SETUP...
  • Page 92: Installing Pci/Pci Card

    3.6 Installing PCI/PCI Card System designs will support 126 mm maximum height, 219 mm maximum length (Without the I/O bracket & auxiliary power card) PCI/PCI Express add-in cards. Step 1 Remove eight flat head M3x5L screws. ©Vecow ECX-3000 PEG User Manual SYSTEM SETUP...
  • Page 93 Step 2 Open bottom cover & add-in card cover. ©Vecow ECX-3000 PEG User Manual SYSTEM SETUP...
  • Page 94 Step 3 Separate Assembly_Riser Card from the enclosure with the puller. Step 4 Turn riser card assembly upside-down on a steady surface. ©Vecow ECX-3000 PEG User Manual SYSTEM SETUP...
  • Page 95 Step 5 Remove the screw indicated, and separate I/O bracket from riser card assembly. Step 6 Instal PCI/PCIe add-in card, and fasten the screw indicated. ©Vecow ECX-3000 PEG User Manual SYSTEM SETUP...
  • Page 96: Installing Ssd/Hdd

    Step 1 Use the trigger and open Step 2 Open front door of SSD/HDD SSD/HDD tray. tray. Step 3 Install 2.5" SSD/HDD into the Step 4 Lock the SSD/HDD tray with tray and close. key. ©Vecow ECX-3000 PEG User Manual SYSTEM SETUP...
  • Page 97: Installing

    3.8 Installing M.2 3.8.1 M.2 Key M 2280 Step 1 Remove four flat head M3x5L screws, four pan head SFW M3x6L screws pan head SFW M2.5x6L screw, and take out heat sink. ©Vecow ECX-3000 PEG User Manual SYSTEM SETUP...
  • Page 98 Step 2 Take out heat sink, and install M.2 module card into slot and fasten I head M3x4L screw. 3.8.2 M.2 Key B 3042/3052/2280 & Key E 2230 Step 1 Remove four flat head M3x5L screws. ©Vecow ECX-3000 PEG User Manual SYSTEM SETUP...
  • Page 99 Step 2 Open bottom cover. ©Vecow ECX-3000 PEG User Manual SYSTEM SETUP...
  • Page 100 M.2 Key B 3042 module card and fasten I head M3x4L screw. M.2 Key E 2230 : Install M.2 Key E 2230 module card into slot, and fasten I head M3x4L screw ©Vecow ECX-3000 PEG User Manual SYSTEM SETUP...
  • Page 101: Installing Antenna Cable

    3.9 Installing Antenna Cable Step 1 Remove eight flat head M3x5L screws. ©Vecow ECX-3000 PEG User Manual SYSTEM SETUP...
  • Page 102 Step 2 Open bottom cover & add-in card cover. Step 3 Separate Assembly_Riser Card from the enclosure with the puller. ©Vecow ECX-3000 PEG User Manual SYSTEM SETUP...
  • Page 103 Step 4 Remove hole plug. Step 5 Install SMA cable, and fasten washer and nut. ©Vecow ECX-3000 PEG User Manual SYSTEM SETUP...
  • Page 104: Mounting Your Ecx-3000-Peg

    3.10 Mounting Your ECX-3000-PEG 3.10.1 Wall Mount ( Type I ) Fasten four flat head M3x5L screws. ©Vecow ECX-3000 PEG User Manual SYSTEM SETUP...
  • Page 105 3.10.2 Wall Mount ( Type I I) Fasten four flat head M3x5L screws. ©Vecow ECX-3000 PEG User Manual SYSTEM SETUP...
  • Page 106 3.10.3 Wall Mount ( Type III ) Fasten six flat head M3x5L screws. 3.10.4 VESA Mount ( Optional ) Fasten six flat head M3x5L screws. ©Vecow ECX-3000 PEG User Manual SYSTEM SETUP...
  • Page 107 Install DIN Rail assembly with six flat head M3x5L screws. 3.10.6 2U Rack Mount ( Optional ) The 2U Rackmount is only for ECX-3200/3200MX/3100 PEG Series. For more information, please contact Vecow support team. ©Vecow ECX-3000 PEG User Manual SYSTEM SETUP...
  • Page 108: Chapter 4 Bios Setup

    Figure 4-1 : Entering Setup Screen BIOS provides an interface for users to check and change system configuration. The BIOS setup program is accessed by pressing the <Del> key when POST display output is shown. ©Vecow ECX-3000 PEG User Manual BIOS SETUP...
  • Page 109: Main Menu

    Set the Date. Use <Tab> to switch between Date elements. Default Ranges: Year: 1998-9999 Months: 1-12 Days: Dependent on month Range of Years may vary. System Time Set the Time. Use <Tab> to switch between Time elements. ©Vecow ECX-3000 PEG User Manual BIOS SETUP...
  • Page 110: Advanced Menu

    Efficient-core Information Displays the E-core Information. Performance-core Information Displays the P-core Information. Hardware Prefetcher To turn on/off the MLC streamer prefetcher. Adjacent Cache Line Prefetch To turn on/off prefetching of adjacent cache lines. ©Vecow ECX-3000 PEG User Manual BIOS SETUP...
  • Page 111 Cores and E-cores are looked at together. When both are {0,0}, Pcode will enable all cores. Hyper-Threading Enable or Disable Hyper-Threading Technology. Enable/Disable AES (Advanced Encryption Standard). 4.3.2 PCH-HW Configuration Figure 4-3-2 : PCH-HW Configuration PTT Configuration Configure PTT. ©Vecow ECX-3000 PEG User Manual BIOS SETUP...
  • Page 112 Enables or Disables System ability to Hibernate (OS/S4 Sleep State). This option may not be effective with some operating systems. ACPI Sleep State Selects the highest ACPI sleep state the system will enter when the SUSPEND button is pressed. ©Vecow ECX-3000 PEG User Manual BIOS SETUP...
  • Page 113 Enable or Disable PPS. High Speed Mode Enable or disable High Speed Serial Port. Note: A device driver is required on OS for high speed serial port function. (High Speed Serial Port is Port 1 only) ©Vecow ECX-3000 PEG User Manual BIOS SETUP...
  • Page 114 Fan full speed temperature limit Fan will full speed when temperature higher than this limit. Fan start PWM Fan will start with this PWM value. Manual PWM Setting Fan will work with this Manual PWM Value. ©Vecow ECX-3000 PEG User Manual BIOS SETUP...
  • Page 115 Number of times the presence of media will be checked. Use either +/- or numeric keys to set the value. 4.3.8 NVMe Configuration Figure 4-3-8 : NVMe Configuration Display NVMe controller and Drive information. ©Vecow ECX-3000 PEG User Manual BIOS SETUP...
  • Page 116: Chipset Menu

    4.4.1 System Agent (SA) Configuration Figure 4-4-1 : System Agent (SA) Configuration VT-d VT-d capability. Above 4GB MMIO BIOS assignment Enable/disable above 4GB MemoryMappedIO BIOS assignment. This is enabled automatically when Aperture Size is set to 2048MB. ©Vecow ECX-3000 PEG User Manual BIOS SETUP...
  • Page 117 GTT Size Select the GTT Size. Aperture Size Select the Aperture Size. Note : Above 4GB MMIO BIOS assignment is automatically enabled when selecting 2048MB aperture. To use this feature, please disable CSM Support. ©Vecow ECX-3000 PEG User Manual BIOS SETUP...
  • Page 118 Specify what state to go to when power is re-applied after a power failure (G3 state). S0 State : Always turn-on the system when power source plugged-in. S5 State : Always turn-off the system when power source plugged-in. ©Vecow ECX-3000 PEG User Manual BIOS SETUP...
  • Page 119 Figure 4-4-3 : Module Management DVI/VGA DDC channel selection Configure DVI/VGA DCC channel selection. M2B CN1 PCI-E/USB channel Select M2B CN1 PCI-E/USB channel selection. M2B CN2 PCI-E/USB channel Select M2B CN2 PCI-E/USB channel selection. ©Vecow ECX-3000 PEG User Manual BIOS SETUP...
  • Page 120 Voltage Guard enable or disable, only effect on ignition mode. Voltage Guard lower limit value Voltage Guard lower limit value setting Range : 9V~40V Voltage Guard Higher limit value Voltage Guard Higher limit value setting Range : 15V~55V ©Vecow ECX-3000 PEG User Manual BIOS SETUP...
  • Page 121: Security Menu

    4.5 Security Menu Figure 4-5 : BIOS Security Menu Administrator Password Set administrator password. ©Vecow ECX-3000 PEG User Manual BIOS SETUP...
  • Page 122 Discard or Save changes option in setup does not have any impact on HDD when password is set or removed. If the 'Set HDD User Password' option is hidden, do power cycle to enable the option again. Set Master Password Set Master Password. ©Vecow ECX-3000 PEG User Manual BIOS SETUP...
  • Page 123 Force System to User Mode. Install factory default Secure Boot key databases. Reset To Setup Mode Delete all Secure Boot key databases from NVRAM. Key Management Enables expert users to modify Secure Boot Policy variables without variable authentication. ©Vecow ECX-3000 PEG User Manual BIOS SETUP...
  • Page 124: Boot Menu

    Figure 4-7 : BIOS Save and Exit Menu Save Changes and Reset Reset the system after saving the changes. Discard Changes and Reset Reset system setup without saving any changes. Restore Defaults Restore/Load Default values for all the setup options. ©Vecow ECX-3000 PEG User Manual BIOS SETUP...
  • Page 125: Appendix A : Isolated Dio/Gpio Guide

    PoE+ PoE+ PoE+ PoE+ PoE+ PoE+ Do NOT use these functions in below : 1. PE-2000 : DIO1 (ID = 0), POE 2. PE-3000 : POE 3. UE-1000 : USB (ID = 0) ©Vecow ECX-3000 PEG User Manual Appendix A...
  • Page 126 DIO Connector (NPN, Default) 6-48V DC DIO_VDC (Pin 20) DO (Pin 11-18) DIO_GND (Pin 10, 19) Source Mode Device DIO Connector (PNP) 6-48V DC DIO_VDC (Pin 20) DO (Pin 11-18) DIO_GND (Pin 10, 19) ©Vecow ECX-3000 PEG User Manual Appendix A...
  • Page 127 Header folder include head file for software developer or System Integration. Manual folder include API description. Sample folder include sample program, driver library, and API library for Windows/Linux Source folder include sample program source code that compile on Visual Studio 2008/ubuntu16.04. ©Vecow ECX-3000 PEG User Manual Appendix A...
  • Page 128 A.4 Sample Execute demo tool. Windows Linux A.4.1 DIO Sample A.4.1.1 Auto load SIO configuration(.\IOConfig\ machine series) and initial SIO then choosing IO port you want to control. A.4.1.2 Select IO port mode(see Config). ©Vecow ECX-3000 PEG User Manual Appendix A...
  • Page 129 A.4.1.2.1 Isolated DIO access then choose DI or DO access. Figure. Isolated DIO access. Step 1 DI access and set DI mode(sink or source). Figure. Get DI sink/source mode data ©Vecow ECX-3000 PEG User Manual Appendix A...
  • Page 130 Figure. DI sink mode data. Figure. DI source mode data. ©Vecow ECX-3000 PEG User Manual Appendix A...
  • Page 131 Step 2 DO access and set DO mode (sink or source). Figure. Get DI sink/source mode data Step 2.1 Choose DO port. ©Vecow ECX-3000 PEG User Manual Appendix A...
  • Page 132 Step 2.2 Set DO high or low then show message. A.4.1.2.2 GPIO access and set GPIO configuration. ©Vecow ECX-3000 PEG User Manual Appendix A...
  • Page 133 Step 1 Example : Set GPIO configuration 0xFF00 and get GPIO data(loopback test). Step 2 Set GPIO data 0x4321 and get GPIO data(loopback test). ©Vecow ECX-3000 PEG User Manual Appendix A...
  • Page 134 To use the Vecow_DIO_loopback function, a test fixture is required. For the detailed connection method of the test fixture, please refer to the relevant documents of vecow. Step 1 Please select Vecow_DIO_loopback Step 2 Please select the mode to test ©Vecow ECX-3000 PEG User Manual Appendix A...
  • Page 135 Step 3 A normal test will continue to send data from DO, and DI will receive the same data and execute it repeatedly (the test will not stop). ©Vecow ECX-3000 PEG User Manual Appendix A...
  • Page 136 Step 4 When the test is wrong, it will stop the test after 6 consecutive tests and display an error message. ©Vecow ECX-3000 PEG User Manual Appendix A...
  • Page 137 Step 1 Initial POE and auto detected useful slave address ID. Step 2 Choose useful slave address ID and show its address, then choose POE port that you want to control. Step 3 Set Manual or Auto mode. ©Vecow ECX-3000 PEG User Manual Appendix A...
  • Page 138 Step 3.1 Set Auto mode and show success message. Step 3.2 Set Manual mode and then turn OF/OFF POE port. Step 3.3 Set POE port success message. ©Vecow ECX-3000 PEG User Manual Appendix A...
  • Page 139 A.4.4 WDT A.4.4.1 WDT once Step 1 Auto load SIO configuration and initial SIO then set WDT seconds. Step 2 Set WDT success message. Step 3 Time out message. ©Vecow ECX-3000 PEG User Manual Appendix A...
  • Page 140 A.4.5 WDT LOOP Step 1 Auto load SIO configuration and initial SIO then set WDT loop seconds. Step 2 80% WDT time will rest WDT again, if close .exe will reboot. ©Vecow ECX-3000 PEG User Manual Appendix A...
  • Page 141: Appendix B : Software Functions

    APPENDIX B : Software Functions B.1 Driver API Guide In Header folder, Vecow.h and VecowLinux.h contain usabled API for Windows/Linux. BOOL initial_SIO(BYTE Isolate_Type, BYTE DIO_NPN) Initial machine for IO and watch dogtimer. Isolate_Type : DIO type. 1 : Isolated DIO;...
  • Page 142 DO ([7:0]) : Output state, pin setting by hexadecimal bitmask. 1 : High; 0 : Low. Return : TRUE (1) : Success. FALSE (0) : Fail (Initial error or hardware problem). FALSE (0) : Fail (Initial error or hardware problem). ©Vecow ECX-3000 PEG User Manual Appendix B...
  • Page 143 FALSE (0) : Fail (Driver not exists, or version is too old, or out of range error). BOOL get_POE_configuration(BYTE ID, BYTE *Auto, BYTE *Mask) Get POE configuration (by variable). ID : POE ID. Range : 0~15. Auto ([3:0]) : Auto mode, pin setting by hexadecimal bitmask. ©Vecow ECX-3000 PEG User Manual Appendix B...
  • Page 144 B. POE ([3:0]) : POE state, pin setting by hexadecimal bitmask. 1 : On; 0 : Off. Return : TRUE (1) : Success. FALSE (0) : Fail (Initial error, or out of range error, or hardware problem). ©Vecow ECX-3000 PEG User Manual Appendix B...
  • Page 145: Appendix C : Raid Functions

    Chipset → System Agent (SA) Configuration → Enable VMD controller → Enabled → Save Changes and Reset. C.1.2 UEFI Mode for RAID 1. Into BIOS menu again, select Intel(R) Rapid Storage Technology on BIOS menu. Advanced → Intel(R) Rapid Storage Technology ©Vecow ECX-3000 PEG User Manual Appendix C...
  • Page 146 2. Select Create RAID Volume on BIOS menu. 3. Select disks to create RAID Volume then Save Changes and Reset to install OS with EFI mode. ©Vecow ECX-3000 PEG User Manual Appendix C...
  • Page 147 The RAID environment has been done if you completed the steps above. C.5 To Insert SATA HDD for RAID 1 Please note, you can use two SATA ports for SATA HDD, except for mSATA slot. ©Vecow ECX-3000 PEG User Manual Appendix C...
  • Page 148 C.6 To Create RAID Volume on"Rapid Storage Technology" Software ECX-3000 PEG is featured with two SATA HDD’s for RAID volume, so there are two options to choose on this page. Let’s take RAID 1 as an example, select ”RAID 1”.
  • Page 149 Then add"Logical Device" for Windows access. C.8 If One SATA HDD on RAID Volume is Out-of-use After RAID 1 volume is created, you can see the figure of SATA device allocation. HDD CAUTION Sign ©Vecow ECX-3000 PEG User Manual Appendix C...
  • Page 150 A warning will pop-up to ask you if the disk is not a member of the original RAID volume. If you press"Rebuild", it will replace the broken SATA HDD to the last SATA HDD of RAID volume. ©Vecow ECX-3000 PEG User Manual Appendix C...
  • Page 151: Appendix D : Power Consumption

    1.0 Gbps LAN3 (i226-IT) 2.5 Gbps LAN4 (i226-IT) 2.5 Gbps LAN5 (i226-IT) 2.5 Gbps LAN6 (i226-IT) 2.5 Gbps Graphics output HDMI Power plan Balance(Windows10 Power plan) Power Source : Chroma 62006P-100-25 Test Program-1 BurnInTest ©Vecow ECX-3000 PEG User Manual Appendix D...
  • Page 152 Core i7- 6.735A 60.62W 9.468A 85.21W 12700TE ® Intel Core i7- 4.963A 59.56W 6.725A 80.70W 12700TE ® Intel Core i7- 2.414A 57.94W 3.467A 83.21W 12700TE ® Intel Core i7- 1.504A 75.18W 1.951A 97.54W 12700TE ©Vecow ECX-3000 PEG User Manual Appendix D...
  • Page 153 Consumption ® Intel Core 11.747A 105.72W 11.019A 99.17W i9-12900E Intel ® Core 7.725A 92.70W 7.947A 95.36W i9-12900E ® Intel Core 3.962A 95.09W 4.949A 118.77W i9-12900E ® Intel Core 2.136A 106.82W 2.271A 113.56W i9-12900E ©Vecow ECX-3000 PEG User Manual Appendix D...
  • Page 154 Consumption ® Intel Core 6.990A 62.91W 9.553A 85.98W i7-13700E Intel ® Core 5.289A 63.47W 7.154A 85.85W i7-13700E ® Intel Core 2.521A 60.50W 3.635A 87.24W i7-13700E ® Intel Core 1.434A 71.72W 1.870A 93.51W i7-13700E ©Vecow ECX-3000 PEG User Manual Appendix D...
  • Page 155 Consumption ® Intel Core 6.173A 74.07W 9.251A 111.01W i7-13700E ® Intel Core 3.085A 74.05W 4.455A 106.91W i7-13700E ® Intel Core 2.105A 75.77W 3.028A 109.00W i7-13700E ® Intel Core 1.691A 84.56W 2.367A 118.37W i7-13700E ©Vecow ECX-3000 PEG User Manual Appendix D...
  • Page 156: Appendix E : Supported Memory & Storage List

    E.1 Test Item Testing Board ECX-3000PEG Memory Test MemTest86 V10.4 BurnInTest V9.2 Channel Memtest Bunin Flash BIOS Remove Battery PASS PASS PASS PASS *1 (Socket 1) PASS PASS PASS *1 (Socket 2) PASS PASS PASS ©Vecow ECX-3000 PEG User Manual Appendix E...
  • Page 157 Test Temp. Brand Info (Celsius) NMES532F81- Goldkey 32G DDR5 4800 SO-DIMM 25ºC 4800JA0C SMART 32G DDR5 4800 SO-DIMM SR4G7SO5285-SB 25ºC SLLINK 32G DDR5 4800 SO-DIMM J5BGDH2G8A4XC 25ºC Innodisk 32G DDR5 4800 SO-DIMM M5D0-BGS2QCVP-H03 25ºC ©Vecow ECX-3000 PEG User Manual Appendix E...
  • Page 158 SA2000MB 250GB 970 EVO PLUS 250GB MZ-V7S250 M.2 PCIe SAMSUNG 980 EVO PRO 250GB MZ-V8P250BW 760P INTEL 128GB SSDPEKKW128G8 SMART FDMP8960GTCXA111 960GB ** If more help is needed, please contact Vecow Technical Support.** ©Vecow ECX-3000 PEG User Manual Appendix E...
  • Page 159 No part of this publication may be reproduced in any form or by any means, electric, photocopying, or recording, without prior authorization from the publisher. The rights of all the brand names, product names, and trademarks belong to their respective owners. © Vecow Co., Ltd. 2023. All rights reserved.