Glan Enable/Disable; Vga Enable/Disable; Front Side Bus Speed; Scsi Enable/Disable - Supermicro 7043P-8R User Manual

Supermicro superserver 7043p-8r servers: user guide
Table of Contents

Advertisement

GLAN Enable/Disable

Change the setting of jumper JD4
to enable or disable the onboard
GLAN ports (GLAN1 and GLAN2)
on the serverboard. See the table
on the right for jumper settings.
The default setting is enabled

VGA Enable/Disable

JP4 allows you to enable or disable
the VGA port. The default position
is on pins 1 and 2 to enable VGA.
See the table on the right for
jumper settings.

Front Side Bus Speed

JP39 is used to set the system
(front side) bus speed for the pro-
cessors.
It is best to keep this
jumper set to Auto. This jumper is
used together with the CPU Clock
setting in BIOS. See the table on
the right for jumper settings.

SCSI Enable/Disable

The SCSI Termination jumper at
JP22 allows you to enable or dis-
able the onboard SCSI controller.
The normal (default) position is on
pins 1-2 to enable SCSI termina-
tion. See the table on the right for
jumper settings.
Chapter 5: Advanced Serverboard Setup
Jum per
Position
Pins 1-2
Pins 2-3
Position
Front Side Bus Speed
Jumper Settings (JP39)
Jumper
Position
Pins 1-2
Pins 2-3
Open
SCSI Enable/Disable
Jumper
Position
Pins 1-2
Pins 2-3
5-19
GLAN
Enable/Disable
Jumper Settings
(JD4)
Definition
Enabled
Disabled
VGA Enable/Disable
Jumper Settings
(JP4)
Jumper
Definition
1-2
Enabled
2-3
Disabled
Definition
Auto
400 MHz
533 Mhz
Jumper Settings
(JP22)
Definition
Enabled
Disabled