3rd Power Supply Alarm
Enable/Disable
The system can notify you in the
event of a power supply failure.
This feature assumes that three
power supply units are installed in
the chassis with one acting as a
backup.
If you only have one or
two power supply units installed,
you should disable this (the default
setting) with JP10 to prevent false
alarms. See the table on right for
pin definitions.
VGA Enable/Disable
JPG1 enables or disables the VGA
Connector on the motherboard.
See the table on the right for
jumper settings.
ting is enabled.
GLAN Enable/Disable
Change the setting of jumper JPL1
to enable or disable the onboard
GLAN ports (GLAN1 and GLAN2)
on the serverboard. See the table
on the right for jumper settings.
The default setting is enabled
Chapter 5: Advanced Serverboard Setup
The default set-
5-21
Power Supply
Alarm Enable/Disable
Jumper Settings (JP10)
Jumper
Position
Definition
Open
Disabled
Closed
Enabled
VGA
Enable/Disable
Jumper Settings
(JPG1)
Jumper
Position
Definition
Pins 1-2
Enabled
Pins 2-3
Disabled
GLAN
Enable/Disable
Jumper Settings
(JPL1)
Jumper
Position
Definition
Pins 1-2
Enabled
Pins 2-3
Disabled