Installing The Superserver 6013A-T Into A Rack; Identifying The Sections Of The Rack Rails - Supermicro SUPERSERVER 6013A-T User Manual

Supermicro superserver 6013a-t servers: user guide
Hide thumbs Also See for SUPERSERVER 6013A-T:
Table of Contents

Advertisement

S
S
UPER
ERVER 6013A-T User's Manual
2-4
Installing the 6013A-T into a Rack
This section provides information on installing the SuperServer 6013A-T into
a rack unit. If the system has already been mounted into a rack, you can
skip ahead to Sections 2-5 and 2-6. There are a variety of rack units on the
market, which may mean the assembly procedure will differ slightly.
following is a guideline for installing the unit into a rack with the rack rails
provided with the system. You should also refer to the installation instruc-
tions that came with the rack unit you are using.

Identifying the Sections of the Rack Rails

You should have received two rack rail assemblies with the SuperServer
6013A-T. Each of these assemblies consist of two sections: an inner fixed
chassis rail that secures to the unit (A) and an outer fixed rack rail that
secures directly to the rack itself (B).
between the two should remain attached to the fixed rack rail (see Figure
2-1). The A and B rails must be detached from each other to install.
To remove the fixed chassis rail (A), pull it out as far as possible - you
should hear a "click" sound as a locking tab emerges from inside the rail
assembly and locks the inner rail. Then depress the locking tab to pull the
inner rail completely out. Do this for both the left and right side rack rail
assemblies.
Mounting Holes
Figure 2-1.
A
Identifying the Sections of the Rack Rails
2-4
A sliding rail guide sandwiched
B
Locking Tab
The