Page 2
Clara County in the State of California, USA. The State of California, County of Santa Clara shall be the exclusive venue for the resolution of any such disputes. Supermicro's total liability for all claims will not exceed the price paid for the hardware product.
SuperServer 6014H-T. Instal- lation and maintainance should be performed by experienced technicians only. The SuperServer 6014H-T is a high-end 1U rackmount server based on the SC813T- 500 1U rackmount server chassis and the X6DHR-TG serverboard, which supports single or dual Intel®...
Page 4
UPER ERVER 6014H-T Manual Chapter 4: System Safety You should thoroughly familiarize yourself with this chapter for a general overview of safety precautions that should be followed when installing and servicing the SuperServer 6014H-T. Chapter 5: Advanced Serverboard Setup Chapter 5 provides detailed information on the X6DHR-TG serverboard, including the locations and functions of connectors, headers and jumpers.
UPER ERVER 6014H-T Manual Table of Contents Preface About This Manual ... iii Manual Organization ... iii Chapter 1: Introduction Overview ... 1-1 Serverboard Features ... 1-2 Server Chassis Features ... 1-4 Contacting Supermicro ... 1-6 Chapter 2: Server Installation Overview ...
Page 7
Power ... 3-3 Serial ATA Drive Carrier LED ... 3-3 Chapter 4: System Safety Electrical Safety Precautions ... 4-1 General Safety Precautions ... 4-2 ESD Precautions ... 4-3 Operating Precautions ... 4-4 Chapter 5: Advanced Serverboard Setup Handling the Serverboard ... 5-1 Processor and Heatsink Installation ...
Page 8
UPER ERVER 6014H-T Manual JLAN 1/2 (Ethernet Ports) ... 5-14 Extra USB Headers ... 5-15 Power LED/Speaker ... 5-15 ATX PS/2 Keyboard & Mouse Ports ... 5-15 Overheat LED ... 5-15 Wake-On-LAN ... 5-16 Wake-On-Ring ... 5-16 SMB ... 5-16 SMB Power ...
Page 9
Chapter 7: BIOS Introduction ... 7-1 Running Setup ... 7-2 Main BIOS Setup ... 7-2 Main BIOS Setup Menu ... 7-3 Advanced Setup ... 7-7 Security ... 7-18 Boot ... 7-20 Exit ... 7-22 Appendices: Appendix A: BIOS POST Messages ... A-1 Appendix B: BIOS POST Codes ...
Overview The Supermicro SuperServer 6014H-T is a high-end dual processor, 1U rackmount server featuring some of the most advanced technology currently available. The SuperServer 6014H-T is comprised of two main subsystems: the SC813T-500 1U rackmount chassis and the X6DHR-TG Xeon dual processor serverboard. Please refer to our web site for information on operating systems that have been certifi...
ERVER 6014H-T Manual Serverboard Features At the heart of the SuperServer 6014H-T lies the X6DHR-TG a dual Xeon pro- cessor serverboard designed to provide maximum performance. Below are the main features of the X6DHR-TG. See Figure 1-1 for a system block diagram of the chipset.
ATI Graphics Controller An ATI video controller based on the Rage XL 8 MB graphics chip is integrated onboard the X6DHR-TG. Rage XL fully supports sideband addressing and AGP texturing. This onboard graphics package can provide a bandwidth of up to 512 MB/sec over a 32-bit graphics memory bus.
The SC813T-500 chassis includes a single 500W cold-swap power supply. Serial ATA Subsystem For the 6014H-T, the SC813T-500 chassis was designed to support four Serial ATA hard drives, which are hot-swappable units. Note: The operating system you use must have RAID support to enable the hot- swap capability of the Serial ATA drives.
Figure 1-1. Intel E7520 Chipset: System Block Diagram Note: This is a general block diagram. Please see Chapter 5 for details. PCI-E_(X8) Gbit LAN ANVIK 1_PCI-X133 SLOT--6 PCI-X BUS(133MHZ) PXH#2 PCI-X BUS(100MHZ) 1_PCI-X100 SLOT--7 PCI-E_(X8) SATA 4 Ports SOCKET PRI/SEC SATA 0, 1 USB PORTS...
Unpacking the System You should inspect the box the SuperServer 6014H-T was shipped in and note if it was damaged in any way. If the server itself shows damage you should fi le a damage claim with the carrier who delivered it.
UPER ERVER 6014H-T Manual Choosing a Setup Location - Leave enough clearance in front of the rack to enable you to open the front door completely (~25 inches). - Leave approximately 30 inches of clearance in the back of the rack to allow for suffi...
Chapter 2: Server Installation Rack Mounting Considerations Ambient Operating Temperature If installed in a closed or multi-unit rack assembly, the ambient operating tem- perature of the rack environment may be greater than the ambient temperature of the room. Therefore, consideration should be given to installing the equip- ment in an environment compatible with the manufacturer’s maximum rated ambient temperature (Tmra).
This section provides information on installing the SuperServer 6014H-T into a rack unit with the rack rails provided. If the 6014H-T has already been mounted into a rack, you can skip ahead to Sections 2-5 and 2-6. There are a variety of rack units on the market, which may mean the assembly procedure will differ slightly.
Chapter 2: Server Installation Installing the Chassis Rails Two of the chassis rails (Chassis Rail 1) should have already been preattached - one to each side of the chassis. Attach the second set of chassis rails (Chassis Rail 2) directly to the chassis with the screws provided. Chassis Rail 2 should be positioned just behind Chassis Rail 1 (see Figure 2-2).
UPER ERVER 6014H-T Manual Installing the Server into the Rack You should now have rails attached to both the chassis and the rack unit. The next step is to install the server into the rack. Do this by lining up the rear of the chassis rails with the front of the rack rails.
Chapter 2: Server Installation Installing the Server into a Telco Rack If you are installing the SuperServer 6014H-T into a Telco type rack, follow the directions given on the previous pages for rack installation. The only difference in the installation procedure will be the positioning of the rack brackets to the rack.
ERVER 6014H-T Manual Checking the Serverboard Setup After you install the 6014H-T in the rack, you will need to open the unit to make sure the serverboard is properly installed and all the connections have been made. 1. Accessing the inside of the 6014H-T (see Figure 2-5) First, release the retention screws that secure the unit to the rack.
Figure 2-5. Accessing the Inside of the SuperServer 6014H-T (with optional front bezel shown) Checking the Drive Bay Setup Next, you should check to make sure the peripheral drives and the Serial ATA drives have been properly installed and all connections have been made.
Page 26
UPER ERVER 6014H-T Manual 4. Check the airfl ow Airfl ow is provided by two heavy duty 10-cm blower fans. The system compo- nent layout was carefully designed to direct the airfl ow to the components that generate the most heat. Note that all power and data cables have been routed in such a way that they do not block the airfl...
System Interface Overview There are several LEDs on the control panel as well as others on the Serial ATA drive carriers to keep you constantly informed of the overall status of the system as well as the activity and health of specifi c components. There are also two but- tons on the chassis control panel and an on/off switch on the power supply.
UPER ERVER 6014H-T User's Manual Control Panel LEDs The control panel located on the front of th SC813T-500 chassis has fi ve LEDs. These LEDs provide you with critical information related to different parts of the system. This section explains what each LED indicates when illuminated and any corrective action you may need to take.
HDD: Indicates IDE channel activity. On the SuperServer 6014H-T this light indicates SATA and/or CD-ROM drive activity when fl ashing. Power: Indicates power is being supplied to the system's power supply units. This LED should normally be illuminated when the system is operating.
Electrical Safety Precautions Basic electrical safety precautions should be followed to protect yourself from harm and the SuperServer 6014H-T from damage: Be aware of the locations of the power on/off switch on the chassis as well as the room's emergency power-off switch, disconnection switch or electrical outlet.
General Safety Precautions Follow these rules to ensure general safety: Keep the area around the SuperServer 6014H-T clean and free of clutter. The SuperServer 6014H-T weighs approximately 38 lbs (17.3 kg) when fully loaded. When lifting the system, two people at either end should lift slowly with their feet spread out to distribute the weight.
ESD Precautions Electrostatic discharge (ESD) is generated by two objects with different electrical charges coming into contact with each other. An electrical discharge is created to neutralize this difference, which can damage electronic com ponents and printed circuit boards. The following measures are generally suffi cient to neutralize this difference before contact is made to protect your equipment from ESD: Use a grounded wrist strap designed to prevent static discharge.
ERVER 6014H-T Manual Operating Precautions Care must be taken to assure that the chassis cover is in place when the 6014H-T is operating to ensure proper cooling. Out of warranty damage to the 6014H-T system can occur if this practice is not strictly followed.
Advanced Serverboard Setup This chapter covers the steps required to install processors and heatsinks to the X6DHR-TG serverboard, connect the data and power cables and install add-on cards. All serverboard jumpers and connections are described and a layout and quick reference chart are included in this chapter. Remember to close the chas- sis completely when you have fi...
UPERSERVER 6014H-T User’s Manual Processor and Heatsink Installation When handling the processor package, avoid placing direct pressure on the label area of the fan. Also, do not place the serverboard on a conductive surface, which can damage the BIOS battery and prevent the system from booting up.
Page 37
5. Screw in two diagonal screws until just snug (do not fully tighten), then do the same with the remaining two diagonal screws. Finish by fully tightening all four screws (see Figure 5-2). 6. If installing two processors, repeat these steps to install the second processor in the CPU #2 slot.
UPERSERVER 6014H-T User’s Manual Connecting Cables Now that the processors are installed, the next step is to connect the cables to the serverboard. These include the data (ribbon) cables for the peripherals and control panel and the power cables. Connecting Data Cables The ribbon cables used to transfer data from the peripheral devices have been carefully routed in preconfi...
Connecting the Control Panel JF1 contains header pins for various front control panel connectors. See Figure 5-3 for the pin locations of the various front control panel buttons and LED indi- cators. Please note that even and odd numbered pins are on opposite sides of each header.
Figure 5-4 below for the colors and locations of the various I/O ports. Figure 5-4. Rear Panel I/O Ports Installing Memory Note: Check the Supermicro web site for recommended memory modules. Exercise extreme care when installing or removing DIMM modules to prevent any possible damage. Also note that the memory is inter- leaved to improve performance (see step 1).
Page 41
Memory Support The X6DHR-TG supports up to 32 GB of DDR266 or up to 16 GB of DDR333 SDRAM. You should not mix DIMMs of different sizes and speeds. See Figure 5-5 for installing and removing memory modules. Memory Speed Jumpers Depending on what speed of memory you use, you may need to change the J4F4 and J4F5 (Memory Speed Select) jumpers.
PCI-X add-on card (any speed) and the CSE-RR1U-XLP fi ts into the 100 MHz PCI-X slot to support one low profi le (half-height, half-length) PCI-X add-on card (either 100 or 66 MHz). In additiona, two optional riser cards may be used with the 6014H-T, as de- scribed below. Riser Card...
Connector Defi nitions ATX Power Connection The power supply connector meets the SSI (Superset ATX) 20-pin specifi - cation. Make sure that the orientation of the connector is correct. See the table on the right for pin defi nitions. PWR_SEC Connection In addition to the Primary ATX power connector (above), the Secondary 12v 8-pin J15 connector (J38) must...
UPERSERVER 6014H-T User’s Manual HDD LED The HDD (IDE Hard Disk Drive) LED connection is located on pins 13 and 14 of JF1. Attach the IDE hard drive LED cable to display disk activity. Refer to the table on the right for pin defi...
Reset Button The Reset Button connection is lo- cated on pins 3 and 4 of JF1. Attach it to the hardware reset switch on the computer case. Refer to the table on the right for pin defi nitions. Power Button The Power Button connection is located on pins 1 and 2 of JF1.
UPERSERVER 6014H-T User’s Manual Serial Ports The COM1 serial port is located beside the mouse port. COM2 is a header on the serverboard (see serverboard layout for location). See the table on the right for pin defi nitions. Power Fail Header...
Extra Universal Serial Bus Headers Two additional USB headers (USB2/3) are located at JD2 on the serverboard. These are included for connection to the ports on the front of the chassis. A USB cable (not included) is needed for the connection. See the table on the right for pin defi...
UPERSERVER 6014H-T User’s Manual Wake-On-LAN The Wake-On-LAN header is desig- nated JWOL. See the table on the right for pin defi nitions. You must enable the LAN Wake-Up setting in BIOS to use this feature. You must also have a LAN card with a Wake- on-LAN connector and cable.
Jumper Settings Explanation of Jumpers To modify the operation of the serverboard, jumpers can be used to choose between optional settings. Jumpers create shorts between two pins to change the function of the connector. Pin 1 is identifi ed with a square solder pad on the printed circuit board.
UPERSERVER 6014H-T User’s Manual JLAN Enable/Disable Change the setting of jumper JPL1 to enable or disable the onboard GLAN ports (JLAN1 and JLAN2) on the serverboard. See the table on the right for jumper settings. The default setting is enabled...
3rd Power Supply Fail Detect Enable/Disable The system can notify you in the event of a power supply failure. This feature assumes that three power supply units are installed in the chassis with one act- ing as a backup. If you only have one or two power supply units installed, you should disable this (the default setting) with JP13 to prevent false alarms.
UPERSERVER 6014H-T User’s Manual 5-11 Floppy and Hard Drive Connections Note the following when connecting the fl oppy and hard disk drive cables: • The fl oppy disk drive cable has seven twisted wires. • A red mark on a wire typically designates the location of pin 1.
IDE Connectors There are no jumpers to confi g- ure the onboard IDE#1 and #2 connectors. See the table on the right for pin defi nitions. Chapter 5: Advanced Serverboard Setup IDE Drive Connectors Pin Defi nitions (J5, J6) Pin# Defi...
Advanced Chassis Setup This chapter covers the steps required to install components and perform mainte- nance on the SC813T-500 chassis. For component installation, follow the steps in the order given to eliminate the most common problems encountered. If some steps are unnecessary, skip ahead to the next step. Tools Required The only tool you will need to install components and perform maintenance is a Philips screwdriver.
UPER ERVER 6014H-T Manual Figure 6-1. Chassis: Front and Rear Views Slim CD-ROM Drive Power Supply Module USB Ports Mouse/Keyboard Control Panel The control panel (located on the front of the chassis) must be connected to the JF1 connector on the serverboard to provide you with system status indications.
Replace the failed fan with an identical 10-cm, 12 volt fan (available from Supermicro: p/n FAN-0059). Install the new fan in its proper place in the chas- sis by positioning it on the two mounting posts. Secure the fan to the chassis with the screws you removed previously, then attach the fan wires to the same chassis fan header you removed it from.
UPER ERVER 6014H-T Manual 10-cm Blower Fans Figure 6-2. System Cooling Fans (with optional front bezel shown) Drive Bay Installation/Removal Removing the Front Bezel If your system has a front bezel (optional) attached to the chassis, you must fi rst remove it to gain access to the drive bays.
CD-ROM/Floppy Disk Drives: For installing/removing a CD-ROM or fl oppy disk drive, you will need to gain access to the inside of the 6014H-T by removing the top cover of the chassis. Proceed to the "CD-ROM and Floppy Drive Installation"...
UPER ERVER 6014H-T Manual Serial ATA Drive Installation 1. Mounting a Serial ATA drive in a drive carrier The Serial ATA drives are mounted in drive carriers to simplify their installation and removal from the chassis. These carriers also help promote proper airfl ow for the Serial ATA drive bays.
Page 63
2. Installing/removing hot-swap SATA drives The SATA drive carriers are all easily accessible at the front of the chassis. These hard drives are hot-pluggable, meaning they can be removed and installed without powering down the system. To remove a carrier, push the release button located beside the drive LEDs.
The top cover of the chassis must be opened to gain full access to the CD-ROM and fl oppy drive bays. The 6014H-T accomodates only slim-line CD-ROM drives. Side mounting brackets are needed to mount a slim-line CD-ROM drive in the 6014H-T server.
If the power supply unit fails, the system will shut down and you will need to replace the unit. Replacement units can be ordered directly from Supermicro (see contact information in the Preface). As there is only one power supply unit in the 6014H-T, power must be completely removed from the server before removing and replacing the power supply unit for whatever reason.
Page 66
UPER ERVER 6014H-T Manual Figure 6-6. Removing/Replacing the Power Supply 6-10...
When an option is selected in the left frame, it is highlighted in white. Often a text message will accompany it. (Note that BIOS has default text messages built in. Supermicro retains the option to include, omit, or change any of these text mes- sages.) Options printed in Bold are the default settings.
UPERSERVER 6014H-T User’s Manual Running Setup *Default settings are in bold text unless otherwise noted. The BIOS setup options described in this section are selected by choosing the ap- propriate text from the main BIOS Setup screen. All displayed text is described in this section, although the screen display is often all you need to understand how to set the options (see on next page).
Chapter 7: BIOS Main BIOS Setup Menu Main Setup Features System Time To set the system date and time, key in the correct information in the appropriate fi elds. Then press the <Enter> key to save the data. System Date Using the arrow keys, highlight the month, day and year fi...
Page 70
UPERSERVER 6014H-T User’s Manual Legacy Diskette A This setting allows the user to set the type of fl oppy disk drive installed as diskette A. The options are Disabled, 360Kb 5.25 in, 1.2MB 5.25 in, 720Kb 3.5 in, 1.44/1.25MB, 3.5 in and 2.88MB 3.5 in.
Page 71
Chapter 7: BIOS Type Selects the type of IDE hard drive. The options are Auto (allows BIOS to automatically determine the hard drive's capacity, number of heads, Sectors, Maximum Capacity, LBA Format, ect.). Enter a number from 1-39 to select a predetermined type of hard drive, CD-ROM and ATAPI Removable.
Page 72
UPERSERVER 6014H-T User’s Manual Multi-Sector Transfers Select the number of transfer sectors. The options are Disabled, 2, 4, 6, 8 and 16 Sectors. LBA Mode Control This item determines whether Phoenix BIOS will access the IDE Primary Master Device via LBA mode. The options are Disabled and Enabled.
Chapter 7: BIOS Advanced Setup Choose Advanced from the Phoenix BIOS Setup Utility main menu with the arrow keys. You should see the following display. The items with a triangle beside them have sub menus that can be accessed by highlighting the item and pressing <Enter>. Options for PIR settings are displayed by highlighting the setting option using the arrow keys and pressing <Enter>.
Page 74
UPERSERVER 6014H-T User’s Manual ACPI Mode Use the setting to determine if you want to employ ACPI (Advanced Confi guration and Power Interface) power management on your system. The options are Yes and No. Power Button Behavior If set to Instant-Off, the system will power off immediately as soon as the user hits the power button.
Page 75
Chapter 7: BIOS Cache Base 0-512K If enabled, this feature will allow the data stored in the base memory area: block 0-512K to be cached (written) into a buffer, a storage area in the Static DRM (SDROM) or written into L1, L2, L3 cache inside the CPU to speed up CPU operations .
Page 76
UPERSERVER 6014H-T User’s Manual Discrete MTRR Allocation If enabled, MTRRs (-Memory Type Range Registers) are confi gured as distinct, separate units and cannot be overlapped. If enabled, the user can achieve better graphic effects when using a Linux graphic driver that requires the write- combining confi...
Page 77
PCI-X 133MHz Slot #1/Slot#2, PCI-Expx8 Slot#1/ Slot#2 Access the submenu for each of the settings above to make changes to the following: Option ROM Scan When enabled, this setting will initialize the device expansion ROM. The options are Enabled and Disabled. Enable Master This setting allows you to enable the selected device as the PCI bus master.
Page 78
UPERSERVER 6014H-T User’s Manual Memory RAS Feature Control Select this option to enable the Memory RAS Feature Control The options are Miirroring, Sparing and Standard. Clock Spectrum Feature If "Enabled", BIOS will monitor the level of Electromagnetic Interference caused by the components and will attempt to decrease the interference whenever needed.
Page 79
Advanced Processor Options Access the submenu to make changes to the following settings. CPU Speed This is a display that indicates the speed of the installed processor. Hyper-threading This setting allows you to Enable or Disable the function of hyper-threading. Enabling hyper-threading results in increased CPU performance.
Page 80
UPERSERVER 6014H-T User’s Manual KBC Clock Input This setting allows you to select clock frequency for KBC. The options are 6MHz, 8MHz, 12MHz and 16MHz. On-board COM 1 This setting allows you to assign control of serial port A. The options are Enabled (user defi...
Page 81
Chapter 7: BIOS DMI Event Logging Access the submenu to make changes to the following settings. Event Log Validity This is a display, not a setting, informing you of the event log validity. Event Log Capacity This is a display, not a setting, informing you of the event log capacity. View DMI Event Log Highlight this item and press <Enter>...
Page 82
UPERSERVER 6014H-T User’s Manual Console Redirection Access the submenu to make changes to the following settings. COM Port Address Specifi es to redirect the console to On-board COM A or On-board COM B. This setting can also be Disabled. BAUD Rate Select the BAUD rate for console redirection.
Page 83
Chapter 7: BIOS Hardware Monitor Logic CPU Temperature Threshold This option allows the user to set a CPU temperature threshold that will activate the alarm system when the CPU temperature reaches this pre-set temperature threshold. The options are 85 C, 90 C, 95 C and 100 Highlight this and hit <Enter>...
UPERSERVER 6014H-T User’s Manual Security Choose Security from the Phoenix BIOS Setup Utility main menu with the arrow keys. You should see the following display. Security setting options are displayed by highlighting the setting using the arrow keys and pressing <Enter>. All Security BIOS settings are described in this section.
Page 85
Chapter 7: BIOS Set Supervisor Password When the item "Set Supervisor Password" is highlighted, hit the <Enter> key. When prompted, type the Supervisor's password in the dialogue box to set or to change supervisor's password, which allows access to BIOS. Set User Password When the item "Set User Password"...
UPERSERVER 6014H-T User’s Manual Boot Choose Boot from the Phoenix BIOS Setup Utility main menu with the arrow keys. You should see the following display. Highlighting a setting with a + or - will expand or collapse that entry. See details on how to change the order and specs of boot devices in the Item Specifi...
Chapter 7: BIOS Exit Choose Exit from the Phoenix BIOS Setup Utility main menu with the arrow keys. You should see the following display. All Exit BIOS settings are described in this section. Exit Saving Changes Highlight this item and hit <Enter> to save any changes you made and to exit the BIOS Setup utility.
Page 88
UPERSERVER 6014H-T User’s Manual Save Changes Highlight this item and hit <Enter> to save any changes you made. You will remain in the Setup utility. 7-22...
Appendix A: BIOS POST Messages Appendix A BIOS POST Messages During the Power-On Self-Test (POST), the BIOS will check for problems. If a prob- lem is found, the BIOS will activate an alarm or display a message. The following is a list of such BIOS messages.
Page 90
UPERSERVER 6014H-T User’s Manual System CMOS checksum bad - Default confi guration used System CMOS has been corrupted or modifi ed incorrectly, perhaps by an application program that changes data stored in CMOS. The BIOS installed Default Setup Values. If you do not want these values, enter Setup and enter your own values.
Page 91
Appendix A: BIOS POST Messages System cache error - Cache disabled RAM cache failed and BIOS disabled the cache. On older boards, check the cache jumpers. You may have to replace the cache. See your dealer. A disabled cache slows system performance considerably. CPU ID: CPU socket number for Multi-Processor error.
Page 92
UPERSERVER 6014H-T User’s Manual Fixed Disk n Fixed disk n (0-3) identifi ed. Invalid System Confi guration Data Problem with NVRAM (CMOS) data. I/O device IRQ confl ict I/O device IRQ confl ict error. PS/2 Mouse Boot Summary Screen: PS/2 Mouse installed.
Page 93
Appendix A: BIOS POST Messages Parity Check 2 nnnn Parity error found in the I/O bus. BIOS attempts to locate the address and display it on the screen. If it cannot locate the address, it displays ????. Press <F1> to resume, <F2> to Setup, <F3> for previous Displayed after any recoverable error message.
Appendix B BIOS POST Codes This section lists the POST (Power On Self Test) codes for the PhoenixBIOS. POST codes are divided into two categories: recoverable and terminal. Recoverable POST Errors When a recoverable type of error occurs during POST, the BIOS will display an POST code that describes the problem.
Page 96
UPERSERVER 6014H-T User’s Manual POST Code Description 8254 timer initialization 8237 DMA controller initialization Reset Programmable Interrupt Controller 1-3-1-1 Test DRAM refresh 1-3-1-3 Test 8742 Keyboard Controller Set ES segment register to 4 GB Auto size DRAM Initialize POST Memory Manager...
Page 97
POST Code Description Test RAM between 512 and 640 kB Test extended memory Test extended memory address lines Jump to UserPatch1 Confi gure advanced cache registers Initialize Multi Processor APIC Enable external and CPU caches Setup System Management Mode (SMM) area Display external L2 cache size Load custom defaults (optional) Display shadow-area message...
Page 98
UPERSERVER 6014H-T User’s Manual POST Code Description Check for SMART Drive (optional) Shadow option ROMs Set up Power Management Initialize security engine (optional) Enable hardware interrupts Determine number of ATA and SCSI drives Set time of day Check key lock...
Page 99
POST Code Description Re-map I/O and memory for PCMCIA Initialize digitizer and display message Unknown interrupt The following are for boot block in Flash ROM POST Code Description Initialize the chipset Initialize the bridge Initialize the CPU Initialize system timer Initialize system I/O Check force recovery boot Checksum BIOS ROM...
After all the hardware has been installed, you must fi rst confi gure the Adaptec Embedded Serial ATA RAID Driver before you install the Windows operating system. The necessary drivers are all included on the Supermicro bootable CDs that came packaged with your motherboard. (For Adaptec's SCSI Host RAID Utility, please refer to the CDs that came with your motherboard.)
Page 102
I/O throughput and providing data acces- sibility regardless of a single disk failure. By incorporating Adaptec Embedded Serial ATA into the motherboard design, Supermicro offers the user the benefi ts of SATA RAID without the high costs associated with RAID hardware.
Page 103
Appendix C: Software Installation Using the Array Confi guration Utility (ACU) The Array Confi guration Utility (ACU) enables you to create, manage, and delete arrays from the controller’s BIOS, add and delete spare drives, and initialize drives. During the system startup, press the Ctrl and A keys simultaneously, and the main menu will appear.
Page 104
UPERSERVER 6014H-T User’s Manual Managing Arrays Select this option to view array properties and delete arrays. The following sec- tions describe the operations Of "Managing Arrays". To select this option, use the arrow keys and the Enter key to select Managing...
Page 105
Viewing Array Properties To view the properties of an existing array: 1. At the BIOS prompt, press Ctrl+A. 2. From the ARC menu, select Array Confi guration Utility (ACU). 3. From the ACU menu, select Manage Arrays (as shown on the previous screen.) 4.
Page 106
UPERSERVER 6014H-T User’s Manual Creating Arrays Before creating arrays, make sure the disks for the array are connected and installed in your system. Note that disks with no usable space, or disks that are un-initialized are shown in gray and cannot be used. See Initializing Disk Drives.
Page 107
Appendix C: Software Installation Assigning Array Properties Once you've create a new array, you are ready to assign properties to the ar- ray. Caution: Once the array is created and its properties are assigned, you cannot change the array properties using the ACU. You will need to use the Adaptec Storage Manager - Browser Edition.
Page 108
UPERSERVER 6014H-T User’s Manual 4. The item "Create RAID via" allows you to select between the different meth- ods of creating RAID 0 and RAID 1. The following table gives examples of when each is appropriate. 5. When fi nished, press Done (as shown on the following screen).
Page 109
Appendix C: Software Installation Notes 1. Before adding a new drive to an array, back up any data contained on the new drive. Otherwise, all data will be lost. 2. If you stop the build or clear process on a RAID 1 from ACU, you can restart it by pressing Ctrl+R.
Page 110
UPERSERVER 6014H-T User’s Manual Adding a Bootable Array 1. From the Main menu, select Manage Arrays. 2. From the list of arrays, select the array you want to make bootable and press Ctrl+B. 3. Enter Y to create a bootable array when the following message is displayed: "This will make all other existing bootable array non-bootable.
Page 111
Appendix C: Software Installation Adding/Deleting Hotspares Note: In order to rebuild a RAID (RAID 0 or RAID 1), you need to add a new HDD as a hotspare. 1. Turn on your computer and press Ctrl+A as prompted to access the ARC Utility.
Page 112
UPERSERVER 6014H-T User’s Manual Initializing Disk Drives If an installed disk does not appear in the disk selection list for creating a new array or if it appears grayed out, you may have to initialize it before you can use it as part of an array.
Page 113
Appendix C: Software Installation 5. Repeat Step 4 so that both drives to be initialized are selected (as shown on the following screen). C-13...
Page 114
UPERSERVER 6014H-T User’s Manual 6. Press Enter. 7. Read the warning message as shown on the screen below. 8. Make sure that you have selected the correct disk drives to initialize. If cor- rect, type Y to continue. Rebuilding Arrays Note 1: Rebuilding applies to Fault Tolerant arrays (RAID 1) only.
Appendix C: Software Installation Using the Disk Utilities The Disk Utilities enable you to format or verify the media of your Serial ATA hard disks. To access the disk utilities: 1. Turn on your computer and press Ctrl+A when prompted to access the ARC utility.
Page 116
UPERSERVER 6014H-T User’s Manual To Exit Adaptec RAID Confi guration Utility 1. Once you have completed RAID array confi gurations, press ESC to exit. The following screen will appear. 2. Press Yes to exit the Utility. For more information regarding the Adaptec RAID Utility, please refer to Adaptec's User's Guide in the CD included in your shipping package.
Page 117
Appendix C: Software Installation C-2 Installing Intel's ICH5R Driver by Adaptec and Windows OS 1. Insert Supermicro's bootable CD that came with the package into the CD Drive during the system reboot. The "Super Micro Driver Diskette Maker" screen will appear.
Page 118
UPERSERVER 6014H-T User’s Manual C-3 Installing Other Software Programs and Drivers Installing Other Drivers After you've installed the Windows Operating System, a screen (as shown in Figure C-1) will appear. You are now ready to install additional software programs and drivers. To install these software programs and drivers, click the icons to the right of these items.
Page 119
Appendix C: Software Installation Supero Doctor III The Supero Doctor III program is a web-based management tool that offers both remote and local management tools. The local management application is called SD III Client. The Supero Doctor III program included on the CDROM that came with your motherboard allows you to monitor the environment and operations of your system.
Page 120
Figure C-3. Supero Doctor III: Remote Control Display Note: SD III Software Revision 1.0 can be downloaded from our Web site at: ftp://ftp.supermicro.com/utility/Supero_Doctor_III/. You can also download the SDIII User's Guide at: http://www.supermicro.com/PRODUCT/Manuals/SDIII/ UserGuide.pdf. For Linux, we recommend using Supero Doctor II.
Appendix D: System Specifi cations Appendix D System Specifi cations Processors Single or dual Intel® Xeon™ 604-pin processors to 3.60 GHz at a front side (system) bus speed of 800 MHz. Note: Please refer to our web site for a complete listing of supported processors. Chipset Intel E7520 chipset BIOS...
Page 122
UPER ERVER 6014H-T Manual Expansion Slots (provided with included riser cards) One (1) 64-bit 133 MHz standard size PCI-X slot and one (1) 64-bit 66 MHz low profi le PCI-X slot (with CSE-RR1U-X and CSE-RR1U-XLP riser cards) Motherboard Model: X6DHR-TG (Extended ATX form factor)
Page 123
Appendix D: System Specifi cations Regulatory Compliance Electromagnetic Emissions: FCC Class B, EN 55022 Class B, EN 61000-3-2/-3-3, CISPR 22 Class B Electromagnetic Immunity: EN 55024/CISPR 24, (EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-8, EN 61000-4-11) Safety: EN 60950/IEC 60950-Compliant, UL Listed (USA), CUL Listed (Canada), TUV Certifi...