Installing your Freestanding Cooker
Bringing it all together
Gas Conversion (NG to U-LPG)
Parts needed
- Test Point Assembly
- Auxiliary Jet 00.53mm
- Wok Jet 01.00mm
Converting to a different gas type
CONVERSION TO A DIFFERENT GAS TYPE MUST BE
CARRIED OUT BY A SUITABLY QUALIFIED GAS SAFE
REGISTERED INSTALLER
Changing the jets
1. Remove pan supports, burner heads and caps.
2. Use a size 7 socket wrench to unscrew and remove
the jets, replacing them with those supplied in the
conversion kit. Ensure you use the correct jet for the
corresponding burner.
3. Reassemble the burner heads, caps and pan
supports.
4. Fit the Gas type label supplied in the conversion kit
next to the gas connection point and remove the
existing label.
or online at www.bush-support.co.uk If you still require further assistance, call one of our experts on 01759 487838.
- ULPG Gas Type label
- Semi-Rapid Jet 00.68mm
- Rapid / Fish Jet 00.88mm
Setting the minimum level
1. Light one of the burners and turn the tap to
minimum flame.
2. Remove the corresponding control knob.
3. Use a thin blade screwdriver to turn the by-pass
screw located above left of the gas valve shaft as
shown right. Turn the by-pass screw fully clockwise.
The result should be a small, stable flame which is
uniform around the entire burner ring. If not, turn the
by-pass screw anti-clockwise until satisfied with the
flame.
4. Check that the burner does not go out when the tap
is turned quickly from the maximum to the minimum
position.
5. Repeat for each burner.