General

2
General
The CWL -2-325 and the CWL -2-325 Plus is a ventilation unit for the balanced ventilation of dwellings
with heat recovery.
Features:
– Maximum capacity 325 m³/h
– High return plastic heat exchanger
– Filters ISO Coarse 60%
– Modular electric preheater
– Automatic bypass valve
– Touchscreen
– Adjustable air quantity
– Filter indication on the appliance and the possibility of a filter indication on the multiple switch
– An intelligent frost protection including modular preheater
– Low sound level
– Constant flow control
With a Plus pcb more functions/connection possibilities (® Plus version page 11). These installation
instructions describe both the standard CWL -2-325 and the CWL -2-325 Plus.
The CWL -2-325 and the CWL -2-325 Plus are available in Left-hand and Right-hand versions; it is not
possible to convert the left and right-hand models into one another
For the correct connection ducts and dimensions (® Connections and dimensions page 8).
The appliance comes ready to plug in with a 230 V mains plug .