Lamp/Maintenance Indicators; Before Calling For Service - Sharp PG-D120U Operation Manual

Hide thumbs Also See for PG-D120U:
Table of Contents

Advertisement

Lamp/Maintenance Indicators

Lamp
The Lamp has a finite operating life. The lamp for this projector has a usable life of 2000 cumulative hours. This
number may differ, however, depending on the ambient conditions.
1. When the lamp is nearing the end of its operating life, the picture and color quality will deteriorate. If the lamp is
used for more than 1900 hours, the LAMP REPLACEMENT indicator will light red and "LAMP" will flash in
yellow letters on the screen when you turn the projector on to alert you that it is time to replace the lamp. In this
situation, replace the lamp (See pages 32 and 33).
Note:
The lamp usage time can be checked at the On-Screen display. (See page 27.)
Caution: Once you are alerted that the lamp requires replacement, be sure to replace the lamp.
2. When the number of hours the lamp is used reaches 2000, the power automatically turns off and the projector
enters the standby condition. If you turn on the power after the lamp has been used for 2000 hours, "LAMP" will
flash on screen in red letters for five minutes and then the power will turn off.
3. If the new lamp does not light after replacement, take your projector to the nearest Authorized Sharp Industrial
LCD Products Dealer or Service Center for repair.
4. Intense light hazard. Do not attempt to look into the aperture and lens while the projector is operating.
Maintenance Indicators
POWER
LAMP
REPLACEMENT
LAMP
indicator
TEMPERATURE
TEMP.
indicator
Warning Indicator
TEMPERATURE
The internal
indicator
temperature is
abnormally high.
The lamp does not
LAMP REPLACE-
light up.
MENT indicator
The lamp requires
replacement.
Notes:
If the TEMPERATURE indicator comes on, solve the problem and then wait until the projector has cooled down completely
before turning the power back on. (At least 5 minutes.)
When the power is turned off and then turned on again, as during a brief rest, the LAMP replacement indicator may be triggered,
preventing the power from going on. When this happens, take the power plug out of the AC outlet and put it back in again.

Before Calling for Service

Problem
No picture and no sound.
Sound is heard but no picture
appears.
Color is faded or poor.
Picture is blurred.
Picture appears but no sound is
heard.
An unusual sound is occasionally heard
from the cabinet.
Maintenance indicator lights up.
The warning lights on the projector indicate problems inside the projector.
There are two warning lights–a TEMPERATURE indicator which warns that the
projector is too hot, and a LAMP REPLACEMENT indicator which lets you know
when to change the bulb.
If a problem occurs, either the TEMPERATURE indicator or the LAMP REPLACE-
MENT indicator will light up red, and the power will shut off. After turning off the
power, follow the procedures given below.
Symptom
Problem
Blocked air intake.
Clogged air filter.
Cooling fan breakdown.
Internal circuit failure.
Burnt-out lamp.
Lamp circuit failure.
The lamp has been used
for over 1900 hours.
The projector AC cord is not plugged into the AC wall outlet.
The main power button is not pressed.
The input is wrong. (See page 22.)
Cables improperly connected to rear panel of the projector. (See pages 14, 15, 16 and 17.)
Remote control batteries have run down. (See page 7.)
The optional cable for the remote control is properly inserted.
The main power of the remote control is not turned on.
The remote control's MOUSE/ADJUSTMENT switch is set to MOUSE.
The usable life of the lamp has been reached. (See page 31.)
Cables improperly connected to rear panel of the projector. (See pages 14, 15, 16 and 17.)
The BRIGHTNESS and PICTURE adjustments are set to minimum position. (See page 23.)
The COLOR and TINT adjustments are not correct. (See page 23.)
Adjust the focus. (See page 9.)
The projection distance is too long or too short to allow for proper focus. (See page 10.)
Cables improperly connected to rear panel of the projector. (See pages 14, 15, 16 and 17.)
Volume is set to minimum. (See pages 22.)
If the picture is normal, the sound is due to cabinet shrinkage caused by temperature changes. This
will not affect operation or performance.
Refer to "Lamp/Maintenance Indicators" on page 31.
Possible Solution
Relocate projector to a proper location.
Clean the filter.
(See page 30.)
Take the projector to your nearest Autho-
rized Sharp Industrial LCD Products Dealer
or Service Center for repair.
Carefully replace the lamp.
Take the projector to your nearest Autho-
rized Sharp Industrial LCD Products Dealer
or Service Center for repair.
Check
E-31

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pg-d100u