The analog input channels can be jumper-configured to accept voltages in any one
of three ranges. There are two bipolar ranges and one unipolar range.
Bipolar Ranges
The
J3B selects the &lOV bipolar range. Table 2-7 shows the options.
Table 2-7. Voltage Type and Voltage Range Selection Options
Input Range
Unipolar:
0-10V
I
Bipolar:
2.6.4
INPUT GAIN RANGE SELECTION
2.6.4.1
Programmable Gain Selection
(J15 & J19; J14 & J18; J16 & J20)
The gain for each input channel is individually programmable over any one of three
possible gain ranges.
three pairs of jumpers (J15 & J19;
gains (within the selected range) are determined by the user and written to on-
board Gain RAM during an input initialization procedure (See Section 3.3.3).
Thereafter, any time an input is converted (analog-to-digital), it will automatically
apply the gain factor for which it was previously programmed.
gain ranges are:
Range 1:
Range 2:
Range 3:
Artisan Scientific - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisan-scientific.com
Install
J3A, J5A
J3A, J5B
J3B, J5B
(XVME-500/590-2, XVME-500/590-3)
First, the required range is selected by configuring one of
J14 & J18; or
Three Input Gain Ranges
2-13
Unioolar
Range
0 to 10V
Remove
J3B, J5B
J3B, J5A
J3A, J5A
J16 & J20). Next, the specific
1, 2, 5, or 10
4, 8, 20, or 40
10, 20, 50, or 100
The three input