Analog input module

Advertisement

XVME-500/590 Manual
February, 1988
Characteristic
Programmable Gain (versions 2 & 3)
Range 1
Range 2
Range 3
Fixed Gain (version 3)
Resistor
programmable
Maximum Input Voltage
Power on
Power off
Input Impedance
w 1OM ohm resistor
w/o 1OM ohm resistor
Bias Current
Input
Capacitance
Operating Common Mode Voltage
Speed
Conversion Time
versions 1 & 2
version 3
Throughput
version 1
version 2
version 3
Settling
Time
version 1
versions 2 & 3
External
Trigger-to-Sample
Artisan Scientific - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisan-scientific.com
Table 1-2 (cont'd)
Frequency
xl, x10, x100, xl000
12-bit
25uSec
10uSec
20KHz
28.5KHz
50KHz
25uSec
10uSec
10 or 20uSec
1-8
Specification
1, 2, 5, or 10
4, 8, 20 or 40
10, 20, 50, or 100
1OM ohm min.
1OOM ohm min.
+ 1 OOnA max.
1 OOpf max.
14v
8-bit
17uSec
6.8uSec
23.8KHz
37KHz
59.5KHz
25uSec
10uSec
10, 25uSec