TRIMLINE INSTALLATION INSTRUCTIONS
TRIMLINE INSTALLATIE VOORSCHRIFT
TRIMLINE INSTRUCTIONS DE INSTALLATION
TRIMLINE INSTALLATIONSVEJLEDNING
TRIMLINE INSTRUCCIONES DE INSTALACIÓN
TRIMLINE MONTAGEANLEITUNGEN
Trimline 6345 Panorama/Corner
Trimline 3863 Panorama/Corner/Front
Trimline 6345 Panorama/Hoek
Trimline 3863 Panorama/Hoek/Front
Trimline 6345 Panorama/Coin
Trimline 3863 Panorama/Coin /Frontal
Trimline 6345 Panorama/Hjørne
Trimline 3863 Panorama/Hjørne/Front
Trimline 6345 Panorama/Ángulo
Trimline 3863 Panorama/Ángulo/Frente
Trimline 6345 Panorama/Ecke
Trimline 3863 Panorama/Ecke/Front
(1053/ 1054/1055)
(1070/1071/1072/1073)
(1053/ 1054/1055)
(1070/1071/1072/1073)
(1053/ 1054/1055)
(1070/1071/1072/1073)
(1053/ 1054/1055)
(1070/1071/1072/1073)
(1053/ 1054/1055)
(1070/1071/1072/1073)
(1053/1054/1055)
(1070/1071/1072/1073)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Trimline 6345 Panorama/Corner and is the answer not in the manual?

Questions and answers

Summary of Contents for Thermocet Trimline 6345 Panorama/Corner

  • Page 1 TRIMLINE INSTALLATION INSTRUCTIONS TRIMLINE INSTALLATIE VOORSCHRIFT TRIMLINE INSTRUCTIONS DE INSTALLATION TRIMLINE INSTALLATIONSVEJLEDNING TRIMLINE INSTRUCCIONES DE INSTALACIÓN TRIMLINE MONTAGEANLEITUNGEN Trimline 6345 Panorama/Corner (1053/ 1054/1055) Trimline 3863 Panorama/Corner/Front (1070/1071/1072/1073) Trimline 6345 Panorama/Hoek (1053/ 1054/1055) Trimline 3863 Panorama/Hoek/Front (1070/1071/1072/1073) Trimline 6345 Panorama/Coin (1053/ 1054/1055)
  • Page 2 INSTALLATION INSTRUCTIONS Trimline assortiment Trimline 6345 Panorama/Corner (1053/ 1054/1055) Trimline 3863 Panorama/Corner/Front (1070/1071/1072/1073)
  • Page 3: Table Of Contents

    TABLE OF CONTENTS INSTALLATION INSTRUCTIONS Page. 3 General instructions PLACING THE APPLIANCE Page. 4 Connection the gas lines Preparation and installation Installing gas control GV60 PLACING OPTIONAL CERAMIC LOG AND OPTIONAL PEBBLES SET Page. 6 Fitting the ceramic logs Fitting the optional pebbles set TECHNICAL DETAILS GV60 Page.
  • Page 4: Installation Instructions

    INSTALLATION INSTRUCTIONS The installation should be performed only by an authorized gasfitter 1.1 General instructions The gas fireplace must be installed, connected and inspected as a balanced flue fire by a qualified fitter, according to national, regional, and local standards and regulations. The flue system and the terminals in the outer wall or roof face must also meet the requirements outlined in the applicable standards and regulations.
  • Page 5: Placing The Appliance

    PLACING THE APPLIANCE "Concentric flue system" 2.1 Connection the gas lines You can determine where the gas pipes will be placed, depending on the positioning of the appliance. Ensure control equipment is not twisted during installation and there is no excessive tension. Accessibility of various connection pointsin relation to components need to be maintained.
  • Page 6: Placing Optional Ceramic Log And Optional Pebbles Set

    PLACING OPTIONAL CERAMIC LOG AND OPTIONAL PEBBLES SET 3.1 Fitting the Ceramic log set (see APPENDIX7) Mix the glowing material (lava granules) and spread them evenly over the burner and the burner plate so that they are just covered. Glowing embers can be placed here and there as decoration. Place the ceramic wood blocks in the correct order as shown on APPENDIX 7.
  • Page 7: Technical Details Gv60

    TECHNICAL DETAILS GV60 Gas valve type : Mertik GV60 Burner control : B6R R8U Ignition : Remote control operation and Piezo ignition Gas connection : 3/8 "(External) A = Gas inlet B = Gas outlet C = Thermocouple connection D = pilot burner connection Unit category : C11-C31-C91 Pilot flame...
  • Page 8: Instructions For Mertik Maxitrol Gv60 Gascontrol Page

    5. INSTRUCTIONS FOR MERTIK MAXITROL GV60 GASCONTROL WARNING It is forbidden to start up the unit if window (s) is not present or broken! Ensure that the fuel supplied to the unit is clean and free from particles and moisture. Before a gas supply pipe (new or existing) is connected to the main gas pipe at the gas meter and to the gas control block of the unit, clean and dry compressed air should been blown through it.
  • Page 9: Gas Technical Data Page

    7. GAS TECHNICAL DATA 6. GAS TECHNICAL DATA 1053/54/55 1053/54/55 1053/54/55 GASTYPE G30/31 COUNTRY NO/ES/PT/DE/IE/ ES/PT/IE/GB/BE/ NL/DE GB/BE/FR/IT/LV/ FR/LV/SI/EE/HU/ SI/SK/EE/HU/LT LT/PL/CY/MT CATEGORY I2H/I2E/I2E+ I3B/P, I3+ I2L/I2ELL PRIMAIRY AIR PRE PRESSURE mBar 20 mbar 30/50, 29/37 mbar 25/20 mbar BURNERPRESSURE HIGH mBar 19,2 28,5/36,3 24/ 19,2...
  • Page 10: Concentric Chimney Lay Out Page

    7. CONCENTRIC CHIMNEY LAY OUT...
  • Page 11: Concentric Flue System Page

    8. CONCENTRIC FLUE SYSTEM The concentric flue system is composed of an inner- and an outer tube. These tubes are concentrically arranged; through the inner tube, the combustion gases are evacuated and the fresh combustion air is supplied between the inner and outer tube. 8.1 Components of the concentric flue system.
  • Page 12: Installation Instructions Regarding Existing Flues

    8.3 Installation instructions regarding existing flues. (see APPENDIX 3) Instructions The flue gas exhaust system falls within category C91 and must be built in accordance with national rules and regulations and the instructions of the manufacturer, as specified in the documentation and installation instructions. This means, among other things, that the existing chimney must not be smaller than 150 mm round / square, but no larger than 200 mm, and not ventilated by grilles etc.
  • Page 13: Terminal Positions And Correct Functioning Page

    TERMINAL POSITIONS AND CORRECT FUNCTIONING Distance Dimensions Terminal position Distance to ventilation openings Local* Distance to ventilation openings Local* Distance to ventilation openings Local* Below a gutter soil pipes or drain pipes Below eaves Below carport, roof or balcony From Inner and outer corners From a vertical soil pipes or drain pipes Inside and outside of a corner Above an outside gas pressure regulator...
  • Page 14: Cleaning An Maintenance Page

    Hard (abrasive) sponges, steel wool, abrasives and cleaners with ammonia or acid (citric acid as well) Paper towels, ceramic cook top cleaner. Only use: water or suitable detergents. We advise our Thermocet cleaner. Procedure: Wear soft cotton gloves at all times.
  • Page 15: Troubleshooting List Mertik Gv60

    11. TROUBLESHOOTING LIST MERTIK GV60 ACTION Possible problem/cause Solution Option: wall switch START: Bent pin on switch, or cable Straighten pin, replace wall press ON button > wall switch not operating properly. switch or cable. works. Manual transmitter START: Manual transmitter battery Replace battery, 2x AAA 1.5V press both buttons to start low.
  • Page 16 No ACTION Possible problem/cause Solution Ignition components not operating Check connection between cable & IGN properly. electrode. Check IGN electrode spark gap. Check IGN electrode for discharge to ground (break in ceramic). Check IGN cable for damage Continuous spark Increase distance between IGN cable and all metal parts.
  • Page 17 No ACTION Possible problem/cause Solution Resistance in thermo Check cables and current circuit too high. connections in thermo current circuit. Magnet unit drops Not enough heat on Check position of pilot to (audible click) thermocouple. thermocouple and intensity of pilot flame. Motor turns to main Low voltage from Check connections and, if...