Combustion Parameters; Technical Data - Immergas HE COMBI INTERNAL Manual

Wall mounted heating only boiler
Table of Contents

Advertisement

3.17 COMBUSTION PARAMETERS.

Gas nozzle diameter
Supply pressure
Flue ow rate at nominal heat output
Flue ow rate at min heat output
CO
at Nom Q./Min.
2
CO with 0% O
at Nom Q /Min.
2
NO
with 0% O
at Nom Q /Min.
X
2
Flue temperature at nominal output
Flue temperature at minimum output

3.18 TECHNICAL DATA.

Heat input N G
Heat output NG
CH minimum heat output
Burner pressure maximum NG/LPG
Burner pressure minimum NG/LPG
Heat input LPG
Heat output LPG
CH minimum heat input
ie ncy 80/60 Nom./Min.
ie ncy 50/30 Nom./Min.
Heat loss at casing with burner On/
Heat loss at flue with burner On/O
Central heating circuit max. operating pressure
Central heating circuit max. operating temperature
Adjustable central heating temperature
System expansion vessel total volume
Expansion vessel factory-set pressure
Pressure relief setting
Expansion vessel capacity
Water content in generator
Head available with 1000 l/h ow rate
Internal pump head (kPa)
Hot water production heat output
Speci c ow rate (
t 25
C )
o
Domestic hot water circuit max. working pressure
Min. pressure (dynamic) domestic hot water circuit
Minimum D.H.W. ow rate
Weight of full boiler
Weight of empty boiler
Electrical connection
Power input
Installed electric power
Pump consumption
Fan power consumption
Equipment electrical system protection
NO
class
X
Weighted NO
X
Weighted CO
Type of appliance
- Flue temperature values refer to an air inlet
temperature of 15°C.
-
approved with the HE 30 COMBI INTERNAL,
components 60/100 and 80/125 mm.
25
NG (G20)
mm
1,40
kPa
1,0
kg/h
58
kg/h
59
%
7,75 / 3,30
ppm
55 / 11
mg/kWh
170 / 41
°C
67
°C
62
MJ/h (kW)
MJ/h (kW)
MJ/h (Kw)
kPa
kPa
MJ/h (kW)
MJ/h (kW)
MJ/h (kW)
%
%
%
%
kPa
°C
°C
l
bar
bar (psi)
L
l
kPa (m H
O)
2
MJ/h (kW)
l/min
kPa
kPa
l/min
kg
kg
V/Hz
A
W
W
W
-
-
mg/kWh
mg/kWh
V 4.7m
V12.2m
V 40m*
C12 /C32 / C42 / C52 / B22 / B32
- The max. sound level emitted during boiler
operation is < 55dBA. The sound level value is
referred to semianechoic chamber tests with
boiler operating at max. heat output, with
extension of flue gas exhaust system according
to product standards.
LPG (G30)
0,85
2,8
60
63
8,90 / 3,75
78 / 29
240 / 46
68
61
124,2 (36,2)
126 (34,9)
53.9 (14.9)
0.70/2.10
0.19/0.55
124.2 (36.2)
130 (34.9)
45,7 (14,9)
96,5 / 92,9
102,0 / 99,1
0,50 / 0,59
3,00 / 0,01
300
90
35 - 85
5,1
1
3 (44)
10
4,0
30,2 (3,1)
126 (34,9)
20
1000
30
1.5
49
45
230/50
1
175
95
65
IPX5D
3
110
81
H 3.0m
H 7.3m
H 20m*

Advertisement

Table of Contents
loading

This manual is also suitable for:

He combi external

Table of Contents