Boiler Shutdown; Restore Heating System Pressure; Draining The System; Decommissioning - Immergas HE COMBI INTERNAL Manual

Wall mounted heating only boiler
Table of Contents

Advertisement

C omando remoto remote control not
compatible.
is occurs in the case of an
incompatible connection to a remote control or
if there is a loss of communication between the
boiler and Comando Amico Remoto
remote control. Try the connection procedure
selector switch (12) to position (
the CAR
is still not detected on re-starting
V2
the boiler will switch to local operating mode,
i.e. using the controls on the boiler itself. If
t
his phenomenon occurs frequently, contact a
quali ed Hunt Heating servcie technician.
Signalling and diagnostics - Display of the
Comando Amico Remoto Remote Control
(CAR
) (Optional). During normal boiler
V2
functioning the Comando Amico Remoto
(CAR
) remote control display shows the room
V2
temperature value; in the case of malfunctioning
or anomaly, the display of the temperature is
replaced by the relative error code present in
the previous table.
Attention: if the boiler is in stand-by "
error "CON" will be displayed on the CAR
constantly so as not to loose the memorised
programs.

2.6 BOILER SHUTDOWN.

Disconnect the main selector switch (12) taking
it to position "
" (green indicator 1 o ),
disconnect the omni-polar switch external to the
boiler and close the gas cock upstream from the
appliance. Never leave the boiler switched on if
2.7 RESTORE HEATING SYSTEM
PRESSURE.
Periodically check the system water pressure.
between 1 and 1.2 bar.
If the pressure falls below 1 bar (with cool circuit)
restore normal pressure using the valve provided
by the maintenance technician.
Lower view.
N.B.:
If pressure values reach around 3 bar the safety
valve may be activated.
In this case contact a professional technician
(CAR
)
for assistance.
V2
V2
In the event of frequent pressure drops, contact
quali ed sta for assistance to eliminate the
). If
possible system leakage.

2.8 DRAINING THE SYSTEM.

To drain the boiler, use the special draining
valve (Fig. 2-2).
closed.
2.9
V2
has an anti-freeze function that switches the
V2
burner on automatically when the temperature
falls below 4°C (standard protection to minimum
temperature of -5°C). All information relative to
the anti-freeze protection is stated in Par. 1.3. In
order to guarantee the integrity of the appliance
and the domestic hot water heating system in
", code
zones where the temperature falls below zero,
V2
we recommend the central heating system is
protected using anti-freeze liquid. In the case
of prolonged inactivity (second case), we also
recommend that:
- the electric power supply is disconnected;
- the heating circuit and boiler domestic water
circuit must be drained. In systems that are
drained frequently,
out with suitably treated water to eliminate
hardness that can cause lime-scale.

2.10 DECOMMISSIONING.

In the event of permanent shutdown of the boiler,
ensure that the electrical, water and gas supply
/ EXT
ling must be carried
Key:
16
1 - System draining valve
Fig. 2-2