7-5.

Troubleshooting For Malfunctions

(1)
No power
Check
Has the power cord been securely plugged
into the power outlet?
Yes
Has the power cord been securely con-
nected to the printer?
Yes
Has the Power Switch (S1) been turned
ON?
Yes
Has the fuse (F1 or F2) in the Power Unit
(PU1) blown?
Cause
Laser diode malfunction
SOS Sensor malfunction
(2)
FATAL ERROR 02: Polygon Motor
Cause
Polygon Motor malfunction
(3)
FATAL ERROR 01: Main Motor
Cause
Does the Main Motor (M1) turn when the
Power Switch is turned ON?
(4)
FATAL ERROR 07: Fuser Temperature low/
FATAL ERROR 06: Fuser Warm up/
FATAL ERROR 08: Fuser Overheat
Cause
Does the error message appear after the
printer has completed warming up?
No
Is the Fusing Unit warm?
No
PagePro 1200 Series Troubleshooting
Remedy
Plug the power cord into the power outlet.
No
Plug in the power cord.
No
Turn ON the Power Switch.
No
Replace PU1 or Controller Board.
No
Replace the fuse (F1 or F2).
Yes
Remedy
Replace the Print Head Unit.
Replace the Controller Board.
Remedy
Replace the Print Head Unit.
Replace the Controller Board.
Remedy
Replace the Main Motor (M1).
Replace the Controller Board.
No
Remedy
Replace the Thermistor (TH1) or Fusing Unit.
Replace the Controller Board.
Yes
Replace the Thermistor (TH1) or Fusing Unit.
Replace the Controller Board.
Yes
95