3. Remove the two mounting screws.
4. Pressing the right and left tabs (at two places), separate the upper half of the Fusing Unit from
the lower half.
5. Remove the bushings and the Backup Roller.
6. Remove the Fusing Entrance Guide.
(a) Push the Fusing Entrance Guide to the left.
(b) Pull out the right end of the Fusing Entrance Guide.
(c) Pull out the left end of the Fusing Entrance Guide.
Fusing Entrance
Guide
PagePro 1200 Series Maintenance / Disassembly
Backup Roller
(a)
(c)
(b)
77
4127s047
Bushing
4127s048