4
. LUBRICATION SYSTEM
ENGINE OIL/OIL FILTER
OIL LEVEL
*
Place the motorcycle upright on
•
level ground for engine oil level check.
Run the engine for 2_
•
minutes and check the oil level after the
engine is stopped for 2_
Remove the oil dipstick and check the oil
level with the oil dipstick.
If the level is near the lower level, fill to the
upper level with the specified engine oil.
OIL CHANGE
*
The engine oil will drain more easily
while the engine is warm.
Remove the oil filter screen cap located on the
bottom of the engine to drain the engine oil
thoroughly.
After the oil has been completely drained,
check the filter screen O-ring for damage and
replace if necessary.
Install the oil filter screen, spring and filter
screen cap.
Torque: 1.5kg-m
Fill with the specified SAE15W40#, API:
SG/CD engine oil to the proper level.
Oil Capacity: At disassembly : 0.90 liter
At change
Check for oil leaks and then start the engine
and let it idle for few minutes.
Recheck the oil level.
OIL PUMP
REMOVAL
Remove the A.C. generator flywheel. ( 14-7)
Remove the nine right crankcase cover bolts
and the right crankcase cover.
4-3
www.PlanDeGraissage.org
3
3 minutes.
: 0.75 liter
PEOPL E 125/150
Lower Level
Upper Level
Oil Dipstick
Oil Filter Screen Cap
Bolts
Stator
Right Crankcase Cover
Pulser Coil