INSTALLATION REQUIREMENTS

Tools and Parts

Gather the required tools and parts before starting installation.
Read and follow the instructions provided with any tools listed
here.
Tools needed:
These washers must be installed by professional installers. The
installer should have a full compliment of standard SAE and
metric hand tools as well as other specialized tools as required.
Additional materials required:
Additional materials required vary with the type of installation.
The customer is responsible for supplying additional hardware
and adapters as necessary.
Parts supplied:
Remove parts bag from washer drum. Check that all parts were
included. The number of parts supplied varies with model.
Molded rubber drain hose and band clamp
Rubber washers for the hoses (4 or 6)
Water supply hoses (2 or 3)

Optional Equipment

The following optional equipment is available for these washers.
Steam Heater Kit
Steam heating kits are available for Model MFS55 only.
To add a steam kit to your washer, order the kit specified in the
table below:
Model
MFS55PNA
Steam Kit Number
W10308483

Location Requirements

Washers should be installed on a level concrete floor on the
ground level of a building; they can also be installed on an
elevated concrete pad up to 12" (300 mm) above the surrounding
floor. Consult a structural engineer to approve other locations.
The 18 and 25 lb. washers can also be mounted on an elevated
metal base up to 12" (300 mm) high.
Proper installation is your responsibility. The installation must
meet all governing codes and ordinances.
You will need:
The washer should be located in a building and not directly
exposed to the weather. The temperature of the building
should be 40–95°F (5–35°C) during operation.
A hot water heater set between 120–160°F (49–80°C).
Valved hot and cold water supply (3/4" male NPT fitting)
within 4 ft. (1.2 m) of the washer with a water pressure
between 43 and 73 PSI (0.3–0.5 MPa).
A dedicated, GFCI-equipped circuit for each washer (see
"Electrical Requirements").
Adequate sanitary sewer drainage located behind the
washers.
A solid concrete floor or slab capable of withstanding the
weight and vibration produced by the washer. The maximum
slope of the floor is 1" (25 mm) under the washer. A rough
concrete surface is preferable to a smooth or covered
surface when the washer is not secured, to keep the washer
from walking during extraction cycles.
Minimum Installation Clearances:
The location must be large enough to allow the washer door to
open completely.
There should be adequate access behind and above the
washer for maintenance and service.
3