Trane GAM5B0A18M11EB Installation, Operation And Maintenance Manual page 42

Convertible air handlers
Table of Contents

Advertisement

Heater
Model
No.
No Heater
BAYEAAC04BK1
BAYEAAC04LG1
BAYEAAC05BK1
BAYEAAC05LG1
BAYEAAC08BK1
BAYEAAC08LG1
BAYEAAC10BK1
BAYEAAC10LG1
BAYEAAC10LG3
BAYEABC15LG3
BAYEABC15BK1 - Circuit 1①
BAYEABC15BK1 - Circuit 2
BAYEABC20BK1 - Circuit 1①
BAYEABC20BK1 - Circuit 2
BAYEACC25BK1 - Circuit 1①
BAYEACC25BK1 - Circuit 2
BAYEACC25BK1 - Circuit 3
Note: * Motor Amps
① MCA and MOP for circuit 1 contains the motor amps
Heater
Model
No.
No Heater
BAYEAAC04BK1
BAYEAAC04LG1
BAYEAAC05BK1
BAYEAAC05LG1
BAYEAAC08BK1
BAYEAAC08LG1
BAYEAAC10BK1
BAYEAAC10LG1
BAYEAAC10LG3
BAYEABC15LG3
BAYEABC15BK1 - Circuit 1①
BAYEABC15BK1 - Circuit 2
BAYEABC20BK1 - Circuit 1①
BAYEABC20BK1 - Circuit 2
BAYEACC25BK1②③- Circuit 1①
BAYEACC25BK1 - Circuit 2
BAYEACC25BK1 - Circuit 3
Note: * Motor Amps
① MCA and MOP for circuit 1 contains the motor amps
② If the air handler is applied in downflow or horizontal configurations, the airflow should not exceed 2000 CFM. Airflow above 2000 CFM could
result in water blow-off.
③ Tap 5 can be used but only when the external static pressure is .6" or above.
42
No.
Heater
Capacity
of
Amps
Circuits
kW
BTUH
Circuit
-
-
-
1
3.84
13100
16.0
1
4.80
16400
20.0
1
7.68
26200
32.0
1
9.60
32800
40.0
1-3 PH
9.60
32800
23.1
1-3 PH
14.40
49200
34.6
9.60
32800
2
4.80
16400
9.60
32800
2
9.60
32800
9.60
32800
3
9.60
32800
4.80
16400
No.
of
Capacity
Circuits
kW
BTUH
-
-
-
1
3.84
13100
1
4.80
16400
1
7.68
26200
1
9.60
32800
1-3 PH
9.60
32800
1-3 PH
14.40
49200
9.60
32800
2
4.80
16400
9.60
32800
2
9.60
32800
9.60
32800
3
9.60
32800
4.80
16400
WIRING DATA
GAM5B0C48M41EB
240 VOLT
Minimum
Maximum
Circuit
Overload
per
Ampacity
Protection
6.0*
8
15
28
30
33
35
48
50
58
60
36
40
50
50
40
58
60
20
25
25
40
58
60
40
50
50
40
58
60
40
50
50
20
25
25
WIRING DATA
GAM5B0C60M51EB
240 VOLT
Heater
Minimum
Maximum
Amps
Circuit
Overload
per
Ampacity
Protection
Circuit
7.6*
10
15
16.0
30
30
20.0
35
35
32.0
50
50
40.0
60
60
23.1
37
40
34.6
52
60
40
60
60
20
25
25
40
60
60
40
50
50
40
60
60
40
50
50
20
25
25
208 VOLT
Heater
Minimum
Capacity
Amps
Circuit
per
Ampacity
kW
BTUH
Circuit
-
-
6.0*
2.88
9800
13.8
3.60
12300
17.3
5.76
19700
27.7
7.20
24600
34.6
7.20
24600
20.0
10.80
36900
30.0
7.20
24600
34.6
3.60
12300
17.3
7.20
24600
34.6
7.20
24600
34.6
7.20
24600
34.6
7.20
24600
34.6
3.60
12300
17.3
208 VOLT
Heater
Minimum
Capacity
Amps
Circuit
per
Ampacity
Circuit
kW
BTUH
-
-
7.6*
2.88
9800
13.8
3.60
12300
17.3
5.76
19700
27.7
7.20
24600
34.6
7.20
24600
20.0
10.80
36900
30.0
7.20
24600
34.6
3.60
12300
17.3
7.20
24600
34.6
7.20
24600
34.6
7.20
24600
34.6
7.20
24600
34.6
3.60
12300
17.3
Maximum
Overload
Protection
8
15
25
25
29
30
42
45
51
60
32
35
44
45
51
60
22
25
51
60
43
45
51
60
43
45
22
25
Maximum
Overload
Protection
10
15
27
30
31
35
44
45
53
60
34
35
46
50
53
60
22
25
53
60
43
45
53
60
43
45
22
25

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents