Trane GAM5B0A18M11EB Installation, Operation And Maintenance Manual page 39

Convertible air handlers
Table of Contents

Advertisement

EXTERNAL STATIC
(in w.g)
0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
NOTES:
1. Values are with wet coil and without filters.
2. Contact your particular filter manufacturer for pressure drop data.
3. Electric heater pressure drop is negligible and is included within the airflow data.
4. Tap 1 is an continuous fan speed tap for single stage systems. Airflow adjustment is required for 2 stage systems.
See Airflow adjustment section.
5. If the air handler is applied in downflow or horizontal configurations, the airflow should not exceed 2000 CFM.
Airflow above 2000 CFM could result in water blow-off.
6. † Factory Setting
GAM5B0C60M51SB, GAM5B0C60M51EA MINIMUM HEATER AIRFLOW CFM
Heater
BAYEAAC04BK1
BAYEAAC04LG1
BAYEAAC05BK1
BAYEAAC05LG1
BAYEAAC08BK1
BAYEAAC08LG1
BAYEAAC10BK1
BAYEAAC10LG1
BAYEAAC10LG3
BAYEABC15BK1
BAYEABC15LG3
BAYEABC20BK1
BAYEACC25BK1
① If the air handler is applied in downflow or horizontal configurations, the airflow should
not exceed 2000 CFM. Airflow above 2000 CFM could result in water blow-off.
② Tap 5 can be used but only when the external static pressure is .6" or above.
Note: Heating and cooling speeds are the same, factory set at Speed Tap #4.
Note: A "G" only signal from the comfort control will run the blower at a lower speed, factory
set at Speed Tap #1. See the Sequence of Operation for additional information.
Note: Speed Tap 1 is NOT used for two stage systems. Two stage systems will require an
airflow adjustment.
AIRFLOW PERFORMANCE
GAM5B0C60M51EB
Speed Taps - 230 VOLTS
5
4 †
3
2327
2020
1914
2285
1980
1873
2237
1944
1835
2182
1908
1800
2125
1869
1756
2062
1830
1717
1995
1747
1664
1922
1707
1629
1844
1673
1594
1761
1629
1553
Minimum Air Speed Tap
Without HP
Tap 2
Tap 2
Tap 2
Tap 2
Tap 2
Tap 3
Tap 3
Tap 3
Tap 4
AIRFLOW (CFM)
2
1
5
1819
1125
2324
1780
990
2279
1740
831
2228
1705
600
2171
1659
331
2111
1620
249
2045
1575
187
1975
1540
-
1899
1502
-
1819
1464
-
1733
With HP
Tap 3
Tap 3
Tap 3
Tap 3
Tap 3
Tap 4
Tap 4
Tap 4
①②
Tap 5
Speed Taps - 208 VOLTS
4 †
3
2
2017
1910
1816
1974
1867
1774
1935
1826
1731
1896
1789
1693
1854
1742
1645
1813
1700
1603
1727
1644
1555
1685
1607
1518
1648
1569
1477
1601
1525
1436
1
1122
984
822
589
317
232
168
-
-
-
39

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents