Trane GAM5B0A18M11EB Installation, Operation And Maintenance Manual page 37

Convertible air handlers
Table of Contents

Advertisement

EXTERNAL STATIC
(in w.g)
0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
NOTES:
1. Values are with wet coil and without filters.
2. Contact your particular filter manufacturer for pressure drop data.
3. Electric heater pressure drop is negligible and is included within the airflow data.
4. Tap 1 is an continuous fan speed tap for single stage systems. Airflow adjustment is required for 2 stage systems.
See Airflow adjustment section.
5. † Factory Setting
GAM5B0C42M31SB, GAM5B0C42M31EA MINIMUM HEATER AIRFLOW CFM
Heater
BAYEAAC04BK1
BAYEAAC04LG1
BAYEAAC05BK1
BAYEAAC05LG1
BAYEAAC08BK1
BAYEAAC08LG1
BAYEAAC10BK1
BAYEAAC10LG1
BAYEAAC10LG3
BAYEABC15BK1
BAYEABC15LG3
BAYEABC20BK1
BAYEACC25BK1
Note: Heating and cooling speeds are the same, factory
set at Speed Tap #4.
Note: A "G" only signal from the comfort control will run
the blower at a lower speed, factory set at Speed Tap #1.
See the Sequence of Operation for additional information.
Note: Speed Tap 1 is NOT used for two stage systems.
Two stage systems will require an airflow adjustment.
AIRFLOW PERFORMANCE
GAM5B0C42M31EB
Speed Taps - 230 VOLTS
5
4 †
3
1644
1575
1401
1596
1525
1346
1550
1480
1300
1509
1437
1252
1463
1391
1205
1420
1345
1151
1376
1301
1085
1332
1251
1020
1271
1179
969
1199
1119
924
Minimum Air Speed Tap
Without HP
Tap 2
Tap 2
Tap 2
Tap 2
Tap 2
Tap 3
Tap 3
-
-
AIRFLOW (CFM)
2
1
5
1266
752
1641
1215
665
1590
1157
569
1542
1110
492
1497
1058
384
1449
980
327
1403
917
259
1356
865
-
1310
813
-
1246
747
-
1171
With HP
Tap 3
Tap 3
Tap 3
Tap 3
Tap 3
Tap 4
Tap 4
-
-
Speed Taps - 208 VOLTS
4 †
3
2
1572
1398
1263
1519
1340
1209
1471
1291
1148
1425
1241
1099
1377
1191
1043
1328
1134
963
1282
1066
898
1228
998
842
1154
944
788
1091
897
719
1
749
659
560
480
370
310
239
-
-
-
37