4.3

Inverter Storage

Proper storage is required if the inverter is not installed immediately.
Store the inverter in the original packing case with the desiccant inside.
The storage temperature must be always between -30℃ and +70℃, and the storage rel-
ative humidity must be always between 0 and 95 %, non-condensing.
In case of stacking storage, the number of stacking layers should never exceed the limit
marked on the outer side of the packing case.
The packing case should be upright.
If the inverter needs to be transported again, pack it strictly before loading and transport-
ing it.
Do not store the inverter in places susceptible to direct sunlight, rain, and strong electric
field.
Do not place the inverter in places with items that may affect or damage the inverter.
Store the inverter in a clean and dry place to prevent dust and water vapor from eroding.
Do not store the inverter in places with corrosive substances or susceptible to rodents
and insects.
Carry out periodic inspections. Inspection shall be conducted at least once every six
months. If any insect or rodent bites are found, replace the packaging materials in time.
If the inverter has been stored for more than a year, inspection and testing by professio-
nals are required before it can be put into operation.
Please store the inverter according to the storage requirements. Product damage
caused by failure to meet the storage requirements is not covered by the warranty.
4 Unpacking and Storage
33