3 Function Description
the maximum discharge current of the inverter (30A);
the maximum / recommended discharge current from the battery manufacturer.
For this reason, the battery discharge power may not reach the nominal power.
If the PV voltage is higher than 900 V, the battery cannot discharge.
The hybrid system will start to discharge the battery when the import power
value exceeds a threshold value of 70 W.
3.4

Communication and Configuration

The inverter possesses various ports for device and system monitoring, including RS485,
Ethernet, WLAN, and CAN; various parameters can be configured for optimal operation.
The inverter information is accessible through the iSolarCloud App.
3.5

EV Charger Management

The currently supported EV Charger brands and models are shown in the following table.
Brand
Model
SUN-
AC011E-01
GROW
30
Firmware Version
≥V1.2.469
User Manual