When you have selected the retry function, stay away from the motor and
machine unless required. They will start suddenly (after the reset time
has elapsed) after occurrence of an alarm.
When you have selected the retry function, apply the supplied CAUTION
seals in easily visible places.
Pr. 66 &
& Refer to Pr. 22.
& &
Pr. 70 &
& Refer to Pr. 30.
& &

" Applied motor (Pr. 71)

4.2.26 Applied motor (Pr. 71)
Pr. 71 "applied motor"
Set the motor used.
! When using the Mitsubishi constant-torque motor, set "1" in Pr. 71 for either V/F
control or general-purpose magnetic flux vector control.
The electronic overcurrent protection is set to the thermal characteristic of the
constant-torque motor.
Parameter
Number
71
<Setting>
! Refer to the following list and set this parameter according to the motor used.
Pr. 71
Setting
0, 100
Thermal characteristics matching a standard motor
Thermal characteristics matching the Mitsubishi
1, 101
constant-torque motor
3, 103
Standard motor
13, 113
Constant-torque motor
Mitsubishi general-
23, 123
purpose motor SF-
JR4P (1.5kW or less)
5, 105
Standard motor
15, 115
Constant-torque motor
6, 106
Standard motor
16, 116
Constant-torque motor
Factory
Setting
0, 1, 3, 5, 6, 13, 15, 16, 23, 100, 101,
0
103, 105, 106, 113, 115, 116, 123
Thermal Characteristics of Electronic
Overcurrent Protection
Select "offline auto tuning
setting".
Star
connection
Delta
connection
CAUTION
Related parameters
Pr. 0 "torque boost"
Pr. 12 "DC injection brake voltage"
Pr. 19 "base frequency voltage"
Pr. 80 "motor capacity"
Pr. 96 "auto-tuning setting/status"
Setting Range
Motor
constants can
be entered
directly.
98
PARAMETERS
Applied motor
Constant-
Standard
Torque
'
'
'
'
'
'
'
'
'