Service and maintenance
6.1
General notes about maintenance
Unintentional starting of the drive unit
Switch off the power supply to the drive unit.
Attach a warning notice to the start switch.
NOTICE
Improper maintenance
Only authorized qualified personnel may perform the maintenance and servicing. Only
original parts supplied by Siemens AG may be installed.
Only qualified personnel may perform the inspection, maintenance and servicing work.
Please observe the Specific safety instructions (Page 17).
6.2
Maintenance of the friction clutch
Note
Check the condition of the friction clutch initially after 500 operating hours and then at least
once yearly and after every blockage of the machine.
Note
Friction clutches with proximity switch are not suitable for ambient air temperatures under -
20 °C.
If the ambient temperatures differ, contact Technical Support.
If necessary, readjust the friction torque or replace the wearing parts, for example friction
lining and bushes. Replace the friction linings only as pair. We recommend replacing worn
bushes in sets.
BA 2039 (2KJ4)
Operating Instructions, 12/2022, A5E50009089A/RS-AJ
WARNING
6
39